Research Affirms Real-World Effectiveness of High-Density Exposure Treatment for Agoraphobia.

2001 ◽  
Author(s):  
K. Halweg ◽  
W. Fiegenbaum ◽  
M. Frank ◽  
B. Schroeder ◽  
I. von Witzleben
EP Europace ◽  
2021 ◽  
Vol 23 (Supplement_3) ◽  
Author(s):  
L Fiedler ◽  
F Roithinger ◽  
I Roca ◽  
F Lorgat ◽  
A Roux ◽  
...  

Abstract Funding Acknowledgements Type of funding sources: Private company. Main funding source(s): Abbott Background 3D mapping systems are pivotal to identify low voltage areas and to define ablation strategies. In this context, high-density multipolar mapping catheters with varying electrode configurations are used for accurate myocardial substrate definition. High density mapping using a grid shaped catheter allows for use of simultaneous analysis of adjacent orthogonal bipolar signals that may assist in more accurate substrate characterization and ablation strategy decisions. Purpose This was a prospective, multicenter observational study to characterize the utility of electroanatomical mapping with a high density grid-style mapping catheter (HD Grid) in subjects undergoing catheter ablation for persistent atrial fibrillation (PersAF) or ventricular tachycardia (VT) in real-world clinical settings. Methods Mapping was performed with the HD Grid catheter to generate high-density maps of cardiac chambers in order to assess the potential influence of the simultaneous orthogonal bipole configuration on PersAF and VT ablation strategies. Differences in substrate identification between simultaneous orthogonal bipole configuration and standard along-the-spline electrode configuration, and potential effects on ablation strategies were investigated. Results During the study period (January 2019 through April 2020), 367 subjects underwent catheter ablation for PersAF (N = 333, average age 64.1yr, 75% male) or VT (N = 34, average age = 64.3yr, 85.3% male). In total, 494 maps were generated to treat patients undergoing PersAF ablation and 57 to treat patients undergoing VT ablation. Compared to standard along-the-spline configuration, mapping with the simultaneous orthogonal bipole configuration showed differences in 57.8% (178/308) of maps generated, with the greatest difference noticed in surface area of low voltage (62.9%) and location of low voltage (55.6%). In comparisons performed live during the procedure (n = 50), simultaneous orthogonal bipole configuration assisted in identification of ablation targets in 70.0% of cases, changing the ablation strategy compared to that identified with along-the-spline configuration in 34.3%. In comparisons performed retrospectively after the procedure (n = 258), the ablation strategy identified with simultaneous orthogonal bipole configuration differed from along-the-spline configuration in 21.7% of maps. Even compared to a higher-density electrode configuration using all-bipoles rather than along-the-spline bipoles, simultaneous orthogonal bipole configuration identified differences in 57.1% of maps. Conclusion The HD grid catheter combined with simultaneous orthogonal bipole configuration can define myocardial substrate more accurately compared to standard along-the-spline configuration. The difference in substrate identification has potential impact on ablation strategy. Further clinical trials are needed to elucidate the role of orthogonal bipole configuration mapping and improved ablation success rates.


Author(s):  
Ivica Ico Bukvic ◽  
Gregory Earle ◽  
Disha Sardana ◽  
Woohun Joo

The Spatial Audio Data Immersive Experience (SADIE) project aims to identify new foundational relationships pertaining to hu-man spatial aural perception, and to validate existing relation-ships. Our infrastructure consists of an intuitive interaction in-terface, an immersive exocentric sonification environment, and a layer-based amplitude-panning algorithm. Here we highlight the system’s unique capabilities and provide findings from an initial externally funded study that focuses on the assessment of human aural spatial perception capacity. When compared to the existing body of literature focusing on egocentric spatial perception, our data show that an immersive exocentric environment enhances spatial perception, and that the physical implementation using high density loudspeaker arrays enables significantly improved spatial perception accuracy relative to the egocentric and virtual binaural approaches. The preliminary observations suggest that human spatial aural perception capacity in real-world-like immersive exocentric environments that allow for head and body movement is significantly greater than in egocentric scenarios where head and body movement is restricted. Therefore, in the design of immersive auditory displays, the use of immersive exocentric environments is advised. Further, our data identify a significant gap between physical and virtual human spatial aural perception accuracy, which suggests that further development of virtual aural immersion may be necessary before such an approach may be seen as a viable alternative.


EP Europace ◽  
2019 ◽  
Vol 21 (4) ◽  
pp. 655-661 ◽  
Author(s):  
Gerhard Hindricks ◽  
Stanislav Weiner ◽  
Tom McElderry ◽  
Pierre Jaïs ◽  
William Maddox ◽  
...  

2018 ◽  
Vol 41 ◽  
Author(s):  
Michał Białek

AbstractIf we want psychological science to have a meaningful real-world impact, it has to be trusted by the public. Scientific progress is noisy; accordingly, replications sometimes fail even for true findings. We need to communicate the acceptability of uncertainty to the public and our peers, to prevent psychology from being perceived as having nothing to say about reality.


Author(s):  
S. McKernan ◽  
C. B. Carter ◽  
D. Bour ◽  
J. R. Shealy

The growth of ternary III-V semiconductors by organo-metallic vapor phase epitaxy (OMVPE) is widely practiced. It has been generally assumed that the resulting structure is the same as that of the corresponding binary semiconductors, but with the two different cation or anion species randomly distributed on their appropriate sublattice sites. Recently several different ternary semiconductors including AlxGa1-xAs, Gaxln-1-xAs and Gaxln1-xP1-6 have been observed in ordered states. A common feature of these ordered compounds is that they contain a relatively high density of defects. This is evident in electron diffraction patterns from these materials where streaks, which are typically parallel to the growth direction, are associated with the extra reflections arising from the ordering. However, where the (Ga,ln)P epilayer is reasonably well ordered the streaking is extremely faint, and the intensity of the ordered spot at 1/2(111) is much greater than that at 1/2(111). In these cases it is possible to image relatively clearly many of the defects found in the ordered structure.


Author(s):  
L. Mulestagno ◽  
J.C. Holzer ◽  
P. Fraundorf

Due to the wealth of information, both analytical and structural that can be obtained from it TEM always has been a favorite tool for the analysis of process-induced defects in semiconductor wafers. The only major disadvantage has always been, that the volume under study in the TEM is relatively small, making it difficult to locate low density defects, and sample preparation is a somewhat lengthy procedure. This problem has been somewhat alleviated by the availability of efficient low angle milling.Using a PIPS® variable angle ion -mill, manufactured by Gatan, we have been consistently obtaining planar specimens with a high quality thin area in excess of 5 × 104 μm2 in about half an hour (milling time), which has made it possible to locate defects at lower densities, or, for defects of relatively high density, obtain information which is statistically more significant (table 1).


Author(s):  
Evelyn R. Ackerman ◽  
Gary D. Burnett

Advancements in state of the art high density Head/Disk retrieval systems has increased the demand for sophisticated failure analysis methods. From 1968 to 1974 the emphasis was on the number of tracks per inch. (TPI) ranging from 100 to 400 as summarized in Table 1. This emphasis shifted with the increase in densities to include the number of bits per inch (BPI). A bit is formed by magnetizing the Fe203 particles of the media in one direction and allowing magnetic heads to recognize specific data patterns. From 1977 to 1986 the tracks per inch increased from 470 to 1400 corresponding to an increase from 6300 to 10,800 bits per inch respectively. Due to the reduction in the bit and track sizes, build and operating environments of systems have become critical factors in media reliability.Using the Ferrofluid pattern developing technique, the scanning electron microscope can be a valuable diagnostic tool in the examination of failure sites on disks.


2010 ◽  
Vol 20 (3) ◽  
pp. 100-105 ◽  
Author(s):  
Anne K. Bothe

This article presents some streamlined and intentionally oversimplified ideas about educating future communication disorders professionals to use some of the most basic principles of evidence-based practice. Working from a popular five-step approach, modifications are suggested that may make the ideas more accessible, and therefore more useful, for university faculty, other supervisors, and future professionals in speech-language pathology, audiology, and related fields.


Sign in / Sign up

Export Citation Format

Share Document