In situ Transmission Electron Microscope observations of mesotaxial silicide formation in the CoSi2/Si system

Author(s):  
R. Hull ◽  
A.E. White ◽  
K.T. Short ◽  
S.M. Yalisove ◽  
D. Loretto

A new technique for synthesis of buried epitaxial metal silicide layers in Si (“mesotaxy”) by high-dose implantation of Co and Ni into Si surfaces has been developed. Subsequent to implantation at energies in the few hundred keV range and doses in the 1017Cm−2 regime, thermal annealing at temperatures up to 1000°C results in the formation of well-defined and relatively high quality Si/metal disilicide/Si structures.The exact implantation and processing conditions are crucial in determining the structure and quality of the buried silicide layer. In this work, we describe transmission electron microscope experiments which illuminate the silicide formation process both by static studies of as-implanted and annealed structures, and dynamical in-situ experiments where as-implanted structures are annealed inside the microscope to mimic the ex-situ annealing conditions. The structure geometry in these materials turns out to be close to ideal for such in-situ experimentation: typical implantation conditions for formation of a contiguous silicide layer result in tlqe metal layers being of the order a few hundred to a thousand Å and buried about 600-1000 Å below the Si surface. In-situ annealing in the plan-view geometry inhibits surface diffusion across the interfaces, which would be expected in the cross-sectional geometry (5). The typical penetration depths attainable in Si with 200 keV electrons, say ~ 1 micron, allow a significant thickness, hsubthin of Si substrate below the metal layer, thickness hm, to be retained during the in-situ experiment such that hm ≪hsubthin. This is important, as it ensures that the film stress condition (which arises because of the difference in bulk lattice parameters between the Si and metal silicide layers) is reasonably representative of the stress conditions relevant for the case of annealing on the unthinned substrate.

2000 ◽  
Vol 650 ◽  
Author(s):  
A. Meldrum ◽  
K. Beaty ◽  
L. A. Boatner ◽  
C. W. White

ABSTRACTIrradiation-induced amorphization of Cd2Nb2O7 pyrochlore was investigated by means of in-situ temperature-dependent ion-irradiation experiments in a transmission electron microscope, combined with ex-situ ion-implantation (at ambient temperature) and RBS/channeling analysis. The in-situ experiments were performed using Ne or Xe ions with energies of 280 and 1200 keV, respectively. For the bulk implantation experiments, the incident ion energies were 70 keV (Ne+) and 320 keV (Xe2+). The critical amorphization temperature for Cd2Nb2O7 is ∼480 K (280 keV Ne+) or ∼620 K (1200 keV Xe2+). The dose for in-situ amorphization at room temperature is 0.22 dpa for Xe2+, but is 0.65 dpa for Ne+ irradiation. Both types of experiments suggest a cascade overlap mechanism of amorphization. The results were analyzed in light of available models for the crystalline-to-amorphous transformation and were compared to previous ionirradiation experiments on other pyrochlore compositions.


1992 ◽  
Vol 268 ◽  
Author(s):  
Mauro P. Otero ◽  
Charles W. Allen

ABSTRACTA special technique is described for in situ transmission electron microscope (TEM) experiments involving simultaneous ion irradiation, in which the resultant phenomena are observed as in a cross-section TEM specimen. That is, instead of ion-irradiating the film or foil specimen normal to the major surfaces and observing in plan view (i.e., in the same direction), the specimen is irradiated edge-on (i.e., parallel to the major surfaces) and is observed normal to the depth direction with respect to the irradiation. The results of amorphization of Si, irradiated in this orientation by 1 or 1.5 MeV Kr, are presented and briefly compared with the usual plan view observations. The limitations of the technique are discussed and several experiments which might profitably employ this technique are suggested.


2017 ◽  
Vol 7 (1) ◽  
Author(s):  
F. J. T. Goncalves ◽  
G. W. Paterson ◽  
D. McGrouther ◽  
T. Drysdale ◽  
Y. Togawa ◽  
...  

2018 ◽  
Vol 24 (6) ◽  
pp. 647-656 ◽  
Author(s):  
Yueying Wu ◽  
Chenze Liu ◽  
Thomas M. Moore ◽  
Gregory A. Magel ◽  
David A. Garfinkel ◽  
...  

AbstractA new optical delivery system has been developed for the (scanning) transmission electron microscope. Here we describe the in situ and “rapid ex situ” photothermal heating modality of the system, which delivers >200 mW of optical power from a fiber-coupled laser diode to a 3.7 μm radius spot on the sample. Selected thermal pathways can be accessed via judicious choices of the laser power, pulse width, number of pulses, and radial position. The long optical working distance mitigates any charging artifacts and tremendous thermal stability is observed in both pulsed and continuous wave conditions, notably, no drift correction is applied in any experiment. To demonstrate the optical delivery system’s capability, we explore the recrystallization, grain growth, phase separation, and solid state dewetting of a Ag0.5Ni0.5 film. Finally, we demonstrate that the structural and chemical aspects of the resulting dewetted films was assessed.


Author(s):  
M.A. O’Keefe ◽  
J. Taylor ◽  
D. Owen ◽  
B. Crowley ◽  
K.H. Westmacott ◽  
...  

Remote on-line electron microscopy is rapidly becoming more available as improvements continue to be developed in the software and hardware of interfaces and networks. Scanning electron microscopes have been driven remotely across both wide and local area networks. Initial implementations with transmission electron microscopes have targeted unique facilities like an advanced analytical electron microscope, a biological 3-D IVEM and a HVEM capable of in situ materials science applications. As implementations of on-line transmission electron microscopy become more widespread, it is essential that suitable standards be developed and followed. Two such standards have been proposed for a high-level protocol language for on-line access, and we have proposed a rational graphical user interface. The user interface we present here is based on experience gained with a full-function materials science application providing users of the National Center for Electron Microscopy with remote on-line access to a 1.5MeV Kratos EM-1500 in situ high-voltage transmission electron microscope via existing wide area networks. We have developed and implemented, and are continuing to refine, a set of tools, protocols, and interfaces to run the Kratos EM-1500 on-line for collaborative research. Computer tools for capturing and manipulating real-time video signals are integrated into a standardized user interface that may be used for remote access to any transmission electron microscope equipped with a suitable control computer.


Author(s):  
Hyoung H. Kang ◽  
Michael A. Gribelyuk ◽  
Oliver D. Patterson ◽  
Steven B. Herschbein ◽  
Corey Senowitz

Abstract Cross-sectional style transmission electron microscopy (TEM) sample preparation techniques by DualBeam (SEM/FIB) systems are widely used in both laboratory and manufacturing lines with either in-situ or ex-situ lift out methods. By contrast, however, the plan view TEM sample has only been prepared in the laboratory environment, and only after breaking the wafer. This paper introduces a novel methodology for in-line, plan view TEM sample preparation at the 300mm wafer level that does not require breaking the wafer. It also presents the benefit of the technique on electrically short defects. The methodology of thin lamella TEM sample preparation for plan view work in two different tool configurations is also presented. The detailed procedure of thin lamella sample preparation is also described. In-line, full wafer plan view (S)TEM provides a quick turn around solution for defect analysis in the manufacturing line.


Sign in / Sign up

Export Citation Format

Share Document