The construction of a new countryside requires a compr hensive improvement in the building standards of villages and towns, and the seismic resistance of buildings in earthquake-prone areas has attracted much attention. Due to the backward economic development of villages and towns, the development of seismic isolation structure and energy dissipation structure is hindered. To build houses with better seismic performance, the economic efficiency of seismic isolation and energy dissipation structures has become a matter of close concern to the local people and the government. This article compares the economic differences between the original seismic structure, the base isolation structure, and the seismic damping structure from the costs incurred during the entire life cycle of the building, and provides economic reference for the new rural seismic isolation building.

Author(s):  
R. L. Mayes ◽  
A. G. Brown ◽  
D. Pietra

Seismic isolation with energy dissipation is a technology that has been used in New Zealand since 1978 for bridges and buildings. During this period it has seen limited use, tending to be applied mainly to historically significant buildings, or buildings that have special functional requirements. Seismic isolation has the ability to significantly improve the seismic performance of existing buildings through a seismic retrofit, or to create new earthquake-resilient buildings. Both of these applications are of greater relevance throughout New Zealand following the Canterbury earthquakes. Consequently, the consideration of seismic isolation is no longer limited to those buildings at the top end of the Importance Level spectrum. This paper examines the broad technical issues associated with isolation and energy dissipation. It discusses the benefits and costs of seismic isolation, and presents guidelines for cost estimation at the feasibility stage of projects. We will explore the cost-benefits for building owners, and discuss whether base isolation can replace earthquake insurance for the building and its contents, and business interruption insurance.


2014 ◽  
Vol 1010-1012 ◽  
pp. 250-253
Author(s):  
Ji Yang Li ◽  
Wen Fang Zhang

Seismic can be divided into passive seismic and active seismic. Seismic isolation technology belong to the second type. Base isolation structure is defined by setting the isolation layer between the superstructure and foundation building, to extend the natural period architecture, increasing the damping to reduce structural seismic response. It is a passive control system. Compared with the traditional seismic structure, it mainly through the isolation layer to absorb and dissipate energy, reducing the response to the earthquake.


Author(s):  
Takahiro Shimada ◽  
Tatsuya Fujiwaka ◽  
Satoshi Moro

In Japan, a number of three-dimensional base isolation systems have been studied for application to new nuclear plant concepts such as the FBR, but these efforts have not so far yielded practically applicable results. The impeding factor has been the difficulty of obtaining an adequate capacity on the vertical isolator for supporting the mass of an actual structure and for suppressing rocking motion. In this paper, we propose a new three-dimensional isolation system that should solve the foregoing problem. The system is constituted of a set of hydraulic load-carrying cylinders connected to accumulator units containing compressed gas, a set of rocking-suppression cylinders connected in series, and a laminated rubber bearing laid under each load-carrying cylinder. The present paper covers a basic examination for applying the proposed system to a FBR plant now under development in Japan. In order to verify expected system performance, the load-carrying cylinders were first tested independently of rocking-suppression cylinders, and this was followed by integrated dynamic test of the system incorporating both load-carrying and rocking suppression cylinders. Response analysis reflecting the test results has indicated the proposed system to be well applicable to the envisaged commercialized FBR. The study was undertaken as part of a research and development project sponsored by the government for realizing a three-dimensional seismic isolation system applicable to future FBR.


2009 ◽  
Vol 4 (3) ◽  
pp. 229-238 ◽  
Author(s):  
Yasuhiro Tsuneki ◽  
◽  
Shingo Torii ◽  
Katsuhide Murakami ◽  
Toshiyuki Sueoka ◽  
...  

For buildings of normal earthquake-resistant construction, it is essential to provide their structural frame with sufficient rigidity and strength horizontally and vertically, ensuring a uniform distribution of rigidity and strength in the plane. To this end, it is typical that those buildings adopt the same type of construction and structural system. On the other hand, in buildings of general base-isolation construction, their upper structure, which is supported by a base isolation layer, undergoes lessened seismic forces and therefore is able to tolerate concentration of rigidity and strength. This makes them available for construction with any types of structural systems, which in turn allows new structural planning realizing a greater freedom in architectural design; the same type of construction and structural system for the upper structure is generally adopted. In contrast, when a high-rise building is provided with an isolation layer in an intermediate level, its upper structure, which is placed above the isolation layer, has high seismic resistance as a seismic isolation structure. And a mass damper effect contributes to decrease in seismic responses in the lower structure, ensuring high seismic resistance of a building. This paper describes the physical properties of a seismic isolation layer system which is built at an middle-story of a building. It also introduce buildings by which potentials for new architectural planning are proposed through the use of this system.


Author(s):  
Akihiro Kashiwazaki ◽  
Takahiro Shimada ◽  
Tatsuya Fujiwaka ◽  
Katsuhiko Umeki

In Japan, a number of three-dimensional base isolation systems have been studied for application to new nuclear plant concepts such as the FBR, but these efforts have not so far yielded practically applicable results. The impeding factor has been the difficulty of obtaining an adequate capacity on the vertical isolator for supporting the mass of an actual structure and for suppressing rocking motion. In this paper, we propose a new three-dimensional base isolation system that should solve the foregoing problem. The system is constituted of a set of hydraulic load-carrying cylinders connected to accumulator units containing a compressed gas, another set of rocking-suppression cylinders connected in series, and a laminated rubber bearing laid under each load-carrying cylinder. The present paper covers a basic examination for applying the proposed system to a commercialized FBR now under development in Japan, together with static and dynamic loading tests performed on a scale model to verify expected system performance. Response analysis reflecting the test results has indicated the proposed system to be well applicable to the envisaged commercialized FBR. The study was undertaken as part of an R&D project sponsored by the government for realizing a three-dimensional seismic isolation system applicable to future FBR’s.


Open Physics ◽  
2020 ◽  
Vol 18 (1) ◽  
pp. 631-641
Author(s):  
Shujuan Yang

AbstractIn view of the problem of large earthquake displacement in the use of the original concrete engineering shear wall reinforcement method, the energy dissipation and damping structure is used to design the energy dissipation and damping structure reinforcement method in the concrete engineering shear wall. According to the design process of the set method, the anti-vibration coefficient of the concrete shear wall is tested. The energy dissipation structure is used to construct a shear damping wall, and the damper is added to the original shear wall. The concrete shear wall is strengthened by sticking steel technology. So far, the design of shear wall reinforcement method based on the energy dissipation structure has been completed. Compared with the original method, the displacement distance of this method is lower than that of the original method. In conclusion, the effect of shear wall reinforcement method based on the energy dissipation structure is better than that of the original method.


2021 ◽  
Author(s):  
◽  
Ivan Banović

The problem under consideration is the earthquake impact on structures. The subject of the performed research is the efficiency of seismic base isolation using layers of predominantly natural materials below the foundation, as well as the development of a numerical model for seismic analysis of structures with such isolation. The aseismic layers below foundation are made of limestone sand - ASL-1, stone pebbles - ASL-2, and stone pebbles combined with layers of geogrid and geomembrane - ASL-3. The experimental research methodology is based on the use of shake-table and other modern equipment for dynamic and static testing of structures. Experiments were conducted on the basis of detailed research plan and program. Efficiency of the limestone sand layer - ASL-1 was tested on cantilever concrete columns, under seismic excitations up to failure, varying the sand thickness and intensity of seismic excitation. Influence of several layer parameters on the efficiency of stone pebble layer - ASL-2 was investigated. For each considered layer parameter, a rigid model M0 was exposed to four different accelerograms, with three levels of peak ground acceleration (0.2 g, 0.4 g and 0.6 g), while all other layer parameters were kept constant. On the basis of test results, the optimal pebble layer was adopted. Afterwards, the optimal ASL-2 efficiency was tested on various model parameters: stiffness (deformable models M1-M4), foundation size (small and large), excitation type (four earthquake accelerograms), and stress level in the model (elastic and up to failure). In the ASL-3 composite aseismic layer, the optimal ASL-2 is combined with a thin additional layer of sliding material (geogrid, geomembrane above limestone sand layer), in order to achieve greater efficiency of this layer than that of the ASL-2. A total of eleven different aseismic layers were considered. To determine the optimal ASL-3, the M0 model was used, like for the ASL-2. On the basis of test results, the optimal ASL-3 layer was adopted (one higher strength geogrid at the pebble layer top). The optimal ASL-3 is tested on various model parameters, analogous to the optimal ASL-2. A numerical model for reliable seismic analysis of concrete, steel, and masonry structures with seismic base isolation using ASL-2 was developed, with innovative constitutive model for seismic isolation. The model can simulate the main nonlinear effects of mentioned materials, and was verified on performed experimental tests. In relation to the rigid base - RB without seismic isolation, model based on the ASL-1 had an average reduction in seismic force and strain/stress by approximately 10% at lower PGA levels and approximately 14% at model failure. Due to the effect of sand calcification over time, the long-term seismic efficiency of such a layer is questionable. It was concluded that the aseismic layers ASL-2 and ASL-3 are not suitable for models of medium-stiff structure M3 and soft structure M4. In relation to the RB without seismic isolation, the M1 (very stiff structure) and M2 (stiff structure) based on the ASL-2 had an average reduction in seismic force and strain/stress by approximately 13% at lower PGA levels and approximately 25% at model failure. In relation to the RB without seismic isolation, the M1 and M2 based on the ASL-3 had an average reduction in seismic force and strain/stress by approximately 25% at lower PGA levels and approximately 34% at model failure. In relation to the RB without seismic isolation, the ASL-2 and ASL-3 did not result in major M1 and M2 model displacements, which was also favourable. It is concluded that the ASL-2 and especially ASL-3 have great potential for seismic base isolation of very stiff and stiff structures, as well as small bridges based on solid ground, but further research is needed. In addition, it was concluded that the developed numerical model has great potential for practical application. Finally, further verification of the created numerical model on the results of other experimental tests is needed, but also improvement of the developed constitutive models.