scholarly journals Contact damage of human dental enamel under cyclic axial loading with abrasive particles

Author(s):  
Estibaliz Sanchez-Gonzalez ◽  
Elena Pinilla-Cienfuegos ◽  
Oscar Borrero-Lopez ◽  
Fernando Rodríguez-Rojas ◽  
Fernando Guiberteau
Author(s):  
L. D. Ackerman ◽  
S. H. Y. Wei

Mature human dental enamel has presented investigators with several difficulties in ultramicrotomy of specimens for electron microscopy due to its high degree of mineralization. This study explores the possibility of combining ion-milling and high voltage electron microscopy as a means of circumventing the problems of ultramicrotomy.A longitudinal section of an extracted human third molar was ground to a thickness of about 30 um and polarized light micrographs were taken. The specimen was attached to a single hole grid and thinned by argon-ion bombardment at 15° incidence while rotating at 15 rpm. The beam current in each of two guns was 50 μA with an accelerating voltage of 4 kV. A 20 nm carbon coating was evaporated onto the specimen to prevent an electron charge from building up during electron microscopy.


Author(s):  
M. John Hicks

Acid-etching of enamel surfaces has been performed routinely to bond adhesive resin materials to sound dental enamel as a caries-preventive measure. The effect of fluoride pretreatment on acid-etching of enamel has been reported to produce inconsistent and unsatisfactory etching patterns. The failure to obtain an adequate etch has been postulated to be due to fluoride precipitation products deposited on the enamel surface. The purpose of this study was to evaluate the effects of fluoride pretreatment on acid-etching of carieslike lesions of human dental enamel.Caries-like lesions of enamel were created in vitro on human molar and premolar teeth. The teeth were divided into two fluoride treatment groups. The specimens were exposed for 4 minutes to either a 2% Sodium Fluoride (NaF) solution or a 10% Stannous Fluoride (SnF2) solution. The specimens were then washed in deionized-distilled water. Each tooth was sectioned into four test regions. This was carried out to compare the effects of various time exposures (0 to 2 minutes) and differing concentrations (10 to 60% w/w) of phosphoric acid (H3PO4) on etching of caries-like lesions. Standard preparation techniques for SEM were performed on the specimens.


Author(s):  
T. L. Hayes

Biomedical applications of the scanning electron microscope (SEM) have increased in number quite rapidly over the last several years. Studies have been made of cells, whole mount tissue, sectioned tissue, particles, human chromosomes, microorganisms, dental enamel and skeletal material. Many of the advantages of using this instrument for such investigations come from its ability to produce images that are high in information content. Information about the chemical make-up of the specimen, its electrical properties and its three dimensional architecture all may be represented in such images. Since the biological system is distinctive in its chemistry and often spatially scaled to the resolving power of the SEM, these images are particularly useful in biomedical research.In any form of microscopy there are two parameters that together determine the usefulness of the image. One parameter is the size of the volume being studied or resolving power of the instrument and the other is the amount of information about this volume that is displayed in the image. Both parameters are important in describing the performance of a microscope. The light microscope image, for example, is rich in information content (chemical, spatial, living specimen, etc.) but is very limited in resolving power.


MedPharmRes ◽  
2019 ◽  
Vol 2 (4) ◽  
pp. 15-19
Author(s):  
Son Nguyen ◽  
Son Vi ◽  
Hoat Luu ◽  
Toan Do

There are cases when symptoms are available but no abnormal stenosis is found in MRI and vice versa. Axial-loaded MRI has been shown that it can demonstrate more accurately the real status of spinal canal stenosis than conventional MRI. This is the first time we applied a new system that we have recreated from the original loading frame system in order to fit with the demands of Vietnamese people. Sixty-two patients were selected from Phu Tho Hospital in Phu Tho Province, Vietnam, who fulfilled the inclusion criteria. The Anterior-posterior diameter (APD), Dura Cross-sectional Area (DSCA) in conventional MRI and axial loaded MRI, and changes in APD and DCSA were determined at the single most constricted intervertebral level. The APD and DCSA in axial loaded MRI had very good significant correlations with VAS for back pain (rs=0.83, 0.79), leg pain (rs=0.69, 0.57) and JOA score (rs=0.70, 0.65). APD and DCSA in axial loaded MRI significantly correlated with the severity of symptoms. Our axial loading MRI provides more valuable information than the conventional MRI for assessing patients with LSCS.


2016 ◽  
Vol 3 (2) ◽  
Author(s):  
Mashkoor Ahmad Lone ◽  
Dr. P. Ganesan

The practice of placing deprived children having least or no emotional and material resources, in orphanages has since long been prevailing in socio -economically poor Asian countries. A sample of 30 children residing in orphanage in district Anantnag in the age group of 13-18 years was selected for the present study. Most of the children were found socially and psychologically disturbed. As per Indian Academy Paediatrics (IAP) classification with respect to weight for age the condition was not bad that as approximately 67% percent of the children were found to be normal. In the same way height for age as per Waterloo’s classification shown that more than half of the children were normal. On clinical examination approximately 47% of children were normal, while as rest were suffering from dispigmentation of hair, moon face, xerosis of skin cheilosis, magenta tongue, spongy bleeding gums, oedema, conjuctival xerosis, and mottled dental enamel. The findings indicated that nutritional intake was deficient for all nutrients when compared to, Recommended Daily Allowances Chart (RDA) for all age groups which may be linked to poor planning of menus in orphanages.


2020 ◽  
Vol 1 (2) ◽  
Author(s):  
Aditya Nugraha ◽  
Masri Bin Ardin

PVDF sensor is a sensor that is often used to measure force, strain, vibration and heat. In this study, PVDF sensors with surface polarization are used to detect cutting forces on the machine. The PVDF sensor that has been polarized on the surface is placed in the chuck part of the engine. Measuring instrumen for testing and calibrating PVDF sensors is oscilloscope with increased loading and reduced axial and tangential directions. After the calibration process, the PVDF sensor was used to measure cutting force on drilling machine, and then the results were compared with the PCB piezotronics force sensor. The PVDF sensor output signal is measured and studied for its voltage using an oscilloscope, where the output signal is compared to the weight given to the PVDF sensor. From the results of these tests indicate that the maximum deviation in axial loading is 0.32V while the tangential loading is 0.31VKeywords. PVDF sensor, Surface polarization, Drilling machine, Cutting force


2018 ◽  
Vol 69 (10) ◽  
pp. 2913-2915
Author(s):  
Daniela Jumanca ◽  
Anamaria Matichescu ◽  
Atena Galuscan ◽  
Laura Cristina Rusu ◽  
Cornelia Muntean

This experimental study aims to analyse the effectiveness of various materials used in demineralisation of dental enamel. This work aims to create a mechanical bond by filling the pegs with sealing material. In order to achieve this goal, five teeth were compared using different concentrations of orthophosphoric acid and exposure times. In this regard, five different tests were performed and the results were analysed using the SEM technique (scanning electron microscopy). These comparative analyses revealed that etching using 35% orthophosphoric acid for one minute and etching using Icon Etch for two minutes were the most effective.


Sign in / Sign up

Export Citation Format

Share Document