pH sensitive composite hydrogels based on gelatin and reinforced with cellulose microcrystals: In depth physicochemical and microstructural analyses for controlled release of vitamin B2

2021 ◽  
Vol 27 ◽  
pp. 102334
Author(s):  
Soumaya Boughriba ◽  
Nabil Souissi ◽  
Rim Nasri ◽  
Moncef Nasri ◽  
Suming Li
2015 ◽  
Vol 3 (13) ◽  
pp. 2685-2697 ◽  
Author(s):  
Xinyu Hu ◽  
Wei Wei ◽  
Xiaoliang Qi ◽  
Hao Yu ◽  
Liandong Feng ◽  
...  

The pH-sensitive swelling behaviour and DOX release of Salecan-g-PAA hydrogels are discussed.


2015 ◽  
Vol 26 (10) ◽  
pp. 1203-1208 ◽  
Author(s):  
Yu-Jie Chang ◽  
Xi-Zhen Liu ◽  
Qing Zhao ◽  
Xiao-Hai Yang ◽  
Ke-Min Wang ◽  
...  

RSC Advances ◽  
2021 ◽  
Vol 11 (48) ◽  
pp. 29986-29996
Author(s):  
Xiuxiu Qi ◽  
Hongmei Yan ◽  
Yingxue Li

A pH-sensitive core–shell nanoparticle (HMS@C18@PSDMA-b-POEGMA) was developed via a self-assembly process as the carrier of anticancer drug doxorubicin (DOX) for drug loading and controlled release.


Polymers ◽  
2018 ◽  
Vol 10 (9) ◽  
pp. 1009 ◽  
Author(s):  
Ko-Shao Chen ◽  
Shu-Ju Chang ◽  
Chi-Kuang Feng ◽  
Win-Li Lin ◽  
Shu-Chuan Liao

When stainless steel is implanted in human bodies, the corrosion resistance and biocompatibility must be considered. In this study, first, a protective organic silicone film was coated on the surface of stainless steel by a plasma deposition technique with a precursor of hexamethyldisilazane (HMDSZ). Then, ultraviolet (UV) light-induced graft polymerization of N-isopropylacrylamide (NIPAAm) and acrylic acid (AAc) in different molar ratios were applied onto the organic silicone film in order to immobilize thermos-/pH-sensitive composite hydrogels on the surface. The thermo-/pH-sensitive composite hydrogels were tested at pH values of 4, 7.4 and 10 of a phosphate buffer saline (PBS) solution at a fixed temperature of 37 °C to observe the swelling ratio and drug delivery properties of caffeine which served as a drug delivery substance. According to the results of Fourier Transformation Infrared (FTIR) spectra and a potential polarization dynamic test, the silicone thin film formed by plasma deposition not only improved the adhesion ability between the substrate and hydrogels but also exhibited a high corrosion resistance. Furthermore, the composite hydrogels have an excellent release ratio of up to 90% of the absorbed amount after 8h at a pH of 10. In addition, the results of potential polarization dynamic tests showed that the corrosion resistance of stainless steel could be improved by the HMDSZ plasma deposition.


2022 ◽  
Vol 276 ◽  
pp. 115531
Author(s):  
Marwa Sta ◽  
Dayane B. Tada ◽  
Simone F. Medeiros ◽  
Amilton M. Santos ◽  
Nicole R. Demarquette

Sign in / Sign up

Export Citation Format

Share Document