Microbore flow-rates and protein chromatography

1987 ◽  
Vol 385 ◽  
pp. 65-74 ◽  
Author(s):  
Timothy D. Schlabach ◽  
Kenneth J. Wilson
2015 ◽  
Vol 2 (1) ◽  
pp. 6-12
Author(s):  
Agus Sugiarta ◽  
Houtman P. Siregar ◽  
Dedy Loebis

Automation of process control in chemical plant is an inspiring application field of mechatronicengineering. In order to understand the complexity of the automation and its application requireknowledges of chemical engineering, mechatronic and other numerous interconnected studies.The background of this paper is an inherent problem of overheating due to lack of level controlsystem. The objective of this research is to control the dynamic process of desired level more tightlywhich is able to stabilize raw material supply into the chemical plant system.The chemical plant is operated within a wide range of feed compositions and flow rates whichmake the process control become difficult. This research uses modelling for efficiency reason andanalyzes the model by PID control algorithm along with its simulations by using Matlab.


2021 ◽  
Vol 42 (1) ◽  
pp. 30-35 ◽  
Author(s):  
Donald P. Tashkin ◽  
Arkady Koltun ◽  
Róisín Wallace

Background: A generic combination of fluticasone propionate and salmeterol xinafoate inhalation powder in a premetered, multidose, nonreusable inhaler was recently approved. Objective: To assess the performance of the generic device. Methods: Findings from three studies with regard to device usability, function, and robustness were reviewed. Results: In a study to assess device function in patients and healthy volunteers, the generic device was successfully used by patients with asthma and chronic obstructive pulmonary disease who were either dry powder inhaler users or dry powder inhaler‐naive, even though they were not trained beyond being provided the instructions for use. In a study to measure inhaled flow rates generated by patients and healthy volunteers, the generic device consistently simulated the delivery of a full dose of drug, even to patients with severe respiratory disease and reduced inspiratory flow rates. Although the generic device had a slightly higher airflow resistance, this study demonstrated that this difference did not result in any clinically meaningful differences in terms of drug delivery. Pressure drop, a key parameter that drives the fluidization and aerosolization of the powder dose, was found to be comparable between the devices. In an open-label study, the generic device met all U.S. Food and Drug Administration specifications for device robustness after 21.5 days of twice-daily dosing via oral inhalation among 111 participants with asthma or chronic obstructive pulmonary disease. All inhalers tested demonstrated conformity with a pharmacopeia with respect to key quality parameters (assay, delivered dose uniformity, aerodynamic size distribution). There was no evidence of chemical degradation of the active ingredients, nor of microbial or water ingress into the powder, as a result of inhaler use.


1984 ◽  
Vol 19 (1) ◽  
pp. 87-100
Author(s):  
D. Prasad ◽  
J.G. Henry ◽  
P. Elefsiniotis

Abstract Laboratory studies were conducted to demonstrate the effectiveness of diffused aeration for the removal of ammonia from the effluent of an anaerobic filter treating leachate. The effects of pH, temperature and air flow on the process were studied. The coefficient of desorption of ammonia, KD for the anaerobic filter effluent (TKN 75 mg/L with NH3-N 88%) was determined at pH values of 9, 10 and 11, temperatures of 10, 15, 20, 30 and 35°C, and air flow rates of 50, 120, and 190 cm3/sec/L. Results indicated that nitrogen removal from the effluent of anaerobic filters by ammonia desorption was feasible. Removals exceeding 90% were obtained with 8 hours aeration at pH of 10, a temperature of 20°C, and an air flow rate of 190 cm3/sec/L. Ammonia desorption coefficients, KD, determined at other temperatures and air flow rates can be used to predict ammonia removals under a wide range of operating conditions.


1986 ◽  
Vol 21 (1) ◽  
pp. 50-57 ◽  
Author(s):  
D. R. Cullimore ◽  
N. Mansuy

Abstract A small diameter water well drilled in 1977 in the Town of Bulyea, Saskatchewan generated such a rapid plugging (biofouling) that by 1979 the flow rate was reduced by 59%. Heavy growths of non-specific iron bacteria were found in the water and biofouling projected to be the principal cause of the flow loss. Tyndallization (repeated pasteurizations) treatment was applied using a hot water recycling system installed above the well head. Using a displacement passive gravity direct injection of hot water at 82°C from a water heater into the well, a sequential elevation of water column temperatures occurred until bio-film dispersion occurred (pasteurization) at 45°C+. A recovery to original flow specifications was repeatedly obtained at time intervals ranging from 6 to 403 days. Between treatments, a recurrence of biofouling was noted with flow reductions of 0.06 – 0.07 1/min/day frequently being noted. The rate of plugging appeared to be affected by the previous sequence of pasteurization treatments. Tyndallization was found to satisfactorily control iron bacterial biofouling and maintain flow rates.


1986 ◽  
Vol 18 (4-5) ◽  
pp. 53-61 ◽  
Author(s):  
P. B. Birch ◽  
G. G. Forbes ◽  
N. J. Schofield

Early results from monitoring runoff suggest that the programme to reduce application of superphosphate to farmlands in surrounding catchments has been successful in reducing input of phosphorus to the eutrophic Peel-Harvey estuary. In the estuary this phosphorus fertilizes algae which grow in abundance and accumulate and pollute once clean beaches. The success of the programme has been judged from application of an empirical statistical model, which was derived from 6 years of data from the Harvey Estuary catchment prior to a major change in fertilizer practices in 1984. The model relates concentration of phosphorus with rate of flow and time of year. High phosphorus concentrations were associated with high flow rates and with flows early in the high runoff season (May-July). The model predicted that the distribution of flows in 1984 should have resulted in a flow-weighted concentration of phosphorus near the long-term average; the observed concentration was 25% below the long-term average. This means that the amount of phosphorus discharged into the Harvey Estuary could have been about 2 5% less than expected from the volume of runoff which occurred. However several more years of data are required to confirm this trend.


1995 ◽  
Vol 32 (7) ◽  
pp. 199-206 ◽  
Author(s):  
Martin Oldenburg ◽  
Ivan Sekoulov

In this study the use of zeolites as ion-exchangers for equalization of ammonia peak loadings in aerated biological activated filters was investigated. For this use zeolites were mixed with a filter medium and the nitrifying filter was loaded with ammonia peaks for two hours at different flow rates. It could be demonstrated that during the phase of higher inflow concentrations the zeolite was collecting ammonia. When the influent concentration decreased ammonia was desorbed from the zeolite and could be nitrified by the bacteria growing on the filter medium. It was shown that additional zeolites can equalize variations of ammonia, especially in filter units which are working at a high nitrification rate and which are very sensitive to varying influent conditions. During the operation time of the filter no separation of the zeolite by higher hydraulic loading or by backwashing could be recognized. So the upgrading of nitrifying filters with zeolite represents an additional security for effluents containing oscillating ammonia concentrations.


Author(s):  
Alexander D. Bekman ◽  
Sergey V. Stepanov ◽  
Alexander A. Ruchkin ◽  
Dmitry V. Zelenin

The quantitative evaluation of producer and injector well interference based on well operation data (profiles of flow rates/injectivities and bottomhole/reservoir pressures) with the help of CRM (Capacitance-Resistive Models) is an optimization problem with large set of variables and constraints. The analytical solution cannot be found because of the complex form of the objective function for this problem. Attempts to find the solution with stochastic algorithms take unacceptable time and the result may be far from the optimal solution. Besides, the use of universal (commercial) optimizers hides the details of step by step solution from the user, for example&nbsp;— the ambiguity of the solution as the result of data inaccuracy.<br> The present article concerns two variants of CRM problem. The authors present a new algorithm of solving the problems with the help of “General Quadratic Programming Algorithm”. The main advantage of the new algorithm is the greater performance in comparison with the other known algorithms. Its other advantage is the possibility of an ambiguity analysis. This article studies the conditions which guarantee that the first variant of problem has a unique solution, which can be found with the presented algorithm. Another algorithm for finding the approximate solution for the second variant of the problem is also considered. The method of visualization of approximate solutions set is presented. The results of experiments comparing the new algorithm with some previously known are given.


Sign in / Sign up

Export Citation Format

Share Document