Trace element levels in whole blood samples from residents of the city Badajoz, Spain

1999 ◽  
Vol 229 (3) ◽  
pp. 209-215 ◽  
Author(s):  
M.A. Moreno ◽  
C. Marin ◽  
F. Vinagre ◽  
P. Ostapczuk
Author(s):  
Tatiana Komarova ◽  
Daniel McKeating ◽  
Anthony V. Perkins ◽  
Ujang Tinggi

The levels of trace elements in whole blood and plasma have been widely used for assessing nutritional status and monitoring exposure and can vary widely in populations from different geographical regions. In this study, whole blood samples (n = 120) and plasma samples (n = 120) were obtained from healthy donors attending the Red Cross Blood Bank (Queensland Red Cross Blood Service), which provided information for age and sex. There were 71 males (age range: 19–73 years) and 49 females (age range: 18–72 years) for whole blood samples, and 59 males (age range: 19–81 years) and 61 females (age range: 19–73 years) for plasma samples. The main aim of the study was to provide information on blood reference levels of 21 trace elements (Ag, Al, As, Bi, Br, Cd, Co, Cr, Cu, Hg, I, Mn, Mo, Ni, Pb, Sb, Se, Tl, U, V, Zn) in Queensland. The study also aimed to assess differences in trace element blood levels between males and females and the effect of age. The trace element levels in blood samples were analysed using inductively coupled plasma mass spectrometry (ICP-MS) and the standard reference materials of Seronorm (Trace Elements Whole Blood) and UTAK (Trace Elements Serum) were used for quality control and assurance. The study found wide variations of trace element levels in whole blood and plasma, and generally the levels were comparable to other countries. No detectable levels were found for Bi, Cr, U and V in whole blood, but V levels were found in plasma samples. There were significant differences between males and females for whole blood Cu (p < 0.001), I (p = 0.009), Tl (p = 0.016) and Zn (p = 0.016). Significant differences were also found for plasma Cu (p < 0.001) and Se (p = 0.003) between males and females. There were trends of increased levels of blood Pb, Se and Zn with age. The study has provided further information on a wide range of trace elements in blood as reference levels for Queensland and Australia which are currently lacking.


2010 ◽  
Vol 41 (02) ◽  
Author(s):  
N Shazi ◽  
A Böss ◽  
HJ Merkel ◽  
F Scharbert ◽  
D Hannak ◽  
...  

Separations ◽  
2021 ◽  
Vol 8 (6) ◽  
pp. 78
Author(s):  
Sevasti Karampela ◽  
Jessica Smith ◽  
Irene Panderi

An ever-increasing need exists within the forensic laboratories to develop analytical processes for the qualitative and quantitative determination of a broad spectrum of new psychoactive substances. Phenylethylamine derivatives are among the major classes of psychoactive substances available on the global market and include both amphetamine analogues and synthetic cathinones. In this work, an ultra-high-performance liquid chromatography-positive ion electrospray ionization tandem mass spectrometric method (UHPLC-ESI-MS/MS) has been developed and fully validated for the determination of 19 psychoactive substances, including nine amphetamine-type stimulants and 10 synthetic cathinone derivatives, in premortem and postmortem whole blood. The assay was based on the use of 1 mL premortem or postmortem whole blood, following solid phase extraction prior to the analysis. The separation was achieved on a Poroshell 120 EC-C18 analytical column with a gradient mobile phase of 0.1% formic acid in acetonitrile and 0.1% formic acid in water in 9 min. The dynamic multiple reaction monitoring used in this work allowed for limit of detection (LOD) and lower limit of quantitation (LOQ) values of 0.5 and 2 ng mL−1, respectively, for all analytes both in premortem and postmortem whole blood samples. A quadratic calibration model was used for the 12 quantitative analytes over the concentration range of 20–2000 ng mL−1, and the method was shown to be precise and accurate both in premortem and postmortem whole blood. The method was applied to the analysis of real cases and proved to be a valuable tool in forensic and clinical toxicology.


2021 ◽  
Vol 2 (1) ◽  
pp. 100311
Author(s):  
Daniella C. Terenzi ◽  
Ehab Bakbak ◽  
Justin Z. Trac ◽  
Mohammad Al-Omran ◽  
Adrian Quan ◽  
...  

Author(s):  
Polina A. Dyachenko Timoshina ◽  
Leonid E. Dolotov ◽  
Ekaterina N. Lazareva ◽  
Anastasiia A. Kozlova ◽  
Olga A. Inozemtseva ◽  
...  

1994 ◽  
Vol 42 (3) ◽  
pp. 231-241 ◽  
Author(s):  
C. Shenberg ◽  
S. Spiegel ◽  
S. Chaitchik ◽  
P. Jordan ◽  
M. Kitzis ◽  
...  

1978 ◽  
Vol 24 (12) ◽  
pp. 2135-2138 ◽  
Author(s):  
K W Jackson

Abstract Each of 65 laboratories analyzed 10 whole-blood samples for erythrocyte protoporphyrin by one or more of several analytical procedures. These procedures were of two types: (a) extraction of protoporphyrin from the erythrocytes into ethyl acetate/acetic acid, re-extraction into hydrochloric acid, and fluorometric measurement; or (b) direct reading in a portable fluorometer (hematofluorometer), with no pretreatment of the blood sample. Interlaboratory correlation was generally poor, especially between laboratories using extraction procedures. Hematofluorometric results intercorrelated better, but they had a low bias as compared to the extraction approach. Nationwide standardization of the test is required to assure satisfactory interlaboratory performance and to identify laboratories whose results are sufficiently accurate to be used for interpretations according to guidelines set forth by the Center for Disease Control for erythrocyte protoporphyrin testing.


Sign in / Sign up

Export Citation Format

Share Document