Distributions of Indoor and Outdoor Air Pollutants in Rio de Janeiro, Brazil:  Implications to Indoor Air Quality in Bayside Offices

1998 ◽  
Vol 32 (22) ◽  
pp. 3485-3490 ◽  
Author(s):  
Leila S. R. Brickus ◽  
Jari N. Cardoso ◽  
Francisco R. de Aquino Neto
2018 ◽  
Vol 28 ◽  
pp. 01022 ◽  
Author(s):  
Anna Mainka ◽  
Elwira Zajusz-Zubek ◽  
Barbara Kozielska ◽  
Ewa Brągoszewska

Children’s exposure to air pollutants is an important public health challenge. Indoor air quality (IAQ) in nursery school is believed to be different from elementary school. Moreover, younger children are more vulnerable to air pollution than higher grade children because they spend more time indoors, and their immune systems and bodies are less mature. The purpose of this study was to evaluate the indoor air quality (IAQ) at naturally ventilated rural nursery schools located in Upper Silesia, Poland. We investigated the concentrations of volatile organic compounds (VOCs), particulate matter (PM), bacterial and fungal bioaerosols, as well as carbon dioxide (CO2) concentrations in younger and older children's classrooms during the winter and spring seasons. The concentration of the investigated pollutants in indoor environments was higher than those in outdoor air. The results indicate the problem of elevated concentrations of PM2.5 and PM10 inside the examined classrooms, as well as that of high levels of CO2 exceeding 1,000 ppm in relation to outdoor air. The characteristics of PM and CO2 levels were significantly different, both in terms of classroom occupation (younger or older children) and of season (winter or spring).


2021 ◽  
Vol 13 (15) ◽  
pp. 8302
Author(s):  
Jenjira Kaewrat ◽  
Rungruang Janta ◽  
Surasak Sichum ◽  
Thongchai Kanabkaew

Indoor air quality is associated with academic performance and harmful health effects on students and teachers who participate in the classroom. Outdoor sources always contribute to classroom air quality. This study aims to estimate the amounts of indoor and outdoor pollutants and the influence of outdoor sources on open-air classrooms in a school located in the city. A health risk assessment was applied to assess the non-carcinogenic risk to students and teachers from exposure to the pollutants in the classroom. The concentrations of indoor NO2 ranged between 46.40 and 77.83 µg/m3, which is about 0.8 times that of outdoor NO2. A strong correlation and a high indoor/outdoor (I/O) ratio (>0.5) without a source, indicated that indoor NO2 is significantly influenced by outdoor sources. The range of indoor PM2.5 concentrations was 1.66 to 31.52 µg/m3 which was influenced by meteorological conditions. The indoor PM2.5 concentrations were affected by both indoor and outdoor sources. Although the level of indoor air pollutants met the official standard, the young children were exposed to indoor air pollutants which were above the recommended limits to human health with regard to the hazard index (HI) of 1.12. Instant measures such as regularly cleaning the classrooms, zoning the students, and installation of solid and vegetation barriers are recommended to reduce the daily dose of pollutants affecting students in open-air classrooms.


2012 ◽  
Vol 178-181 ◽  
pp. 711-717
Author(s):  
Shi Bin Geng ◽  
Ming Xing Xiao

This article use several different physical models to describe coupling relationship between indoor and outdoor air contaminants ,analysis the principle of the air filter air purification, discuss all the filters’ roles in improving IAQ.


2021 ◽  
pp. 1420326X2110382
Author(s):  
Nuodi Fu ◽  
Moon Keun Kim ◽  
Bing Chen ◽  
Stephen Sharples

This study investigated the impact of outdoor air pollutants on indoor air quality in a high-rise building, considering factors related to the seasons and air infiltration. Further, the impact of atmospheric weather conditions on air infiltration has been analysed in a downtown area of Suzhou, China. The influence of the outdoor air pollution rate on indoor air quality in the office building was investigated based on on-site measurements and computer simulations. Results showed that the impact of outdoor air pollutants on indoor air quality was highest in winter, followed by spring, autumn and summer. Furthermore, multiple factors, which affect the indoor air quality in a high-rise building, have been further investigated in this study, including stack effect, wind effect, infiltration rate, outdoor air pollution rate, seasonal change and air filter efficiency. The significant influence of these factors on the indoor air quality level with floor height variations has been verified. Based on the analysis, a high-efficiency filter is recommended to maintain healthy indoor air quality. Meanwhile, a double-filter system is required if a building is exposed to heavily polluted outdoor air considering the most substantial impact of outdoor air pollutants on indoor air quality in winter. Moreover, a numerical model of steady-state indoor PM2.5 concentration was established to determine the suitable air filter efficiency and airtightness.


Indoor Air ◽  
2017 ◽  
Vol 27 (6) ◽  
pp. 1168-1176 ◽  
Author(s):  
S. Langer ◽  
O. Ramalho ◽  
E. Le Ponner ◽  
M. Derbez ◽  
S. Kirchner ◽  
...  

1990 ◽  
Vol 6 (5) ◽  
pp. 103-115 ◽  
Author(s):  
H. J. Van De Wiel ◽  
E. Lebret ◽  
W. K. Van Der Lingen ◽  
H. C. Eerens ◽  
L.H. Vaas ◽  
...  

Several national and international health organizations have derived concentration levels below which adverse effects on men are not expected or levels below which the excess risk for individuals is less than a specified value. For every priority pollutant indoor concentrations below this limit are considered “healthy.” The percentage of Dutch homes exceeding such a limit is taken as a measure of indoor air quality for that component. The present and future indoor air quality of the Dutch housing stock is described for fourteen air pollutants. The highest percentages are scored by radon, environmental tobacco smoke, nitrogen dioxide from unvented combustion, and the potential presence of housedust mite and mould allergen in damp houses. Although the trend for all priority pollutants is downward the most serious ones remain high in the coming decades if no additional measures will be instituted.


2009 ◽  
Vol 43 (40) ◽  
pp. 6352-6359 ◽  
Author(s):  
Takeshi Ohura ◽  
Takashi Amagai ◽  
Xueyou Shen ◽  
Shuang Li ◽  
Ping Zhang ◽  
...  

2019 ◽  
Vol 887 ◽  
pp. 500-507
Author(s):  
Matthias Schuss ◽  
Mahnameh Taheri ◽  
Ulrich Pont ◽  
Ardeshir Mahdavi

The present contribution, reports on the results of ongoing research efforts on performance assessment of a number of buildings designed by the Austrian architect, Konrad Frey. He is a pioneer of energy-efficient architecture, and his designs, those dating back to the 1970s, adapted the principles of modern solar houses. The current study focuses on the Kindergarten Hart, which was especially designed focusing on the availability of cross ventilation option in building. For the purpose of analyzing thermal comfort, indoor air quality, and the occupants’ adaptive actions with respect to natural ventilation, we conducted long-term monitoring under summer and winter conditions. The monitoring efforts covered indoor and outdoor environmental conditions, as well as the state of windows. Thereby, study of the monitored dataset provides a better understanding of the building performance. Moreover, it makes it possible to examine whether the architect’s expectations in terms of thermal comfort and indoor air quality levels are fulfilled or not. In addition, investigation of the occupants’ interactions with windows, together with indoor and outdoor environmental conditions, assists understanding of possible associations between the window opening/closing and environmental parameters, as well as potential optimization of the control-oriented actions.


Sign in / Sign up

Export Citation Format

Share Document