Emergence through delicate balance between the steric factor and molecular orientation: a highly bright and photostable DNA marker for real-time monitoring of cell growth dynamics

2017 ◽  
Vol 53 (17) ◽  
pp. 2571-2574 ◽  
Author(s):  
Pankaj Gaur ◽  
Ajay Kumar ◽  
Reena Dalal ◽  
Shalmoli Bhattacharyya ◽  
Subrata Ghosh

A bright and biostable molecular fluorogenic material for real-time monitoring of in vitro cellular growth dynamics.

2020 ◽  
Vol 11 (2) ◽  
pp. 425-432 ◽  
Author(s):  
Shegufta Farazi ◽  
Fan Chen ◽  
Henry Foster ◽  
Raelene Boquiren ◽  
Shelli R. McAlpine ◽  
...  

A pH responsive pMAA nanogel that demonstrates high loading capacity and rapid intracellular delivery of hydrophilic peptides.


2021 ◽  
Vol 900 ◽  
pp. 115674
Author(s):  
Muthaiah Annalakshmi ◽  
Sakthivel Kumaravel ◽  
T.S.T. Balamurugan ◽  
Shen-Ming Chen ◽  
Ju-Liang He

2015 ◽  
Vol 51 (32) ◽  
pp. 6948-6951 ◽  
Author(s):  
Yanfeng Zhang ◽  
Qian Yin ◽  
Jonathan Yen ◽  
Joanne Li ◽  
Hanze Ying ◽  
...  

Anin vitroandin vivodrug-reporting system is developed for real-time monitoring of drug release via the analysis of the concurrently released near-infrared fluorescence dye.


2018 ◽  
Vol 19 (11) ◽  
pp. 3538 ◽  
Author(s):  
Brandon Lehrich ◽  
Yaxuan Liang ◽  
Pooya Khosravi ◽  
Howard Federoff ◽  
Massimo Fiandaca

It is known that culture media (CM) promotes cellular growth, adhesion, and protects explanted primary brain cells from in vitro stresses. The fetal bovine serum (FBS) supplement used in most CM, however, contains significant quantities of extracellular vesicles (EVs) that confound quantitative and qualitative analyses from the EVs produced by the cultured cells. We quantitatively tested the ability of common FBS EV-depletion protocols to remove exogenous EVs from FBS-supplemented CM and evaluated the influence such methods have on primary astrocyte culture growth and viability. We assessed two methodologies utilized for FBS EV removal prior to adding to CM: (1) an 18-h ultracentrifugation (UC); and (2) a commercial EV-depleted FBS (Exo-FBS™). Our analysis demonstrated that Exo-FBS™ CM provided the largest depletion (75%) of total FBS EVs, while still providing 6.92 × 109 ± 1.39 × 108 EVs/mL. In addition, both UC and Exo-FBS™ CM resulted in poor primary astrocyte cell growth and viability in culture. The two common FBS EV-depletion methods investigated, therefore, not only contaminate in vitro primary cell-derived EV analyses, but also provide a suboptimal environment for primary astrocyte cell growth and viability. It appears likely that future CM optimization, using a serum-free alternative, might be required to advance analyses of cell-specific EVs isolated in vitro.


2021 ◽  
Author(s):  
Biswajit Roy ◽  
Rakesh Mengji ◽  
Samrat Roy ◽  
Bipul Pal ◽  
Avijit Jana ◽  
...  

In recent times, organelle-targeted drug delivery systems gained tremendous attention due to the site specific delivery of active drug molecules resulting in enhanced bioefficacy. In this context, the phototriggered drug delivery system (DDS) for releasing an active molecule is superior as it provides spatial and temporal control over the release. So far, near infrared (NIR) light responsive organelle targeted DDS has not yet been developed. Hence, we introduced a two-photon NIR-light responsive lysosome targeted ʽAIE + ESIPTʼ active single component DDS based on naphthalene chromophore. The Two-photon absorption cross-section of our DDS is 142 GM at 850 nm. The DDS was converted into pure organic nanoparticles for biological applications. Our nano-DDS is capable of selective targeting, AIE-luminogenic imaging, and drug release within the lysosome. In vitro studies using cancerous cell lines showed that our single component photoresponsive nanocarrier exhibited enhanced cytotoxicity and real-time monitoring ability of the drug release.


Sensors ◽  
2019 ◽  
Vol 19 (12) ◽  
pp. 2810 ◽  
Author(s):  
Amir Javan-Khoshkholgh ◽  
Aydin Farajidavar

High-resolution (HR) mapping of the gastrointestinal (GI) bioelectrical activity is an emerging method to define the GI dysrhythmias such as gastroparesis and functional dyspepsia. Currently, there is no solution available to conduct HR mapping in long-term studies. We have developed an implantable 64-channel closed-loop near-field communication system for real-time monitoring of gastric electrical activity. The system is composed of an implantable unit (IU), a wearable unit (WU), and a stationary unit (SU) connected to a computer. Simultaneous data telemetry and power transfer between the IU and WU is carried out through a radio-frequency identification (RFID) link operating at 13.56 MHz. Data at the IU are encoded according to a self-clocking differential pulse position algorithm, and load shift keying modulated with only 6.25% duty cycle to be back scattered to the WU over the inductive path. The retrieved data at the WU are then either transmitted to the SU for real-time monitoring through an ISM-band RF transceiver or stored locally on a micro SD memory card. The measurement results demonstrated successful data communication at the rate of 125 kb/s when the distance between the IU and WU is less than 5 cm. The signals recorded in vitro at IU and received by SU were verified by a graphical user interface.


2008 ◽  
Vol 124 (4) ◽  
pp. 2485-2485
Author(s):  
Lucie Somaglino ◽  
Guillaume Bouchoux ◽  
Jean‐Louis Mestas ◽  
Adrien Matias ◽  
Jean‐Yves Chapelon ◽  
...  

2019 ◽  
Vol 4 (1) ◽  
pp. 1900204 ◽  
Author(s):  
Francesco Decataldo ◽  
Marianna Barbalinardo ◽  
Denis Gentili ◽  
Marta Tessarolo ◽  
Maria Calienni ◽  
...  

Micromachines ◽  
2020 ◽  
Vol 11 (12) ◽  
pp. 1118
Author(s):  
Yao Zhang ◽  
Ning Yang ◽  
Liangliang Xie ◽  
Fangyu Shu ◽  
Qian Shi ◽  
...  

In vitro models of the liver have a good simulation of the micro-liquid environment inside the human liver and the communication between cell tissues, which provides an important research tool for drug research and liver disease treatment. In this paper, we designed a 3D liver chip and real-time monitoring system based on microfluidic technology. The in vitro model of the liver on the chip was established by the three-dimensional microfluidic chip pipeline and the corresponding microwell array. Meanwhile, the culture medium is continuously injected on the chip, and the electrochemical impedance spectroscopy and near-infrared spectroscopy of the liver chip are recorded and analyzed from day one to day five. When the 3D cultured liver chip in vitro model reached a certain period and stabilized, paracetamol with varying gradients of concentration was applied to the cultured cells for drug resistance testing. The experimental results show that the liver chip and its monitoring system designed in this paper can maintain 100% cell viability of hepatocytes in vitro for a long time. Furthermore, it can meet the requirements of measurement technologies such as electrical impedance measurement and near-infrared spectroscopy in real-time, providing a stable culture platform for the further study of organ chips.


Sign in / Sign up

Export Citation Format

Share Document