scholarly journals Direct Reduction of Graphene Oxide/Nanofibrillated Cellulose Composite Film and its Electrical Conductivity Research

2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Junjun Chen ◽  
Hailong Li ◽  
Lihui Zhang ◽  
Chao Du ◽  
Tao Fang ◽  
...  
2020 ◽  
Vol 34 (25) ◽  
pp. 2050265 ◽  
Author(s):  
Ke Wang ◽  
Zhimin Zhou ◽  
Yuehui Wang

In this paper, waterborne polyurethane (WPU) conductive films incorporated with reduced graphene oxide (RGO) as conductive fillers were prepared by solution blending and tape casting method. The electrical conductivity, thermal conductivity and microstructures of the composite films were systematically investigated. The experimental results demonstrate that the electrical conductivity and thermal conductivity of the RGO–WPU composite films first increased then decreased with the increase of the RGO content. The resistivity of composite film with 7% RGO reaches to the smallest that is about [Formula: see text], and the thermal conductivity of the composite film with 7% graphene was about 0.29 W.m.K[Formula: see text], which an increase of 70% compared with pure WPU. The electrical conductivity of the composite film decreased with the increase of the original concentration of WPU solution and thickness of the composite film. As film heater, the composite film displayed effective and rapid heating at low input voltages owing to the good conductivity. With an input voltage was in the range of 10–24 V, the film took less than 30s to reach a steady-state temperature, demonstrating the fast response of the composite film heater and suitable for applications in the field of the fast temperature switching with low input voltages as flexible electrothermal heater.


2020 ◽  
Vol 145 ◽  
pp. 663-667 ◽  
Author(s):  
Xiong-Fei Zhang ◽  
Lian Song ◽  
Zhongguo Wang ◽  
Yaquan Wang ◽  
Lin Wan ◽  
...  

Author(s):  
Jiajun Hu ◽  
Hongyan Xia ◽  
Xinguang Hou ◽  
Ting Yang ◽  
Kang Si ◽  
...  

BP powders with high thermal conductivity were synthesized by a facile molten salt method and used as thermal conductive fillers to prepare nanofibrillated cellulose composite film with higher thermal conductivity.


The Analyst ◽  
2019 ◽  
Vol 144 (6) ◽  
pp. 1960-1967 ◽  
Author(s):  
Chao Chen ◽  
Pengcheng Zhao ◽  
Meijun Ni ◽  
Chunyan Li ◽  
Yixi Xie ◽  
...  

A temperature-induced sensing film consisting of poly(N-vinylcaprolactam) (PVCL), graphene oxide (GO) and glucose oxidase (GOD) was fabricated and used to modify a glassy carbon electrode (GCE).


Molecules ◽  
2019 ◽  
Vol 24 (23) ◽  
pp. 4247 ◽  
Author(s):  
Rita Petrucci ◽  
Isabella Chiarotto ◽  
Leonardo Mattiello ◽  
Daniele Passeri ◽  
Marco Rossi ◽  
...  

Natural methylxanthines, caffeine, theophylline and theobromine, are widespread biologically active alkaloids in human nutrition, found mainly in beverages (coffee, tea, cocoa, energy drinks, etc.). Their detection is thus of extreme importance, and many studies are devoted to this topic. During the last decade, graphene oxide (GO) and reduced graphene oxide (RGO) gained popularity as constituents of sensors (chemical, electrochemical and biosensors) for methylxanthines. The main advantages of GO and RGO with respect to graphene are the easiness and cheapness of synthesis, the notable higher solubility in polar solvents (water, among others), and the higher reactivity towards these targets (mainly due to – interactions); one of the main disadvantages is the lower electrical conductivity, especially when using them in electrochemical sensors. Nonetheless, their use in sensors is becoming more and more common, with the obtainment of very good results in terms of selectivity and sensitivity (up to 5.4 × 10−10 mol L−1 and 1.8 × 10−9 mol L−1 for caffeine and theophylline, respectively). Moreover, the ability of GO to protect DNA and RNA from enzymatic digestion renders it one of the best candidates for biosensors based on these nucleic acids. This is an up-to-date review of the use of GO and RGO in sensors.


2021 ◽  
Vol 129 (23) ◽  
pp. 235105
Author(s):  
L. Jamilpanah ◽  
M. Alihosseini ◽  
S. Ghasemi ◽  
N. Hassani ◽  
F. Peymanirad ◽  
...  

RSC Advances ◽  
2021 ◽  
Vol 11 (45) ◽  
pp. 27801-27811
Author(s):  
M. Vandana ◽  
Y. S. Nagaraju ◽  
H. Ganesh ◽  
S. Veeresh ◽  
H. Vijeth ◽  
...  

Representation of the synthesis steps of SnO2QDs/GO/PPY ternary composites and SnO2QDs/GO/PPY//GO/charcoal asymmetric supercapacitor device.


2014 ◽  
Vol 2014 ◽  
pp. 1-10 ◽  
Author(s):  
Gen Liu ◽  
Wei Ma ◽  
Yan Luo ◽  
Deng-ming Sun ◽  
Shuang Shao

Poly(methylene blue) and electrochemically reduced graphene oxide composite film modified electrode (PMB-ERGO/GCE) was successfully fabricated by electropolymerization and was used for simultaneous determination of uric acid (UA) and xanthine (Xa). Based on the excellent electrocatalytic activity of PMB-ERGO/GCE, the electrochemical behaviors of UA and Xa were studied by cyclic voltammetry (CV) and square wave voltammetry (SWV). Two anodic sensitive peaks at 0.630 V (versus Ag/AgCl) for UA and 1.006 V (versus Ag/AgCl) for Xa were given by CV in pH 3.0 phosphate buffer. The calibration curves for UA and Xa were obtained in the range of 8.00 × 10−8~4.00 × 10−4 M and 1.00 × 10−7~4.00 × 10−4 M, respectively, by SWV. The detection limits for UA and Xa were3.00×10-8 M and5.00×10-8 M, respectively. Finally, the proposed method was applied to simultaneously determine UA and Xa in human urine with good selectivity and high sensitivity.


2021 ◽  
pp. 138551
Author(s):  
He-Dong Huang ◽  
Zeyu Guo ◽  
Peng-yan Yang ◽  
Peng Chen ◽  
Jie Wu

Sign in / Sign up

Export Citation Format

Share Document