scholarly journals Accurate experimental determination of gallium K- and L3-shell XRF fundamental parameters

2018 ◽  
Vol 33 (6) ◽  
pp. 1003-1013 ◽  
Author(s):  
Rainer Unterumsberger ◽  
Philipp Hönicke ◽  
Julien L. Colaux ◽  
Chris Jeynes ◽  
Malte Wansleben ◽  
...  

The fluorescence yield of the K- and L3-shell of gallium was determined using the radiometrically calibrated (reference-free) X-ray fluorescence instrumentation at the BESSY II synchrotron radiation facility.

2015 ◽  
Vol 93 (7) ◽  
pp. 760-764 ◽  
Author(s):  
Santosh Mirji ◽  
A.S. Bennal ◽  
Krishnananda ◽  
N.M. Badiger ◽  
M.K. Tiwari ◽  
...  

The K–L total vacancy transfer probabilities (ηKL) of some 3d elements have been determined using Indus-2 synchrotron radiation. The targets, such as Cr, Cu, and Zn, are excited by using 6.5, 10, and 11 keV synchrotron radiation, respectively. The K X-ray photons are detected with a silicon drift detector, which has an energy resolution of 130 eV at 5.9 keV. By measuring the K-shell fluorescence yield and K X-ray intensity ratio, the K–L vacancy transfer probabilities have been determined. Measured values have been compared with the theoretical values and other experimental values.


Metrologia ◽  
2017 ◽  
Vol 55 (1) ◽  
pp. 56-66 ◽  
Author(s):  
Y Ménesguen ◽  
M-C Lépy ◽  
P Hönicke ◽  
M Müller ◽  
R Unterumsberger ◽  
...  

2020 ◽  
Vol 86 (10) ◽  
pp. 5-9
Author(s):  
D. G. Filatova ◽  
A. A. Arkhipenko ◽  
M. A. Statkus ◽  
V. V. Es’kina ◽  
V. B. Baranovskaya ◽  
...  

An approach to sorptive separation of Se (IV) from solutions on a novel S,N-containing sorbent with subsequent determination of the analyte in the sorbent phase by micro-x-ray fluorescence method is presented. The sorbent copolymethylenesulfide-N-alkyl-methylenamine (CMA) was synthesized using «snake in the cage» procedure and proven to be stable in acid solutions. Conditions for quantitative extraction of Se (IV) were determined: sorption in 5 M HCl or 0.05 M HNO3 solutions when heated to 60°C, phase contact time being 1 h. The residual selenium content in the solution was determined by inductively coupled plasma mass spectrometry (ICP-MS) using 82Se isotope. The absence of selenium losses is proved and the mechanism of sorption interaction under specified conditions is proposed. The method of micro-x-ray fluorescence analysis (micro-RFA) with mapping revealed a uniform distribution of selenium on the sorbent surface. The possibility of determining selenium in the sorbent phase by micro-RFA is shown. When comparing the obtained results with the results of calculations by the method of fundamental parameters, it is shown the necessity of using standard samples of sorbates to obtain correct results of RFA determination of selenium in the sorbent phase.


1990 ◽  
Vol 68 (6) ◽  
pp. 2719-2722 ◽  
Author(s):  
A. Matsumuro ◽  
M. Kobayashi ◽  
T. Kikegawa ◽  
M. Senoo

2003 ◽  
Vol 125 (42) ◽  
pp. 12894-12906 ◽  
Author(s):  
Erik C. Wasinger ◽  
Frank M. F. de Groot ◽  
Britt Hedman ◽  
Keith O. Hodgson ◽  
Edward I. Solomon

2003 ◽  
Vol 321 (2-3) ◽  
pp. 221-232 ◽  
Author(s):  
A Yilmazbayhan ◽  
O Delaire ◽  
A.T Motta ◽  
R.C Birtcher ◽  
J.M Maser ◽  
...  