scholarly journals Lateral flow immunoassay and enzyme linked immunosorbent assay as effective immunomethods for the detection of synthetic cannabinoid JWH-200 based on the newly synthesized hapten

2018 ◽  
Vol 5 ◽  
pp. 65-75 ◽  
Author(s):  
Lucie Fojtíková ◽  
Anna Šuláková ◽  
Martina Blažková ◽  
Barbora Holubová ◽  
Martin Kuchař ◽  
...  
2020 ◽  
Vol 58 (9) ◽  
Author(s):  
Katharina Ziegler ◽  
Anca Rath ◽  
Christoph Schoerner ◽  
Renate Meyer ◽  
Thomas Bertsch ◽  
...  

ABSTRACT Diagnosis of Lyme neuroborreliosis (LNB) is challenging, as long as Borrelia-specific intrathecal antibodies are not yet detectable. The chemokine CXCL13 is elevated in the cerebrospinal fluid (CSF) of LNB patients. Here, we compared the performances of the Euroimmun CXCL13 enzyme-linked immunosorbent assay (CXCL13 ELISA) and the ReaScan CXCL13 lateral flow immunoassay (CXCL13 LFA), a rapid point-of-care test, to support the diagnosis of LNB. In a dual-center case-control study, CSF samples from 90 patients (34 with definite LNB, 10 with possible LNB, and 46 with other central nervous system [CNS] diseases [non-LNB group]) were analyzed with the CXCL13 ELISA and the CXCL13 LFA. Classification of patients followed the European Federation of Neurological Societies (EFNS) guidelines on LNB. The CXCL13 ELISA detected elevated CXCL13 levels in all patients with definite LNB (median, 1,409 pg/ml) compared to the non-LNB controls (median, 20.7 pg/ml; P < 0.0001), with a sensitivity of 100% and a specificity of 84.8% (cutoff value, 78.6 pg/ml; area under the receiver operating characteristic [ROC] curve, 0.93). Similarly, the CXCL13 LFA yielded elevated CXCL13 levels in 31 patients with definite LNB (median arbitrary value, 223.5) compared to the non-LNB control patients (median arbitrary value, 0; P < 0.0001) and had a sensitivity and specificity of 91.2% and 93.5%, respectively (cutoff arbitrary value, 22.5; area under the ROC curve, 0.94). The correlation between the CXCL13 levels obtained by ELISA and LFA was strong (Spearman correlation coefficient r = 0.89; P < 0.0001). The CXCL13 ELISA and the CXCL13 LFA are comparable diagnostic tools for the detection of CXCL13 in the CSF of patients with definite LNB. The advantage of the CXCL13 LFA is the shorter time to result.


2021 ◽  
Author(s):  
Chuanlai Xu ◽  
xin guo ◽  
lu lin ◽  
Shanshan Song ◽  
aihong wu ◽  
...  

The abuse of dapsone (DDS) in food animals could result in its accumulation in humans through the food chain thus endangering human health. A sensitive monoclonal antibody (mAb) against DDS...


2019 ◽  
Vol 9 (1) ◽  
Author(s):  
Tsung-Ting Tsai ◽  
Tse-Hao Huang ◽  
Natalie Yi-Ju Ho ◽  
Yu-Pei Chen ◽  
Chung-An Chen ◽  
...  

Abstract The diagnosis of periprosthetic joint infection (PJI) remains a challenge. However, recent studies showed that synovial fluid biomarkers have demonstrated greater diagnostic accuracy than the currently used PJI diagnostic tests. In many diagnostic tests, combining several biomarkers into panels is critical for improving diagnostic efficiency, enhancing the diagnostic precision for specific diseases, and reducing cost. In this study, we prove that combining alpha-defensin and C-reactive protein (CRP) as biomarkers possesses the potential to provide accurate PJI diagnosis. To further verify the result, we developed a multi-target lateral flow immunoassay strip (msLFIA) with staking pad design to obtain on-site rapid response for clinical diagnosis of PJI. A total of 10 synovial fluid samples were tested using the msLFIA, and the results showed that the combined measurements of synovial fluid alpha-defensin and CRP levels were consistent with those obtained from a commercial enzyme-linked immunosorbent assay kit. In addition, we developed a multi-target lateral flow immunoassay strip (msLFIA) with staking pad design to obtain on-site rapid response for clinical diagnosis of PJI, which the multi-target design is used to increase specificity and the stacking pad design is to enhance detection sensitivity. As a result, the turnaround time of the highly sensitive test can be limited from several hours to 20 min. We expect that the developed msLFIA possesses the potential for routine monitoring of PJI as a convenient, low-cost, rapid and easy to use detection device for PJI.


2018 ◽  
Vol 34 (1) ◽  
pp. 51-56 ◽  
Author(s):  
Masanori ISHII ◽  
Pattarachaya PREECHAKASEDKIT ◽  
Kentaro YAMADA ◽  
Orawon CHAILAPAKUL ◽  
Koji SUZUKI ◽  
...  

2016 ◽  
Vol 54 (6) ◽  
pp. 1557-1565 ◽  
Author(s):  
Martin Heller ◽  
Nimmo Gicheru ◽  
Georgina Tjipura-Zaire ◽  
Cecilia Muriuki ◽  
Mingyan Yu ◽  
...  

Contagious bovine pleuropneumonia (CBPP) is a severe respiratory disease that is widespread in sub-Saharan Africa. It is caused byMycoplasma mycoidessubsp.mycoides, a bacterium belonging to theMycoplasma mycoidescluster. In the absence of an efficient CBPP vaccine, improved and easy-to-use diagnostic assays for recurrent testing combined with isolation and treatment of positive animals represent an option for CBPP control in Africa. Here we describe the comprehensive screening of 17 immunogenicMycoplasma mycoidessubsp.mycoidesproteins using well-characterized bovine sera for the development of a novel cocktail enzyme-linked immunosorbent assay (ELISA) for laboratory use. Two recombinantMycoplasmaimmunogens, MSC_0136 and MSC_0636, were used to set up a standardized cocktail ELISA protocol. According to the results from more than 100 serum samples tested, the sensitivity and specificity of the novel cocktail ELISA were 85.6% and 96.4%, respectively, with an overall diagnostic accuracy comparable to that of the Office International des Epizooties (OIE)-prescribed serological assays. In addition, we provide a proof of principle for a field-applicable, easy-to-use commercially produced prototype lateral-flow test for rapid (<30-min) diagnosis of CBPP.


2020 ◽  
Author(s):  
Giovanni Visci ◽  
Vittorio Lodi ◽  
Roberta Bonfiglioli ◽  
Tiziana Lazzarotto ◽  
Francesco S. Violante ◽  
...  

AbstractBackgroundLimited information is available on prevalence and determinants of serologic response to SARS-CoV-2 infection among healthcare workers (HCWs).MethodsWe analyzed the results of serologic testing with chemiluminescence immunoassay analyzer (CLIA), lateral flow immunoassay (LFIA) and enzyme-linked immunosorbent assay (ELISA) test among 544 HCWs with at least one positive RT-PCR test and 157 HCWs with Covid-19 related symptoms without a positive RT-PCR test from public hospitals in Bologna, Northern Italy. Tests were performed between March and August 2020. We fitted multivariate logistic regression models to identify determinants of positive serology.ResultsThe sensitivity of SARS-CoV-2 was 75.2% (LFIA) and 90.6% (CLIA). No differences in seropositivity were observed by sex, while older HCWs had higher positivity than other groups, and nurses had higher positivity compared to physicians, but not other HCWs. An estimated 73.4% of HCWs with Covid-19 symptoms without RT-PCR test were not infected with SARS-CoV-2.ConclusionsOur study provides the best available data on sensitivity of serologic tests and on determinants of serologic response among HCWs positive for SARS-CoV-2, and provide evidence on the low specificity of Covid-19 related symptoms to identify infected HCWs.SummaryThe sensitivity of SARS-CoV-2 lateral flow immunoassay serology in healthcare workers (HCWs) was 75.2%. Older HCWs and nurses had higher positivity than other groups. An estimated 73.4% of HCWs with Covid-19 symptoms without RT-PCR test were not infected with SARS-CoV-2.


Sign in / Sign up

Export Citation Format

Share Document