Eco-friendly chiral HPLC method for determination of alfuzosin enantiomers and solifenacin in their newly pharmaceutical combination: Method optimization via central composite design

2021 ◽  
Vol 165 ◽  
pp. 106095
Author(s):  
Mina Wadie ◽  
Ezzat M. Abdel-Moety ◽  
Mamdouh R. Rezk ◽  
Mahmoud A. Tantawy
2017 ◽  
Vol 9 (10) ◽  
pp. 1665-1671 ◽  
Author(s):  
Samira Yousefi ◽  
Marzieh Kamankesh ◽  
Sahar Jazaeri ◽  
Abdolmohammad Attaran ◽  
Abdorreza Mohammadi

A rapid, simple and highly sensitive analytical method based on a microextraction method, followed by high-performance liquid chromatography was developed for the determination of caffeine in different tea and energy drink samples.


Author(s):  
Ajay I. Patel ◽  
Krupa B. Prajapati ◽  
Swati H. Jolapara ◽  
Amitkumar J. Vyas ◽  
Ashok B. Patel ◽  
...  

The high-Performance Analytical Liquid Chromatography (HPLC) method (AQbD) for routine analysis of Gemfibrozil in dosage form was developed in column C18 using an experimental design. The central composite design (CCD) was adopted in evaluating the responses and robustness of the method. In the project, the combined effect of buffer pH, % organic phase and flow rate, each at five levels, was selected for responses such as retention time and number of theoretical plates, then interpreted and optimized statistically with the help of the surface methodology of response and therefore of the analysis of the constructed models and of the outline graphs was obtained. Acetonitrile: phosphate buffer (pH-4) (59: 41% v / v) as eluent at a flow rate of 1.0ml/min was found to be the optimal condition for obtaining the desired answers.


Separations ◽  
2021 ◽  
Vol 8 (1) ◽  
pp. 5
Author(s):  
Mohd Afzal ◽  
Mohd. Muddassir ◽  
Abdullah Alarifi ◽  
Mohammed Tahir Ansari

A highly specific, accurate, and simple RP-HPLC technique was developed for the real-time quantification of domperidone (DOMP) and lansoprazole (LANS) in commercial formulations. Chromatographic studies were performed using a Luna C8(2), 5 μm, 100Å, column (250 × 4.6 mm, Phenomenex) with a mobile phase composed of acetonitrile/2 mM ammonium acetate (51:49 v/v), pH 6.7. The flow rate was 1 mL·min−1 with UV detection at 289 nm. Linearity was observed within the range of 4–36 µg·mL−1 for domperidone and 2–18 µg·mL−1 for lansoprazole. Method optimization was achieved using Box-Behnken design software, in which three key variables were examined, namely, the flow rate (A), the composition of the mobile phase (B), and the pH (C). The retention time (Y1 and Y3) and the peak area (Y2 and Y4) were taken as the response parameters. We observed that slight alterations in the mobile phase and the flow rate influenced the outcome, whereas the pH exerted no effect. Method validation featured various ICH parameters including linearity, limit of detection (LOD), accuracy, precision, ruggedness, robustness, stability, and system suitability. This method is potentially useful for the analysis of commercial formulations and laboratory preparations.


INDIAN DRUGS ◽  
2015 ◽  
Vol 52 (11) ◽  
pp. 42-49
Author(s):  
C Dhal ◽  
◽  
F. J. Ahmad ◽  
M. Singhal ◽  
A. Kukrety ◽  
...  

An accurate, sensitive, precise, economic and rapid isocratic Reverse Phase High Performance Liquid Chromatography method was developed complying Quality by Design (QbD) trends and validated for determining doxycycline hyclate in bulk drug, tablet and capsule dosage form. The method was optimized using Minitab software with 3 factors (pH of the buffer, flow rate and percentage of buffer in the mobile phase), 2 level (higher limit and lower limit) Central Composite Design (CCD). The results of randomized 20 runs were analyzed for optimum composite desirability to give optimum conditions such as, pH 6.5, flow rate 0.9 mLmin-1 and 30:70 V/V 0.05M potassium dihydrogen orthophosphate buffer adjusted to pH 6.5 using orthophosphoric acid and methanol using C8 column 250 X 4.6 mm X 5.0 μm, injection volume of 10uL, ambient column temperature and ultraviolet detection using photo diode array detector at 360nm as constants. The method was validated as per ICH guidelines and was found linear over a concentration range of 10-100 μg/mL (r2 = 0.999) with the limits of detection and quantification being 2.45 μg/mL and 7.55 μg/mL respectively.


2019 ◽  
Vol 32 (1) ◽  
pp. 69-72
Author(s):  
T. Naga Jhansi ◽  
D. Pavan Kumar ◽  
Nagaraju Rajana ◽  
D. Jayadeep Kumar ◽  
G. Nageswara Rao

A reverse phase chiral HPLC method was developed for the determination of (R)-2-aminobutanamide isomer content in (S)-2-amino-butanamide key starting material for levetiracetam drug substance by using a CROWNPAK CR (+) column. Perchloric acid solution (0.05 %) was used as mobile phase and the flow rate was finalized as 0.3 mL/min. UV detection wavelength was 200 nm and column temperature was set as 15 ºC. The limit of detection and limit of quantification were 0.0002 mg/mL and 0.0005 mg/mL, respectively. The linearity calibration curve of (R)-2-aminobutanamide was shown good from the range of 0.0005 mg/mL to 0.004 mg/mL. The recovery of (R)-2-aminobutanamide isomer was between the range of 93 to 106 % in presence of (S)-2-aminobutanamide. The method was validated and found to be precise, accurate and robust. The method can be used for determination of (R)-2-aminobutanamide in presence of (S)-2-aminobutanamide, which is the key intermediate for preparation of levetiracetam. This method was validated in as per ICH Q2 (R1) and USP validation of compendial methods (1225).


2006 ◽  
Vol 65 (1-2) ◽  
pp. 81-84 ◽  
Author(s):  
P. Madhavan ◽  
B. M. Rao ◽  
Pravin ◽  
Abhishek ◽  
P. R. Kumar ◽  
...  

Sign in / Sign up