Psychosomatic Aspects in Preparation and Follow-Up in Glaucoma Surgery and Their Special Impact on Patients

2021 ◽  
Vol 238 (02) ◽  
pp. 146-152
Author(s):  
Gabriele Maria Emmerich

AbstractGlaucoma patients often bear a long-lasting burden of disease. This can result in anxiety and stress. Causes and effects of anxiety are identified and case studies illustrate how to deal with them. Some knowledge of psychosomatic management is helpful for doctors in dealing with their patients to provide necessary treatment in a less fearful and stressful format.

2021 ◽  
Vol 10 (2) ◽  
pp. e000839
Author(s):  
Heather Cassie ◽  
Vinay Mistry ◽  
Laura Beaton ◽  
Irene Black ◽  
Janet E Clarkson ◽  
...  

ObjectivesEnsuring that healthcare is patient-centred, safe and harm free is the cornerstone of the NHS. The Scottish Patient Safety Programme (SPSP) is a national initiative to support the provision of safe, high-quality care. SPSP promotes a coordinated approach to quality improvement (QI) in primary care by providing evidence-based methods, such as the Institute for Healthcare Improvement’s Breakthrough Series Collaborative methodology. These methods are relatively untested within dentistry. The aim of this study was to evaluate the impact to inform the development and implementation of improvement collaboratives as a means for QI in primary care dentistry.DesignA multimethod study underpinned by the Theoretical Domains Framework and the Kirkpatrick model. Quantitative data were collected using baseline and follow-up questionnaires, designed to explore beliefs and behaviours towards improving quality in practice. Qualitative data were gathered using interviews with dental team members and practice-based case studies.ResultsOne hundred and eleven dental team members completed the baseline questionnaire. Follow-up questionnaires were returned by 79 team members. Twelve practices, including two case studies, participated in evaluation interviews. Findings identified positive beliefs and increased knowledge and skills towards QI, as well as increased confidence about using QI methodologies in practice. Barriers included time, poor patient and team engagement, communication and leadership. Facilitators included team working, clear roles, strong leadership, training, peer support and visible benefits. Participants’ knowledge and skills were identified as an area for improvement.ConclusionsFindings demonstrate increased knowledge, skills and confidence in relation to QI methodology and highlight areas for improvement. This is an example of partnership working between the Scottish Government and NHSScotland towards a shared ambition to provide safe care to every patient. More work is required to evaluate the sustainability and transferability of improvement collaboratives as a means for QI in dentistry and wider primary care.


Author(s):  
Hiroshi Yokoyama ◽  
Masashi Takata ◽  
Fumi Gomi

Abstract Purpose To compare clinical success rates and reductions in intraocular pressure (IOP) and IOP-lowering medication use following suture trabeculotomy ab interno (S group) or microhook trabeculotomy (μ group). Methods This retrospective review collected data from S (n = 104, 122 eyes) and μ (n = 42, 47 eyes) groups who underwent treatment between June 1, 2016, and October 31, 2019, and had 12-month follow-up data including IOP, glaucoma medications, complications, and additional IOP-lowering procedures. The Kaplan–Meier survival analysis was used to evaluate treatment success rates defined as normal IOP (> 5 to ≤ 18 mm Hg), ≥ 20% reduction of IOP from baseline at two consecutive visits, and no further glaucoma surgery. Results Schlemm’s canal opening was longer in the S group than in the μ group (P < 0.0001). The Kaplan–Meier survival analysis of all eyes showed cumulative clinical success rates in S and µ groups were 71.1% and 61.7% (P = 0.230). The Kaplan–Meier survival analysis of eyes with preoperative IOP ≥ 21 mmHg showed cumulative clinical success rates in S and μ groups were 80.4% and 60.0% (P = 0.0192). There were no significant differences in postoperative IOP at 1, 3, and 6 months (S group, 14.9 ± 5.6, 14.6 ± 4.5, 14.6 ± 3.9 mmHg; μ group, 15.8 ± 5.9, 15.2 ± 4.4, 14.7 ± 3.7 mmHg; P = 0.364, 0.443, 0.823), but postoperative IOP was significantly lower in the S group at 12 months (S group, 14.1 ± 3.1 mmHg; μ group, 15.6 ± 4.1 mmHg; P = 0.0361). There were no significant differences in postoperative numbers of glaucoma medications at 1, 3, 6, and 12 months (S group, 1.8 ± 1.6, 1.8 ± 1.5, 2.0 ± 1.6, 1.8 ± 1.5; μ group, 2.0 ± 1.6, 2.0 ± 1.6, 2.1 ± 1.6, 2.2 ± 1.7; P = 0.699, 0.420, 0.737, 0.198). Conclusion S and µ group eyes achieved IOP reduction, but μ group eyes had lower clinical success rates among patients with high preoperative IOP at 12 months.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Nea Boman ◽  
Luis Fernandez-Luque ◽  
Ekaterina Koledova ◽  
Marketta Kause ◽  
Risto Lapatto

Abstract Background A range of factors can reduce the effectiveness of treatment prescribed for the long-term management of chronic health conditions, such as growth disorders. In particular, prescription medications may not achieve the positive outcomes expected because approximately half of patients adhere poorly to the prescribed treatment regimen. Methods Adherence to treatment has previously been assessed using relatively unreliable subjective methods, such as patient self-reporting during clinical follow-up, or counting prescriptions filled or vials returned by patients. Here, we report on a new approach, the use of electronically recorded objective evidence of date, time, and dose taken which was obtained through a comprehensive eHealth ecosystem, based around the easypod™ electromechanical auto-injection device and web-based connect software. The benefits of this eHealth approach are also illustrated here by two case studies, selected from the Finnish cohort of the easypod™ Connect Observational Study (ECOS), a 5-year, open-label, observational study that enrolled children from 24 countries who were being treated with growth hormone (GH) via the auto-injection device. Results Analyses of data from 9314 records from the easypod™ connect database showed that, at each time point studied, a significantly greater proportion of female patients had high adherence (≥ 85%) than male patients (2849/3867 [74%] vs 3879/5447 [71%]; P < 0.001). Furthermore, more of the younger patients (< 10 years for girls, < 12 years for boys) were in the high adherence range (P < 0.001). However, recursive partitioning of data from ECOS identified subgroups with lower adherence to GH treatment ‒ children who performed the majority of injections themselves at an early age (~ 8 years) and teenagers starting treatment aged ≥ 14 years. Conclusions The data and case studies presented herein illustrate the importance of adherence to GH therapy and how good growth outcomes can be achieved by following treatment as described. They also show how the device, software, and database ecosystem can complement normal clinical follow-up by providing HCPs with reliable information about patient adherence between visits and also providing researchers with real-world evidence of adherence and growth outcomes across a large population of patients with growth disorders treated with GH via the easypod™ device.


2021 ◽  
Author(s):  
Frcs Ramc Breeze ◽  
William Gensheimer ◽  
Craig Berg ◽  
Kathleen M Sarber

ABSTRACT Introduction Previous analyses of head, face, and neck (HFN) surgery in the deployed military setting have focused on the treatment of injuries using trauma databases. Little has been written on the burden of disease and the requirement for follow-up care. The aim of this analysis was to provide the most comprehensive overview of surgical workload in a contemporary role 3 MTF to facilitate future planning. Method The operating room database and specialty surgical logbooks from a U.S.-led role 3 MTF in Afghanistan were analyzed over a 5-year period (2016-2020). These were then matched to the deployed surgical TC2 database to identify reasons for treatment and a return to theatre rate. Operative records were finally matched to the deployed Armed Forces Health Longitudinal Technology Application-Theater outpatient database to determine follow up frequency. Results During this period, surgical treatment to the HFN represented 389/1989 (19.6%) of all operations performed. Surgery to the HFN was most commonly performed for battle injury (299/385, 77.6%) followed by disease (63/385, 16%). The incidence of battle injury-related HFN cases varied markedly across each year, with 117/299 (39.1%) being treated in the three summer months (June to August). The burden of disease, particularly to the facial region, remained constant throughout the period analyzed (mean of 1 case per month). Conclusions Medical planning of the surgical requirements to treat HFN pathology is primarily focused on battle injury of coalition service personnel. This analysis has demonstrated that the treatment of disease represented 16% of all HFN surgical activities. The presence of multiple HFN sub-specialty surgeons prevented the requirement for multiple aeromedical evacuations of coalition service personnel which may have affected mission effectiveness as well as incurring a large financial burden. The very low volume of surgical activity demonstrated during certain periods of this analysis may have implications for the maintenance of surgical competencies for subspecialty surgeons.


2021 ◽  
pp. bjophthalmol-2021-318809
Author(s):  
Tiffany Ma ◽  
Joanne L Sims ◽  
Sonya Bennett ◽  
Shenton Chew ◽  
Rachael L Niederer

AimsTo examine presentation, management and long-term sequelae of ocular hypertension and uveitic glaucoma.MethodsRetrospective observational study of all subjects with uveitic glaucoma or ocular hypertension seen in Auckland uveitis clinics over the last 10 years.ResultsA total of 188 eyes of 139 subjects with uveitic glaucoma or ocular hypertension were included for analysis. Total follow-up was 1854.5 eye years (mean 9.9 years). The mean age at uveitis diagnosis was 49.3 years. 52.5% of subjects were male. The most common diagnoses were idiopathic uveitis (29.3%), sarcoidosis (13.3%), herpes zoster (6.9%), HLA-B27 uveitis (6.9%), tuberculosis (5.9%) and Posner-Schlossmann or cytomegalovirus (CMV) uveitis (5.3%). Median intraocular pressure (IOP) at diagnosis was 35 mm Hg (IQR 29–45). 144 eyes (77.0%) developed glaucoma during the follow-up period, of whom 41 lost some central vision due to glaucoma. Oral acetazolamide was required for IOP control in 64.5%, 50 eyes underwent trabeculectomy, 18 eyes required a tube and 6 underwent minimally invasive glaucoma surgery.ConclusionRapid progression was observed from ocular hypertension to uveitic glaucoma. Uveitic glaucoma is aggressive, with high likelihood of requiring surgical management and high risk of central vision loss. Close collaboration between uveitis and glaucoma specialists is required to maximise outcomes for these patients.


1987 ◽  
Vol 4 (4) ◽  
pp. 23-29 ◽  
Author(s):  
Brian Oldenburg

Two case studies are described where behavioural strategies, including response prevention and controlled drinking, were used to successfully treat chronic compulsive polydipsia where traditional medical management had failed. The improvement during treatment and at the 3-month follow-up was reflected not only in reduced fluid intake but also in the reduction of associated thirst symptoms and psychological distress. The implications of these results for treatment of polydipsia and non-compliance with fluid restrictions, particularly among dialysis patients, are discussed.


Author(s):  
Bryan Houliston ◽  
Nurul Sarkar

Wi-Fi (also known as IEEE 802.11b) networks are gaining widespread popularity as wireless local area networks (WLANs) due to their simplicity in operation, robustness, low cost, and user mobility offered by the technology. It is a viable technology for wireless local area networking applications in both business and home environments. This chapter reports on a survey of large New Zealand organizations focusing on the level of Wi-Fi deployment, reasons for non-deployment, the scope of deployment, investment in deployment, problems encountered, and future plans. Our findings show that most organizations have at least considered the technology, though a much smaller proportion has deployed it on any significant scale. A follow up review of the latest published case studies and surveys suggests that while Wi-Fi networks are consolidating, interest is growing in wider area wireless networks.


2020 ◽  
pp. 112067212097361
Author(s):  
Sylvain Roy ◽  
Adan Villamarin ◽  
Nikolaos Stergiopulos ◽  
André Mermoud

The eyeWatchTM is a new glaucoma drainage device that includes an adjustable mechanism that can vary the resistance to aqueous humor outflow during the postoperative period to reduce the burden of postoperative intraocular pressure (IOP) management. The mechanism contains a magnetic rotor that can be adjusted using an external magnetic control unit. Adjustments of the position of the rotor are performed mostly in the initial postoperative follow-up period in order to reach the target IOP. However, for some patients, it might be necessary to perform MRI for the sake of medical investigations. As the MRI is creating a strong magnetic field, this magnetic field is likely to interact with the adjustable rotor of the eyeWatchTM, resulting in modification of the IOP. We report the case of an 82-old female patient successfully operated with the implantation of an eyeWatchTM. The patient underwent a cerebral MRI for persistent headache. Shortly after the MRI procedure, the patient was checked at the eye clinic to assess the position of the rotor and to measure the IOP. The eyeWatchTM was readjusted to the former position set before undergoing the MRI. No complications were reported in the follow-up after MRI. This case demonstrates that MRI examinations can be safely performed after glaucoma surgery using an eyeWatchTM without compromising on the quality of the imaging or the stability of the IOP. This is a complication-free procedure that only requires checking the new position of the rotor and re-adjusting the implant, if necessary, to achieve the target IOP.