Low-voltage field-emission SEM of polymeric membranes for glucose biosensors

Author(s):  
Lorna K. Mayo ◽  
Kenneth C. Moore ◽  
Mark A. Arnold

An implantable artificial endocrine pancreas consisting of a glucose sensor and a closed-loop insulin delivery system could potentially replace the need for glucose self-monitoring and regulation among insulin dependent diabetics. Achieving such a break through largely depends on the development of an appropriate, biocompatible membrane for the sensor. Biocompatibility is crucial since changes in the glucose sensors membrane resulting from attack by orinter action with living tissues can interfere with sensor reliability and accuracy. If such interactions can be understood, however, compensations can be made for their effects. Current polymer technology offers several possible membranes that meet the unique chemical dynamics required of a glucose sensor. Two of the most promising polymer membranes are polytetrafluoroethylene (PTFE) and silicone (Si). Low-voltage scanning electron microscopy, which is an excellent technique for characterizing a variety of polymeric and non-conducting materials, 27 was applied to the examination of experimental sensor membranes.

2002 ◽  
Vol 16 (28n29) ◽  
pp. 4387-4394 ◽  
Author(s):  
JINGYUE LIU

Low-voltage scanning electron microscopy (LV-SEM) enables us to directly examine non-conducting materials with high spatial resolution. Although use of ultra-low-energy electrons can provide further advantages for characterizing delicate samples, lens aberrations rapidly deteriorates the image resolution. The combined use of a retarding field and the probe-forming lens system can improve the image resolution for electrons with very low energies. In commercially available FEG-SEMs, the retarding field can simply be constructed by applying a negative potential to the specimen. Interesting contrast variations have been observed in ultra-low-voltage SEM images. In this short communication, we discuss the application of LV-SEM to examining semiconductor devices and also the recent development of the ultra-low-voltage SEM technique.


Author(s):  
V. K. Berry

The morphological characterization of any polymer blend plays an important part in the development of a new blend system because the properties of blends are dictated by phase morphology which is dependent upon the chemistry and the processing conditions. Light microscopy, scanning electron microscopy and transmission electron microscopy are the most commonly used microscopical techniques for morphological characterization. Transmission electron microscopy techniques provide the best resolution (≈ 0.3 nm) but are limited in the size of sample area and require elaborate sample preparation procedures. Surface charging and beam damage problems have been some of the drawbacks of conventional scanning electron microscopy with non-conducting materials like polymers.The use of low accelerating voltage scanning electron microscopy (LVSEM) in the characterization of polymers and other non-conducting materials is beginning to be recognized.


Author(s):  
V. K. Berry

The application of low voltage scanning electron microscopy (LVSEM) to the characterization of polymers and non-conducting materials, other than semiconductors, has not been well explored yet. Some of the theoretical considerations and practical limitations which prevented the development of commercial instruments have mostly been addressed with the result that machines are now available which are optimized for low voltage (≥ 0.5 kV) operation. The advantages of working at low voltages are beginning to be recognized outside the semi-conductor industry. When we image uncoated polymer surfaces at low beam energies (0.5-1.5 kV), no beam damage or charging artifacts are experienced, because in this region the emitted electrons are equal to or more than the incident electrons and there is no deposition of charge underneath the surface due to the lower penetration of the incident electrons.


Author(s):  
Marek Malecki ◽  
J. Victor Small ◽  
James Pawley

The relative roles of adhesion and locomotion in malignancy have yet to be clearly established. In a tumor, subpopulations of cells may be recognized according to their capacity to invade neighbouring tissue,or to enter the blood stream and metastasize. The mechanisms of adhesion and locomotion are themselves tightly linked to the cytoskeletal apparatus and cell surface topology, including expression of integrin receptors. In our studies on melanomas with Fluorescent Microscopy (FM) and Cell Sorter(FACS), we noticed that cells in cultures derived from metastases had more numerous actin bundles, then cells from primary foci. Following this track, we attempted to develop technology allowing to compare ultrastructure of these cells using correlative Transmission Electron Microscopy(TEM) and Low Voltage Scanning Electron Microscopy(LVSEM).


Author(s):  
Marek Malecki ◽  
James Pawley ◽  
Hans Ris

The ultrastructure of cells suspended in physiological fluids or cell culture media can only be studied if the living processes are stopped while the cells remain in suspension. Attachment of living cells to carrier surfaces to facilitate further processing for electron microscopy produces a rapid reorganization of cell structure eradicating most traces of the structures present when the cells were in suspension. The structure of cells in suspension can be immobilized by either chemical fixation or, much faster, by rapid freezing (cryo-immobilization). The fixation speed is particularly important in studies of cell surface reorganization over time. High pressure freezing provides conditions where specimens up to 500μm thick can be frozen in milliseconds without ice crystal damage. This volume is sufficient for cells to remain in suspension until frozen. However, special procedures are needed to assure that the unattached cells are not lost during subsequent processing for LVSEM or HVEM using freeze-substitution or freeze drying. We recently developed such a procedure.


Author(s):  
E. Dupré ◽  
G. Schatten

Sperm of decapod crustaceans are formed by a round or cup-shaped body, a complex acrosome and one a few appendages emerging from the main body. Although this sperm does not have motility, it has some components of the cytoskeleton like microtubules, which are found inside the appendages. Actin filaments have been found in the spike of penaeidae sperms. The actual participation of the crustacean decapod sperm cytoskeleton during fertilization is not well understood. Actin is supposed to play an active role in drawing the penaeidae shrimp sperm closer to the egg after bending of the spike. The present study was aimed at the localization of actin filaments in sperm of the Robinson Crusoe island lobster, Jasus frontalis and in the crayfish Orconectes propincus, by fluorescent probes and low voltage scanning electron microscopy.


Author(s):  
S.J. Krause ◽  
W.W. Adams

Over the past decade low voltage scanning electron microscopy (LVSEM) of polymers has evolved from an interesting curiosity to a powerful analytical technique. This development has been driven by improved instrumentation and in particular, reliable field emission gun (FEG) SEMs. The usefulness of LVSEM has also grown because of an improved theoretical and experimental understanding of sample-beam interactions and by advances in sample preparation and operating techniques. This paper will review progress in polymer LVSEM and present recent results and developments in the field.In the early 1980s a new generation of SEMs produced beam currents that were sufficient to allow imaging at low voltages from 5keV to 0.5 keV. Thus, for the first time, it became possible to routinely image uncoated polymers at voltages below their negative charging threshold, the "second crossover", E2 (Fig. 1). LVSEM also improved contrast and reduced beam damage in sputter metal coated polymers. Unfortunately, resolution was limited to a few tenths of a micron due to the low brightness and chromatic aberration of thermal electron emission sources.


Author(s):  
Arthur V. Jones

In comparison with the developers of other forms of instrumentation, scanning electron microscope manufacturers are among the most conservative of people. New concepts usually must wait many years before being exploited commercially. The field emission gun, developed by Albert Crewe and his coworkers in 1968 is only now becoming widely available in commercial instruments, while the innovative lens designs of Mulvey are still waiting to be commercially exploited. The associated electronics is still in general based on operating procedures which have changed little since the original microscopes of Oatley and his co-workers.The current interest in low-voltage scanning electron microscopy will, if sub-nanometer resolution is to be obtained in a useable instrument, lead to fundamental changes in the design of the electron optics. Perhaps this is an opportune time to consider other fundamental changes in scanning electron microscopy instrumentation.


2020 ◽  
Vol 10 (1) ◽  
Author(s):  
W. Han ◽  
M. Zheng ◽  
A. Banerjee ◽  
Y. Z. Luo ◽  
L. Shen ◽  
...  

AbstractThis paper demonstrates how secondary electron energy spectroscopy (SEES) performed inside a scanning electron microscope (SEM) can be used to map sample atomic number and acquire bulk valence band density of states (DOS) information at low primary beam voltages. The technique uses an electron energy analyser attachment to detect small changes in the shape of the scattered secondary electron (SE) spectrum and extract out fine structure features from it. Close agreement between experimental and theoretical bulk valance band DOS distributions was obtained for six different test samples, where the normalised root mean square deviation ranged from 2.7 to 6.7%. High accuracy levels of this kind do not appear to have been reported before. The results presented in this paper point towards SEES becoming a quantitative material analysis companion tool for low voltage scanning electron microscopy (LVSEM) and providing new applications for Scanning Auger Microscopy (SAM) instruments.