scholarly journals Performance assessment of imaging plates for the JHR transfer Neutron Imaging System

2018 ◽  
Vol 170 ◽  
pp. 04021
Author(s):  
E. Simon ◽  
P. Guimbal

The underwater Neutron Imaging System to be installed in the Jules Horowitz Reactor (JHR-NIS) is based on a transfer method using a neutron activated beta-emitter like Dysprosium. The information stored in the converter is to be offline transferred on a specific imaging system, still to be defined. Solutions are currently under investigation for the JHR-NIS in order to anticipate the disappearance of radiographic films commonly used in these applications. We report here the performance assessment of Computed Radiography imagers (Imaging Plates) performed at LLB/Orphée (CEA Saclay). Several imaging plate types are studied, in one hand in the configuration involving an intimate contact with an activated dysprosium foil converter: Fuji BAS-TR, Fuji UR-1 and Carestream Flex XL Blue imaging plates, and in the other hand by using a prototypal imaging plate doped with dysprosium and thus not needing any contact with a separate converter foil. The results for these imaging plates are compared with those obtained with gadolinium doped imaging plate used in direct neutron imaging (Fuji BAS-ND). The detection performances of the different imagers are compared regarding resolution and noise. The many advantages of using imaging plates over radiographic films (high sensitivity, linear response, high dynamic range) could palliate its lower intrinsic resolution.

1991 ◽  
Vol 35 (A) ◽  
pp. 407-413 ◽  
Author(s):  
Atsushi Shibata ◽  
Katsunari Sasaki ◽  
Takao Kinefuchi

AbstractThe Fuji Imaging Plate (IP) is a 2-dimensional detector in which a latent X-ray image is stored as a distribution of color centers on a photostimulable phosphor (BaFBr:Eu2+) screen. It has a large effective area, wide dynamic range and high sensitivity. Thus it has been widely used not only in medical but also in scientific and industrial fields. Particularly in X-ray structure analysis, mainly of proteins, it has been used extensively and achieved good results.On the other hand, few applications have been reported in the field except for structure analysis, in spite of the superior performance of the IP which will give significant advantages in various measurements which have been done using an X-ray film such as electric device and fiber specimen.Therefore we report here the basic performance of R-AXIS II(Rigaku Automated X-Ray Imaging System II), an IP reader made by Rigaku, and some applications of X-ray diffraction measurements using IP.


Author(s):  
N. Mori ◽  
T. Oikawa ◽  
Y. Harada ◽  
J. Miyahara ◽  
T. Matsuo

The Imaging Plate (IP) is a new type imaging device, which was developed for diagnostic x ray imaging. We have reported that usage of the IP for a TEM has many merits; those are high sensitivity, wide dynamic range, and good linearity. However in the previous report the reading system was prototype drum-type-scanner, and IP was also experimentally made, which phosphor layer was 50μm thick with no protective layer. So special care was needed to handle them, and they were used only to make sure the basic characteristics. In this article we report the result of newly developed reading, printing system and high resolution IP for practical use. We mainly discuss the characteristics of the IP here. (Precise performance concerned with the reader and other system are reported in the other article.)Fig.1 shows the schematic cross section of the IP. The IP consists of three parts; protective layer, phosphor layer and support.


2021 ◽  
Vol 12 (1) ◽  
Author(s):  
Libo Zhang ◽  
Zhiqingzi Chen ◽  
Kaixuan Zhang ◽  
Lin Wang ◽  
Huang Xu ◽  
...  

AbstractThe advent of topological semimetals enables the exploitation of symmetry-protected topological phenomena and quantized transport. Here, we present homogeneous rectifiers, converting high-frequency electromagnetic energy into direct current, based on low-energy Dirac fermions of topological semimetal-NiTe2, with state-of-the-art efficiency already in the first implementation. Explicitly, these devices display room-temperature photosensitivity as high as 251 mA W−1 at 0.3 THz in an unbiased mode, with a photocurrent anisotropy ratio of 22, originating from the interplay between the spin-polarized surface and bulk states. Device performances in terms of broadband operation, high dynamic range, as well as their high sensitivity, validate the immense potential and unique advantages associated to the control of nonequilibrium gapless topological states via built-in electric field, electromagnetic polarization and symmetry breaking in topological semimetals. These findings pave the way for the exploitation of topological phase of matter for high-frequency operations in polarization-sensitive sensing, communications and imaging.


2012 ◽  
Vol 162 ◽  
pp. 487-496 ◽  
Author(s):  
Aurelien Yeremou Tamtsia ◽  
Youcef Mezouar ◽  
Philippe Martinet ◽  
Haman Djalo ◽  
Emmanuel Tonye

Among region-based descriptors, geometric moments have been widely exploited to design visual servoing schemes. However, they present several disadvantages such as high sensitivity to noise measurement, high dynamic range and information redundancy (since they are not computed onto orthogonal basis). In this paper, we propose to use a class of orthogonal moments (namely Legendre moments) instead of geometric moments to improve the behavior of moment-based control schemes. The descriptive form of the interaction matrix related to the Legendre moments computed from a set of points is rst derived. Six visual features are then selected to design a partially-decoupled control scheme. Finally simulated and experimental results are presented to illustrate the validity of our proposal.


2007 ◽  
Vol 98 (1) ◽  
pp. 502-512 ◽  
Author(s):  
Michael T. Lippert ◽  
Kentaroh Takagaki ◽  
Weifeng Xu ◽  
Xiaoying Huang ◽  
Jian-Young Wu

We describe methods to achieve high sensitivity in voltage-sensitive dye (VSD) imaging from rat barrel and visual cortices in vivo with the use of a blue dye RH1691 and a high dynamic range imaging device (photodiode array). With an improved staining protocol and an off-line procedure to remove pulsation artifact, the sensitivity of VSD recording is comparable with that of local field potential recording from the same location. With this sensitivity, one can record from ∼500 individual detectors, each covering an area of cortical tissue 160 μm in diameter (total imaging field ∼4 mm in diameter) and a temporal resolution of 1,600 frames/s, without multiple-trial averaging. We can record 80–100 trials of intermittent 10-s trials from each imaging field before the VSD signal reduces to one half of its initial amplitude because of bleaching and wash-out. Taken together, the methods described in this report provide a useful tool for visualizing evoked and spontaneous waves from rodent cortex.


1998 ◽  
Vol 179 ◽  
pp. 49-55
Author(s):  
T.A. McKay

The introduction of of Charge Coupled Devices (CCDs) in the middle 1970s provided astronomy with nearly perfect (linear, high-sensitivity, low-noise, high dynamic-range, digital) optical detectors. Unfortunately, restrictions imposed by CCD production and cost has typically limited their use to observations of relatively small fields. Recently a combination of technical advances have made practical the application of CCDs to survey science. CCD mosaic cameras, which help overcome the size restrictions imposed by CCD manufacture, allow electronic access to a larger fraction of the available focal plane. Multi-fiber spectrographs, which couple the low-noise, high QE performance of CCDs with the ability to observe spectra for many objects at once, have improved the spectroscopic efficiency of telescopes by factors approaching half a million. An improved understanding of image distortion gives us telescopes on which we expect sub-arcsecond images a large fraction of the time. Finally, and perhaps most important, the performance of computer hardware continues to advance, to the point where analysis of multi-terabyte datasets, while still daunting, is at least conceivable.


2012 ◽  
Vol 83 (10) ◽  
pp. 10E131 ◽  
Author(s):  
T. Caillaud ◽  
O. Landoas ◽  
M. Briat ◽  
B. Rossé ◽  
I. Thfoin ◽  
...  

2019 ◽  
Vol 64 (3) ◽  
pp. 357-363 ◽  
Author(s):  
Taha Haddadifam ◽  
Mohammad Azim Karami

Abstract Digital silicon photomultiplier (dSiPM) is introduced for diffuse optical imaging (DOI) applications instead of conventional photomultiplier tubes and avalanche photodiodes (APDs) as a state-of-the-art detector. According to the low-level light regime in DOI applications, high sensitivity and high dynamic range (DR) image sensors are needed for DOI systems. dSiPM is proposed as a developing detector which can detect low-level lights. Also, an accurate equation is obtained for calculating the DR of dSiPMs. Different dSiPMs and the corresponding benefits are studied for DOI applications. Furthermore, a 120 dB DR dSiPM is chosen for use in DOI systems. It is shown that dSiPMs can be utilized in DOI configurations such as time domain (TD), frequency domain (FD) and continuous wave (CW) systems. Ultimately, by utilizing dSiPM in DOI systems, the DOI method can be used for thoracic imaging due to the high DR and signal-to-noise ratio (SNR) of the detector.


2000 ◽  
Vol 33 (5) ◽  
pp. 1253-1261 ◽  
Author(s):  
Y. T. Cheng ◽  
D. F. R. Mildner ◽  
H. H. Chen-Mayer ◽  
V. A. Sharov ◽  
C. J. Glinka

Small-angle neutron scattering (SANS) measurements have been performed on long-flight-path pinhole-collimation SANS instruments using, as a two-dimensional position-sensitive detector, both a neutron imaging plate, incorporating gadolinium, and a two-step transfer method, with dysprosium foil as the image transfer medium. The measurements are compared with corresponding data taken using conventional position-sensitive gas proportional counters on the SANS instruments in order to assess the viability of the imaging techniques. The imaging plates have pixel sizes of about two orders of magnitude smaller than those of the gas proportional counter. The reduced pixel size provides definite advantages over the gas counter in certain specific situations, namely when limited space necessitates a short sample-to-detector distance, when only small samples (comparable in size to the detector pixels) are available, or when used in conjunction with focusing beam optics.


Sign in / Sign up

Export Citation Format

Share Document