A simple method to construct a low-cost immunosensor based on a dithiol-functionalized polydopamine platform

2021 ◽  
Author(s):  
Bo Liu ◽  
Luanying Yang ◽  
Gang Wang ◽  
Sha He ◽  
Xiaobo Wang ◽  
...  

A simple and low-cost electrochemical CEA immunosensor was investigated via the self-polymerization of dopamine and a dithiol compound spacer for the covalent immobilization of antibodies. The designed CEA immunosensor exhibited a linear response and a low detection limit.

Author(s):  
J. J. Domanski ◽  
P. L. Haire ◽  
T.J. Sheets

AbstractAverage residue Ievels of DDT + TDE in flue-cured tobacco decreased from 6.1 ppm in 1970 to 0.85 ppm in 1972. DDT + TDE residues in Burley also dropped sharply from previous levels. In 1972 one sample from Kentucky contained 8.17 ppm; all other Burley samples were less than 0.25 ppm. DDT + TDE residues also declined in fire-cured and air-cured types; of these samples Tennessee dark air-cured tobacco contained the highest average residue (3.5 ppm of DDT + TDE). In 1972 over 90 % of the flue-cured samples were positive for toxaphene. Since each of our samples was a composite of tobacco from 10 farmers, we cannot conclude from this result that 90 % of the individual piles contained toxaphene. Significant amounts of toxaphene were found in other types also; for example, 50 % of the 1972 Burley samples had toxaphene concentrations greater than 0.5 ppm. Average endosulfan levels decreased between 1970 and 1972 in flue-cured and Burley tobaccos. However, in all of the dark air and dark fire-cured samples from Tennessee endosulfan residues exceeded 5 ppm. Average endrin residues were at or near the low detection limit in alI samples except fire-cured and dark air-cured tobacco from Tennessee; these averaged 0.26 and 0.17 ppm, respectively.


Materials ◽  
2020 ◽  
Vol 14 (1) ◽  
pp. 37
Author(s):  
Mayra K. S. Monteiro ◽  
Djalma R. Da Silva ◽  
Marco A. Quiroz ◽  
Vítor J. P. Vilar ◽  
Carlos A. Martínez-Huitle ◽  
...  

This study aims to investigate the applicability of a hybrid electrochemical sensor composed of cork and graphite (Gr) for detecting caffeine in aqueous solutions. Raw cork (RAC) and regranulated cork (RGC, obtained by thermal treatment of RAC with steam at 380 °C) were tested as modifiers. The results clearly showed that the cork-graphite sensors, GrRAC and GrRGC, exhibited a linear response over a wide range of caffeine concentration (5–1000 µM), with R2 of 0.99 and 0.98, respectively. The limits of detection (LOD), estimated at 2.9 and 6.1 µM for GrRAC and GrRGC, suggest greater sensitivity and reproducibility than the unmodified conventional graphite sensor. The low-cost cork-graphite sensors were successfully applied in the determination of caffeine in soft drinks and pharmaceutical formulations, presenting well-defined current signals when analyzing real samples. When comparing electrochemical determinations and high performance liquid chromatography measurements, no significant differences were observed (mean accuracy 3.0%), highlighting the potential use of these sensors to determine caffeine in different samples.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Ananthamurthy Koteshwara ◽  
Nancy V. Philip ◽  
Jesil Mathew Aranjani ◽  
Raghu Chandrashekhar Hariharapura ◽  
Subrahmanyam Volety Mallikarjuna

AbstractA carefully designed ammonium sulfate precipitation will simplify extraction of proteins and is considered to be a gold standard among various precipitation methods. Therefore, optimization of ammonium sulfate precipitation can be an important functional step in protein purification. The presence of high amounts of ammonium sulphate precludes direct detection of many enzymatically active proteins including reducing sugar assays (e.g. Nelson-Somogyi, Reissig and 3,5-dinitrosalicylic acid methods) for assessing carbohydrases (e.g. laminarinase (β (1–3)-glucanohydrolase), cellulases and chitinases). In this study, a simple method was developed using laminarin infused agarose plate for the direct analysis of the ammonium sulphate precipitates from Streptomyces rimosus AFM-1. The developed method is simple and convenient that can give accurate results even in presence of ammonium sulfate in the crude precipitates. Laminarin is a translucent substrate requiring the use of a stain to visualize the zones of hydrolysis in a plate assay. A very low-cost and locally available fluorescent optical fabric brightener Tinopal CBS-X has been used as a stain to detect the zones of hydrolysis. We also report simple methods to prepare colloidal chitin and cell free supernatant in this manuscript.


Author(s):  
Ziyu Wang ◽  
Meiyun Xu ◽  
Nan Zhang ◽  
Jian-Bin Pan ◽  
Xinqi Wu ◽  
...  

A mechanism of co-reactive group poisoning (CGP) was discovered for designing efficient I2 vapor sensors for early warning of a nuclear emergency, which give an ultra-low detection limit of 0.13 ppt as well as high selectivity.


2021 ◽  
Vol 8 (3) ◽  
pp. 205316802110317
Author(s):  
Rebecca A. Glazier ◽  
Amber E. Boydstun ◽  
Jessica T. Feezell

Open-ended survey questions can provide researchers with nuanced and rich data, but content analysis is subject to misinterpretation and can introduce bias into subsequent analysis. We present a simple method to improve the semantic validity of a codebook and test for bias: a “self-coding” method where respondents first provide open-ended responses and then self-code those responses into categories. We demonstrated this method by comparing respondents’ self-coding to researcher-based coding using an established codebook. Our analysis showed significant disagreement between the codebook’s assigned categorizations of responses and respondents’ self-codes. Moreover, this technique uncovered instances where researcher-based coding disproportionately misrepresented the views of certain demographic groups. We propose using the self-coding method to iteratively improve codebooks, identify bad-faith respondents, and, perhaps, to replace researcher-based content analysis.


2016 ◽  
Vol 18 (34) ◽  
pp. 23795-23802 ◽  
Author(s):  
Xiaolong Wang ◽  
Lu Zhou ◽  
Wei Lai ◽  
Tao Jiang ◽  
Jun Zhou

We present a recyclable SERS-based immunoassay for CA19-9 with a low detection limit of 5 U mL−1. The linking between TiO2-NTs and 4MBA was destroyed by catalyzing 4MBA into 4-sulfobenzoate upon UV irradiation, which was clarified by UPLC/ESI-tqMS and density functional theory.


RSC Advances ◽  
2016 ◽  
Vol 6 (3) ◽  
pp. 1722-1728 ◽  
Author(s):  
Pankaj Gupta ◽  
Munetaka Oyama ◽  
Rajendra N. Goyal

Electrochemical oxidation of 8-hydroxydeoxyguanosine (8-OHdG) and its detection with low detection limit is reported at pyrolytic graphite electrode.


The Analyst ◽  
2015 ◽  
Vol 140 (10) ◽  
pp. 3557-3564 ◽  
Author(s):  
Yaoguang Wang ◽  
Yueyun Li ◽  
Hongmin Ma ◽  
Aiping Guo ◽  
Bin Du ◽  
...  

An ultrasensitive electrochemical immunosensor was developed for detecting CD146. rGO-TEPA enhanced the loading capacity of Ab1 and facilitated the electron transfer. Au and Pd nanoparticles on the TiO2 colloidal sphere facilitated the decomposition of H2O2. The immunosensor exhibited an extremely low detection limit of 1.6 pg mL−1 for CD146.


2021 ◽  
pp. 130847
Author(s):  
Na wang ◽  
Rongrong Jin ◽  
Yue Zhou ◽  
Liupeng Zhao ◽  
Tianshuang Wang ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document