Light yield, long-term stability, and attenuation length of a new plastic scintillator cured at room temperature

Author(s):  
E. Saito ◽  
H. Miyata ◽  
M. Katsumata ◽  
Y. Karasawa ◽  
T. Koike ◽  
...  
Solar Energy ◽  
2021 ◽  
Vol 218 ◽  
pp. 28-34
Author(s):  
Mahmoud Samadpour ◽  
Mahsa Heydari ◽  
Mahdi Mohammadi ◽  
Parisa Parand ◽  
Nima Taghavinia

1987 ◽  
Vol 97 ◽  
Author(s):  
K. A. Gschneidner ◽  
J. F. Nakahara ◽  
B. J. Beaudry ◽  
T. Takeshita ◽  
Ames Laboratory

ABSTRACTThe phase relationships and the important structural, electrical and thermal properties of the R3X4-R2X3 (where R = lanthanides and X = S, Se and Te) phases having the Th3P4 -type structure are reviewed. The room temperature electrical resistivity and Seebeck coefficient of these materials are independent of R and only slightly dependent on X, but critically dependent on the X:R ratio. The long term stability of these phases is also reviewed. Although these materials have good thermoelectric properties there are some problems which need to be solved before these phases can be utilized in thermoelectric devices. These problems include long term stability, higher than desirable thermal conductivities, and low electron mobilities.


2019 ◽  
Vol 55 (3) ◽  
pp. 188-192
Author(s):  
M. L. Colsoul ◽  
A. Breuer ◽  
N. Goderniaux ◽  
J. D. Hecq ◽  
L. Soumoy ◽  
...  

Background and Objective: Infusion containing lorazepam is used by geriatric department to limit anxiety disorders in the elderly. Currently, these infusions are prepared according to demand by the nursing staff, but the preparation in advance in a centralized service could improve quality of preparation and time management. The aim of this study was to investigate the long-term stability of this infusion in polypropylene syringes stored at 5 ± 3°C. Then, results obtained were compared with stability data of lorazepam in syringes stored at room temperature, glass bottles at 5 ± 3°C, and glass bottles at room temperature. Method: Eight syringes and 6 bottles of infusion were prepared by diluting 1 mL lorazepam 4 mg in 23 mL of NaCl 0.9% under aseptic conditions. Five syringes and 3 bottles were stored at 5 ± 3°C and 3 syringes and 3 bottles were stored at room temperature for 30 days. During the storage period, particle appearance or color change were periodically checked by visual and microscope inspection. Turbidity was assessed by measurements of optical density (OD) at 3 wavelengths (350 nm, 410 nm, 550 nm). The stability of pH was also evaluated. The lorazepam concentrations were measured at each time point by high-performance liquid chromatography with ultraviolet detector at 220 nm. Results: Solutions were physically unstable in syringes at 5 ± 3°C after 4 days: crystals and a drop of OD at 350 nm were observed. However, pH was stable. After 2 days, solutions were considered as chemically unstable because a loss of lorazepam concentration higher than 10% was noticed: the lower 1-sided confidence limit at 95% was below 90% of the initial concentration. To assess temperature and polypropylene influence, results were compared with those obtained for syringes at room temperature and bottles at 5 ± 3°C and room temperature. Precipitation, drop of OD at 350 nm, and chemical instability were observed in all conditions. Conclusion: Solutions of lorazepam were unstable after 2 days in syringes at 5 ± 3°C. Preparation in advance appears, therefore, not possible for the clinical use. Storage conditions (temperature and form) do not improve the stability.


2021 ◽  
Author(s):  
Mingli Chen ◽  
Sun Jiaojiao ◽  
Tongkuo Yuan ◽  
Jian Yin ◽  
Huancai Yin

As a good substrate, gold has been widely applied in the fields of biological diagnosis and biological analysis. By forming Au-S bonds, the self-assembled molecules could form a monolayer modification...


2017 ◽  
Vol 5 (12) ◽  
pp. 3065-3071 ◽  
Author(s):  
Linzhong Wu ◽  
Jiaqi Yu ◽  
Lei Chen ◽  
Di Yang ◽  
Shumin Zhang ◽  
...  

A general and fast approach has been developed to transfer any hydrophobic nanocrystals into water within several seconds without vigorous stirring or ultrasonication treatment at room temperature by using a bi-soluble solvent through the classical “like dissolves like” rule.


2020 ◽  
Vol 325 ◽  
pp. 128810 ◽  
Author(s):  
Zhimin Gao ◽  
Guoshuai Song ◽  
Xuemin Zhang ◽  
Qian Li ◽  
Shuang Yang ◽  
...  

Author(s):  
Theresa Winter ◽  
Anne Greiser ◽  
Matthias Nauck ◽  
Astrid Petersmann

AbstractLong transportation times of samples can occur due to centralization of laboratories, and also in, for instance epidemiological multicenter studies with one core laboratory. Unsatisfactory glycolysis inhibition is known to threaten the correct measurements of glucose concentration in patient samples. In former studies Terumo Glycaemia tubes proved to be superior to other anticoagulant systems for time periods of up to 24 h. We investigated long-term stability of glucose concentration in Terumo Glycaemia tubes for up to 96 h at room temperature and imitated transport conditions by continuous sample shaking.Human venous blood samples were collected from 40 healthy blood donors using Terumo Glycaemia tubes. Immediately after sampling, tubes were mixed according to the manufactures recommendations. To simulate transportation conditions samples were placed on a shaker for the entire study period and maintained at room temperature. Samples were (re)centrifuged at 0, 24, 36, 48, 72 and 96 h prior to measuring glucose concentration. The glucose concentration at 0 h was used as baseline for evaluation of long-term stability.The recovery of glucose was 100% throughout the study, including the 96-h measurements. Deviations of single glucose measurements were within the imprecision of the measurement procedure.Terumo Glycaemia tubes can effectively stabilize glucose in whole blood samples kept at room temperature on a shaker during a 96-h time period. Therefore, we consider Terumo Glycaemia tubes as a suitable glucose stabilizing tube for long intervals between sample collection and glucose quantification.


Sign in / Sign up

Export Citation Format

Share Document