Investigating the inherent safety designs of typical exothermic reaction processes

Author(s):  
Longfei Liu ◽  
Jun Liang ◽  
Jun-cheng Jiang ◽  
Lei Ni
Author(s):  
D.M. Vanderwalker

There is a fundamental interest in electrochemical fusion of deuterium in palladium and titanium since its supposed discovery by Fleischmann and Pons. Their calorimetric experiments reveal that a large quantity of heat is released by Pd after hours in a cell, suggesting fusion occurs. They cannot explain fusion by force arguments, nor can it be an exothermic reaction on the formation of deuterides because a smaller quantity of heat is released. This study examines reactions of deuterium in titanium.Both iodide titanium and 99% pure titanium samples were encapsulated in vacuum tubes, annealed for 2h at 800 °C. The Ti foils were charged with deuterium in a D2SO4 D2O solution at a potential of .45V with respect to a calomel reference junction. Samples were ion beam thinned for transmission electron microscopy. The TEM was performed on the JEOL 200CX.The structure of D charged titanium is α-Ti with hexagonal and fee deuterides.


2008 ◽  
Vol 36 (1) ◽  
pp. 63-79 ◽  
Author(s):  
L. Nasdala ◽  
Y. Wei ◽  
H. Rothert ◽  
M. Kaliske

Abstract It is a challenging task in the design of automobile tires to predict lifetime and performance on the basis of numerical simulations. Several factors have to be taken into account to correctly estimate the aging behavior. This paper focuses on oxygen reaction processes which, apart from mechanical and thermal aspects, effect the tire durability. The material parameters needed to describe the temperature-dependent oxygen diffusion and reaction processes are derived by means of the time–temperature–superposition principle from modulus profiling tests. These experiments are designed to examine the diffusion-limited oxidation (DLO) effect which occurs when accelerated aging tests are performed. For the cord-reinforced rubber composites, homogenization techniques are adopted to obtain effective material parameters (diffusivities and reaction constants). The selection and arrangement of rubber components influence the temperature distribution and the oxygen penetration depth which impact tire durability. The goal of this paper is to establish a finite element analysis based criterion to predict lifetime with respect to oxidative aging. The finite element analysis is carried out in three stages. First the heat generation rate distribution is calculated using a viscoelastic material model. Then the temperature distribution can be determined. In the third step we evaluate the oxygen distribution or rather the oxygen consumption rate, which is a measure for the tire lifetime. Thus, the aging behavior of different kinds of tires can be compared. Numerical examples show how diffusivities, reaction coefficients, and temperature influence the durability of different tire parts. It is found that due to the DLO effect, some interior parts may age slower even if the temperature is increased.


1986 ◽  
Vol 51 (6) ◽  
pp. 1259-1267
Author(s):  
Josef Horák ◽  
Petr Beránek

A simulation apparatus for the experimental study of the methods of control of batch reactors is devised. In this apparatus, the production of heat by an exothermic reaction is replaced by electric heating controlled by a computer in a closed loop; the reactor is cooled with an external cooler whose dynamic properties can be varied while keeping the heat exchange area constant. The effect of the cooler geometry on its dynamic properties is investigated and the effect of the cooler inertia on the stability and safety of the on-off temperature control in the unstable pseudostationary state is examined.


1984 ◽  
Vol 49 (11) ◽  
pp. 2566-2578 ◽  
Author(s):  
Josef Horák ◽  
Petr Beránek ◽  
Dagmar Maršálková

An algorithm is set up and tested for the temperature control of a batch reactor consisting in jump changes in the inlet temperature of entering coolant. This temperature is so chosen that its difference from the temperature of the reaction mixture is near the highest difference at which the stable pseudostationary state of the system still exists. For the prediction of the new coolant inlet temperature, a zero-order reaction model is used with an adaptive parameter estimated from the experimentally established value of the maximum of the reaction mixture overheating at the previous coolant temperature.


1982 ◽  
Vol 47 (2) ◽  
pp. 454-464 ◽  
Author(s):  
František Jiráček ◽  
Josef Horák

The effect has been studied of the inertia of the cooling system on the reliability of control of the temperature of the reaction mixture. The study has been made using a mathematical model of the batch reactor with an exothermic reaction. The temperature has been controlled by a two-level controller opening and closing the flow of the coolant. The aim of the control has been to maintain a constant value of the degree of utilization of the cooling capacity of the reactor. The instantaneous value of the degree of utilization has been assessed from the ratio of times for which the cooling system is idle to the time of operation. The reliability of control has been studied for variable activity of the catalyst.


1982 ◽  
Vol 47 (2) ◽  
pp. 446-453
Author(s):  
Josef Horák ◽  
František Jiráček ◽  
Libuše Ježová

A possibility has been tested in the paper of the feed back control of temperature of the reaction mixture in a batch reactor with an exothermic reaction through the variable area of the cooling surface. The measurement were carried out in a laboratory reactor with a retractable cooler which was being immersed into the reaction mixture. The speed of motion of the cooler was sufficiently high permitting the process of immersion to be regarded as practically instantaneous. The aim of the control was to stabilize the set point temperature of the reaction mixture by a two-point controler. In dependence on the rate of response of the system to a change of the section variable either the ideal relay or the relay with hysteresis control algorithmus were used. The results of measurements showed that with the aid of a retractable cooler the temperature could be controlled safely even in those cases, in which the control by the variable flow rate of the coolant was unfeasible. The verification was carried out in the open-loop instable operating point of the reactor.


2019 ◽  
Vol 3 (4) ◽  
pp. 519-530 ◽  
Author(s):  
Xiaoming Wang ◽  
Jing Peng ◽  
Xiaoliang Liang ◽  
Mengqiang Zhu ◽  
Bruno Lanson ◽  
...  

Sign in / Sign up