scholarly journals Influence of the amount of inflowing wastewater on concentrations of pollutions contained in the wastewater in the Nowy Targ sewerage system

2019 ◽  
Vol 86 ◽  
pp. 00024 ◽  
Author(s):  
Elwira Nowobilska-Majewska ◽  
Piotr Bugajski

This study presents the results of the analysis concerning the influence of the amount of inflowing wastewater on concentrations of organic and biogenic pollutants, as well as chromium ions in wastewater flowing into the collective sewage treatment plant in Nowy Targ. The research was carried out in 2016 and 2017, where in the period of 24 months a total number of 87 wastewater samples were collected in order to determine the concentration of the analyzed pollution indicators. During this period, the average daily inflow of wastewater to the sewage treatment plant was also analyzed. Based on the analysis of linear correlation, it was stated that there is a high dependence of concentrations of organic and biogenic pollutants on the amount of inflowing raw wastewater. Furthermore, it was found that there is an average dependence of chromium ion concentrations in raw wastewater on the amount of inflowing wastewater. In order to minimize the high variability of the concentration of pollutants in raw wastewater, it is recommended to reconstruct the sewerage system from the combined sewer system to the distribution system. Additionally, it is recommended to monitor the sewerage network in order to eliminate illegal inflows of rainwater and industrial wastewater from furrier’s production facility.

1993 ◽  
Vol 27 (12) ◽  
pp. 183-186
Author(s):  
O. B. Hansen ◽  
C. Jacobsen ◽  
P. Skat Nielsen

Copenhagen's plans to cut pollution loads from combined sewer overflows involves increased storage capacity in the sewer system, real time control of that system, and increased hydraulic loading for the treatment plant. Modelling studies have been used to examine the consequences.


2011 ◽  
Vol 63 (10) ◽  
pp. 2123-2130 ◽  
Author(s):  
A. Rodríguez ◽  
R. Rosal ◽  
M. J. Gomez ◽  
E. García-Calvo ◽  
A. R. Fernandez-Alba

The system ozone and hydrogen peroxide was used to reclaim wastewater from the secondary clarifier from a Sewage Treatment Plant (STP) of Alcalá de Henares (Madrid-Spain). The assays were performed by bubbling a gas mixture of oxygen and ozone, with ∼24 g Nm−3 of ozone concentration, through a volume of wastewater samples for 20 minutes at 25°C . The removal of dissolved micropollutants such as Pharmaceutical and Personal Care Products (PPCPs) and Organic Carbon (TOC) was enhanced by adding periodic pulses of hydrogen peroxide while keeping pH above 8.0 throughout the runs. Removal efficiency ratios in the range of 7–26 mg O3/mg TOC and 0.24 mg O3 /ng micropollutants at 5 minutes of ozonation were assessed as reference data to reclaim wastewater from STP. The relation between the extent of TOC removed and ozone doses used was related by a second-order kinetic model in which the time-integrated ozone-hydrogen peroxide concentration was included.


2001 ◽  
Vol 36 (4) ◽  
pp. 781-792 ◽  
Author(s):  
Chris Marvin ◽  
John Coakley ◽  
Tatiana Mayer ◽  
Mitra Brown ◽  
Lina Thiessen

Abstract An analytical method to determine faecal sterols was developed and applied to the analysis of samples including pig manure, sewage treatment plant sludge and combined sewer overflow effluent. Compounds including coprostanol (5β-cholestan-3β-ol), epicoprostanol (5β-cholestan-3α-ol), cholesterol (cholestan-5-en-3β-ol) and dihydrocholesterol (cholestanol, 5α-cholestan-3β-ol) were quantified in these source samples and their relative ratios calculated to investigate their potential application as source tracers. A mean coprostanol:epicoprostanol ratio of 7.6 ± 1.17 was calculated for pig manure samples from three Ontario livestock operations. This ratio was much lower (approximately 1.8) for sewage treatment plant sludge while the ratio for a combined sewer overflow effluent was very high (approximately 70). This approach, with the addition of physical measurements (e.g., current velocities) and meteorological data, may assist in determination of the influence of shore-based activities, including sewage treatment and livestock operations, on aquatic systems.


2017 ◽  
Vol 24 (1) ◽  
pp. 195-206 ◽  
Author(s):  
Sylwia Myszograj ◽  
Ewelina Płuciennik-Koropczuk ◽  
Anita Jakubaszek

Abstract The paper presents the results of studies concerning the designation of COD fraction in raw wastewater. The research was conducted in four municipal mechanical-biological sewage treatment plants and one industrial sewage treatment plant. The following fractions of COD were determined: non-biodegradable (inert) soluble SI, biodegradable soluble fraction SS, particulate slowly degradable XS and particulate non-biodegradable XI. The methodology for determining the COD fraction was based on the ATV-A131 guidelines and Łomotowski-Szpindor methodology. The real concentration of fractions in raw wastewater and the percentage of each fraction in total COD are different from data reported in the literature.


1998 ◽  
Vol 33 (3) ◽  
pp. 389-402-402 ◽  
Author(s):  
Hing-Biu Lee ◽  
Thomas E. Peart

Abstract A survey of the concentrations of nonylphenol ethoxylates (NPnEO) and their metabolites in wastewater samples collected from a Canadian sewage treatment plant using primary and secondary treatment is presented. Twenty-four-hour composite raw sewage, primary effluent and final effluent samples were collected monthly over a one-year period. Levels of NPnEO (n = 1 to 17) and their metabolites, nonylphenol (NP) and nonylphenoxy carboxylic acids (NPnEC), in these samples were determined by HPLC and GC/MS methods. While ca. 85% of the total alkylphenolics in raw sewage are ethoxylates, the major component (nearly 80%) in the final effluent was in the form of carboxylic acids. During this study period, the median total alkylphenolic concentrations in raw sewage and final effluent were 526 and 248 nmol/L, respectively, representing an overall elimination rate of 53%. The estimated daily discharge of the nonylpheno-lics to the aquatic environment varied from 15 to 44 moles, with a median value of 20 moles. These data suggested that conventional sewage treatments are ineffective in the removal of the surfactant-derived metabolites.


1992 ◽  
Vol 25 (4-5) ◽  
pp. 51-58
Author(s):  
B. Teichgräber

The Emschergenossenschaft plans to improve the Emscher drainage system by separating sewage and clean water. 6 or 7 subcatchment areas will be created and served by separate wastewater treatment plants. The Bottrop WWTP has been planned for 1.3 million population equivalents. It is scheduled to start operation in 1995 and its costs are estimated as totalling 820 million DM in total. Biological treatment will be effected by a low-loaded, single-stage activated sludge system with cascade denitrification and modified UCT process.


1996 ◽  
Vol 33 (10-11) ◽  
pp. 71-78 ◽  
Author(s):  
Ian B. Law

There has been increasing interest in reuse of effluent from sewage treatment plants in Australia in recent years, not only for agricultural or land irrigation purposes but also for the provision of dual water supplies to residential areas for the non-potable purposes of toilet flushing, car washing, garden watering and park or other open space irrigation. The Rouse Hill development in the north west of Sydney is Australia's first full scale application of domestic non-potable reuse, with the sewage treatment plant and the dual water distribution system being commissioned in late 1994. This paper describes the Rouse Hill project as a whole including the reasoning behind the installation of the dual water supply system, the design of the sewage treatment plant, the effluent qualities achieved, the design of the dual water distribution system and the requirements of the regulatory authority, the NSW Environmental Protection Authority.


1998 ◽  
Vol 37 (1) ◽  
pp. 333-340 ◽  
Author(s):  
Joachim Guderian ◽  
Andreas Durchschlag ◽  
Jürgen Bever

Based upon the connection of a simulation program for combined sewer systems with the IAWQ-Activated Sludge Model No.1 the new simulation tool GEMINI was developed, which allows the calculation of sewer and sewage treatment plant as a unit. Some obtained results are presented in an example. They suggest, that for every treatment plant a rate of inflow is determinable, which leads to a minimum of total emissions out of sewer and treatment plant. The optimal value of sewage treatment plant inflow in the example is distinctly greater than the design flow rate fixed in German design rules. So it is recognizable that a rigid flow management for sewer and treatment plant does not always fulfil the aim of minimization of total emissions.


2020 ◽  
Vol 699 ◽  
pp. 134426 ◽  
Author(s):  
Andrea F. Brunsch ◽  
Pedro Zubieta Florez ◽  
Alette A.M. Langenhoff ◽  
Thomas L. ter Laak ◽  
Huub H.M. Rijnaarts

1985 ◽  
Vol 17 (6-7) ◽  
pp. 1223-1231
Author(s):  
A. S. Hogendoorn-Roozemond

Quantitative information was obtained on the processes of sedimentation, mineralization and resuspension of organic matter in a combined sewerage system by means of statistical analysis of dry and wet weather data on sewage flows. The effects of temperature and length of intermittent dry weather periods on daily pollutant loads were also evaluated. For the sewerage system investigated it was found that in summer 5-26% of the BOD produced is mineralized in the system before reaching the sewage treatment plant. Due to sedimentation under dry weather conditions up to 12% of the daily organic load produced may be present in the sewers as resuspendable deposits; in winter this percentage may even amount to 20-30% because of slow mineralization.