Determination of trace uranium by a photo-catalytic resonance fluorescence method coupled with dual cloud point extraction

2016 ◽  
Vol 8 (30) ◽  
pp. 5984-5993 ◽  
Author(s):  
Guirong Li ◽  
Jiekang Li ◽  
Qian Han

(1) Extracting and purifying uranium in complex samples by dCPE with [UO22+–SA1]. (2) Detecting uranium super sensitively by a photocatalytic RF method with [UO22+–SA2]. (3) Coupling with separation, purification and analysis procedures exhibited a number of advantages, including high selectivity, high sensitivity and low cost.

2014 ◽  
Vol 6 (21) ◽  
pp. 8779-8784
Author(s):  
Jia-Ming Liu ◽  
Zhen-bo Liu ◽  
Qitong Huang ◽  
Xiaofeng Lin

We report a new catalytic biosensor for the detection of rhamnose (Rha) based on combining the high sensitivity of a fluorescence method with the high selectivity of a catalytic reaction.


2013 ◽  
Vol 830 ◽  
pp. 345-348
Author(s):  
Lin Gao ◽  
Sheng Jie Chen ◽  
Fang Chen ◽  
Wen Hong Zhou ◽  
Jun Long Yao

A simple, sensitive, green and low cost detection method based on the cloud point extraction (CPE) separation and spectrophotometry was proposed for the determination of lead. In pH=9.0 H3BO3 buffer solution, Pb(II) reacts with 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP) in the presence of Triton X-100 yielding a hydrophobic complex, which then is extracted into micro-volume surfactant-rich phase. The calibration graph was linear in the range of 20-400 µg/L (at 560 nm). Under the optimized conditions, the detection limits of 10.94 µg/L and the relative standard deviations(RSD) of 2.0% (n=5) for Lead(II) were found, respectively. The sensitivity and absorbance of this method are at least five times higher when compared with that of usual 5-Br-PADAP spectrophotometry without CPE, and the proposed method has been applied to the determination of Lead in environment water samples with satisfactory results.


2016 ◽  
Vol 8 (12) ◽  
pp. 2673-2683 ◽  
Author(s):  
Nail Altunay ◽  
Ramazan Gürkan

In the present study, a simple, low-cost and efficient method was developed for the extraction and preconcentration of Cd(ii) from cosmetic products by using cloud point extraction (CPE) prior to spectrophotometric detection.


1973 ◽  
Vol 19 (5) ◽  
pp. 1425-1427
Author(s):  
M. A. Bol'shov ◽  
I. D. Guseev ◽  
A. V. Zybin ◽  
V. G. Koloshnikov ◽  
I. A. Maiorov ◽  
...  

2021 ◽  
Author(s):  
Naeime Salandari-Jolge ◽  
Ali A. Ensafi ◽  
Behzad Rezaei

Dipyridamole is a prescribed medication used to treat cardiovascular diseases, angina pectoris, imaging tests for heart patients, and myocardial infarction. Therefore, high selectivity and sensitivity, low cost, and high-performance speed...


Sign in / Sign up

Export Citation Format

Share Document