scholarly journals Effects of Denture Base Thicknesses and Reinforcement on Fracture Strength in Mandibular Implant Overdenture with Bar Attachment: Under Various Acrylic Resin Types

2019 ◽  
Vol 13 (01) ◽  
pp. 064-068
Author(s):  
Selen Tokgoz ◽  
Arda Ozdiler ◽  
Burc Gencel ◽  
Ergun Bozdag ◽  
Gulbahar Isık-Ozkol

Abstract Objective This study aimed to assess the effect of reinforcement, denture base thickness, and acrylic resin types on dynamic and static fracture strength in mandibular implant overdentures with bar attachment. Materials and Methods One hundred and eight experimental mandibular implant overdentures with bar attachments were fabricated in three main groups, namely unreinforced (control: C), reinforced with unidirectional glass fibers (FR), and Co–Cr cast metal (MR). Each group included denture bases of 2-, 3-, and 4-mm thicknesses and produced with conventional (CA) and high-impact acrylic (HIA) resins. Specimens were thermocycled (5,000 times, 5–55°C) then subjected to a 400,000 cyclic load regime. Unbroken specimens were then loaded until fracture by a universal testing machine. Differences in mean fracture resistance among the groups were compared using the one-way analysis of variance (with post hoc Tukey's honestly significant difference test) and Student's t-tests (α = 0.05). Results Fracture strength increased significantly when the denture base thickness was increased (p = 0.001). The 2-mm denture base thickness was not enough for reinforcement. The fracture strength of the FR groups was significantly higher than other groups for 3- and 4-mm thicknesses (p = 0.001). The fracture strength of the HIA resin was significantly higher than CA resin in FR groups (p = 0.029 and p = 0.001). MR groups showed the weakest fracture strength. Conclusions The 2-mm denture base thickness had sufficient fracture strength without reinforcement and a positive relationship between acrylic resin thickness and fracture resistance was found.

2018 ◽  
Vol 9 (2) ◽  
Author(s):  
Aleksandra Maletin ◽  
Jovana Bastajić ◽  
Ivan Ristić ◽  
Branislava Petronijević Šarčev ◽  
Isidora Nešković ◽  
...  

For many years, poly-methyl methacrylate has been used as a material of choice for making the denture base, thanks to its good and desirable performances, such as: simplicity in work, possibility of reparation, aesthetics and affordable price. Considering to its insufficient hardness and fracture resistance, there is a tendency to improve the mechanical properties of the material, by changing its basic composition. The aim of the research was to determine the fracture resistance of the heat-curing denture base acrylic resin materials. Materials and methods: For the research ,20 samples of the 2 heat-curing acrylics had been prepared, standard ones and reinforced acrylic resin material. After the storage in the saline for 15 days, measurements of the fracture resistance were performed by using the universal testing device. The data were statistically processed using the Student’s t-test for independent samples. Results: By measuring the flexural strength and deflection at breakage, it has been proven that there was, statistically, a significant difference of the flexural strength between reinforced (179.91-248.72MPa) and standard heat-curing acrylics (183.25- 200.74MPa). The deflection at breakage showed approximately the same values for both materials (1,0-1,4mm; 1.0-1.5mm). Conclusion: By enhancing the polymer, the mechanical properties of the denture base acrylic resin materials will be improved, primarily, higher fracture resistance, that means that these technologies need to be improved.


2015 ◽  
Vol 1 (1) ◽  
pp. 102
Author(s):  
Pramudya Aditama ◽  
Siti Sunarintyas ◽  
Widjijono Widjijono

Resin akrilik merupakan bahan yang sering digunakan dalam pembuatan basis gigi tiruan. Kelemahan resin akrilik adalah mudah patah. Salah satu cara untuk mengatasi masalah tersebut adalah dengan menambahkan polyethylene (PE) atau glass fiber. Tujuan dari penelitian ini untuk mengetahui pengaruh jenis dan volumetrik fiber terhadap kekuatan transversal reparasi plat resin akrilik. Penelitian ini menggunakan dua puluh lima plat resin akrilik kuring panas berukuran 65 x 10 x 2,5 mm. Subjek dipreparasi untuk membuat jarak 3 mm dan sudut bevel 45o. Subjek dibagi menjadi 5 kelompok, masingmasing kelompok terdiri dari 5 subjek. Kelompok 1 (kontrol) tanpa penambahan fiber, kelompok II dengan penambahan 3,7% v/v PE fiber, kelompok III dengan penambahan 7,4% v/v PE fiber, kelompok IV dengan penambahan 3,7% v/v E-glass fiber, dan kelompok V dengan penambahan 7,4% v/v E-glass fiber. Seluruh plat direndam dalam air destilasi selama satu hari pada suhu 37oC. Pengujian kekuatan transversal plat resin akrilik dengan menggunakan Universal Testing Machine dan data yang didapat dianalisis menggunakan ANAVA dua jalur dengan tingkat kepercayaan 95%. Rerata kekuatan transversal (MPa) reparasi plat resin akrilik yang diperkuat fiber: 3,7% v/v PE fiber (67,77±3,34); 7,4% v/v PE fiber (80,37±8,42); 3,7% v/v E-glass fiber (96,72±5,43); 7,4% v/v E-glass fiber (109,44±4,98); sedangkan reparasi plat resin yang tidak diperkuat fiber menghasilkan kekuatan transversal 56,27±4,7 MPa. Hasil analisis menggunakanANAVA dua jalur menunjukkan variabel jenis dan volumetrik fiber memberikan pengaruh signifikan (p<0,05), sedangkan interaksi antara jenis dan volumetrik fiber tidak berpengaruh signifikan (p>0,05). Uji post hoc Tukey menunjukkan perbedaan signifikan (p<0,05) untuk seluruh kelompok perlakuan. Penambahan E-glass fiber dalam reparasi plat resinakrilik mampu meningkatkan kekuatan transversal lebih tinggi dibandingkan dengan menggunakan PE fiber. Peningkatan volumetrik fiber dapat meningkatkan kekuatan transversal reparasi plat resin akrilik. Effect Of Type And Volumetric Fiber On Transverse Strength Of Acrylic Resin Plate Repair. Acrylic resin is the most common denture base material. A disadvantage of acrylic resin is that it is easily fractured. One way to resolve this problem is by adding polyethylene (PE) or glass fibers. The purpose of this research is to find out about the effect of type and volumetric fiber on transverse strength of acrylic resin plate repaired. The experiment involved twenty five plates of heat cured acrylic with the dimensions of 65 x 10 x 2.5 mm. The speciments were prepared to create a 3 mm gap and 45° bevel. The subjects were divided into 5 groups; each group consisted of 5. Group I (control) was without fiber reinforcement, group II reinforced with 3.7% v/v PE fiber, group III reinforced with 7.4% v/v PE fiber, group IV reinforced with 3.7% v/v E-glass fiber, and group V reinforced with 7.4% v/v E-glass fiber. All plates were soaked in distilled water for one day at 37° C temperature. The plates were tested for transverse strength with Universal Testing Machine and all data obtained were analyzed with two way ANOVA at 95% confidence level. The mean of transverse strength (MPa) of the acrylic resin plate repair reinforced with fiber: 3.7% v/v PE fiber was (67.77±3.34); 7.4% v/v PE fiber (80.37±8.42); 3.7% v/v E-glass fiber (96.72±5.43); 7.4% v/v E-glass fiber (109.44±4.98); while the transverse strength of the acrylic resin plate with no fiber reinforced was 56.27±4.7 MPa. Two way ANOVA analysis shows that type and volumetric fiber had significant effect (p<0.05), while the interaction between type and volumetric fiber had no significant effect (p>0.05). Tukey post hoc test shows significant difference (p<0.05) for all groups. The addition of E-glass fibers in the acrylic resin plate repaired increased the transverse strength higher than that with PE fibers. The increase in volumetric fibers might improve the transverse strength of the acrylic resin plate repaired.


2019 ◽  
Vol 1 (1) ◽  
pp. 35
Author(s):  
Pramudya Aditama ◽  
Erwan Sugiatno ◽  
Sabdayana Sabdayana

Acrylic resin is the most commonly used denture base material. However, it has a shortage of being easily broken. One way to resolve this problem is by adding polyethylene (PE) or glass fibers. The purpose of this research is to compare the transversal strength of PE and glass fibers from denture plate acrylic resin repair material. The experiment involved 32 plates of heat cure acrylic with the dimensions of 65 mm x 10 mm x 2.5 mm. The speciments were prepared to create a 3 mm gap and 45° bevel. Subjects were divided into 2 groups, each group containing 16 plates. Group I was reinforced with PE fiber and Group II was reinforced with glass fiber. All plates were soaked in distillation water for one day at 37 °C. Plates were tested for transverse strength with universal testing machine and all data were analyzed with independent t-tes at 95% confidence level. Macro photo analysis was used to observed the bond failure on fiber and resin. The mean of transverse strength (MPa) denture plate acrylic resin repair material reinforced with PE fiber was (67.38 ± 4.31) MPa, while glass fiber was (93.61 ± 6.14) MPa. Independent t-tes showed that type of fiber had a significant effect (p<0.05). Thus, it is possible to conclude that addition of glass fibers in denture plate acrylic resin repair material increased the transverse strength and made it stronger than those added with PE fibers.


2016 ◽  
Vol 17 (4) ◽  
pp. 322-326 ◽  
Author(s):  
M Kalavathi ◽  
Mallikarjuna Ragher ◽  
G Vinayakumar ◽  
Sanketsopan Patil ◽  
Aishwarya Chatterjee ◽  
...  

ABSTRACT Objective The objective of this study was to evaluate and compare changes in the flexural strength of heat-cured denture base resins when treated using denture cleansers. Study design A total of 40 specimens with dimension 65 mm length, 10 mm width, and 3 mm thickness were prepared as per ISO 1567 specification. A total of 10 specimens were immersed in distilled water to be used as control. Of the remaining 30 samples, 10 were treated with Clinsodent, 10 with VI-Clean, and 10 with Clanden denture cleansers. Specimens in each group were subjected to three-point flexural load in universal testing machine at a cross-head speed of 5 mm/min. The peak load (N) was recorded and flexural strength was calculated. The findings were analyzed using Kruskal–Wallis analysis of variance and Mann–Whitney test. Results Heat-cured denture base resin selected for this study showed significant difference in flexural strength after immersion in denture cleansers Clinsodent, VI-Clean, and Clanden solutions, when compared with the control group. Conclusion Findings of this study showed that denture cleansers altered the flexural strength of heat polymerized acrylic resins that endured soaking cycles which simulated 180 days of use. Hence, denture cleansers should be used with caution, once a day after brushing the dentures. It is advisable for patients to follow the manufacturer's instructions. How to cite this article Ragher M, Vinayakumar G, Patil S, Chatterjee A, Mallikarjuna DM, Dandekeri S, Swetha V, Pradeep MR. Variations in Flexural Strength of Heat-polymerized Acrylic Resin after the Usage of Denture Cleansers. J Contemp Dent Pract 2016;17(4):322-326.


2019 ◽  
Vol 2019 ◽  
pp. 1-7 ◽  
Author(s):  
Evrim Eliguzeloglu Dalkılıç ◽  
Magrur Kazak ◽  
Duygu Hisarbeyli ◽  
Mehmet Ali Fildisi ◽  
Nazmiye Donmez ◽  
...  

Objective. The aim of this study is to evaluate the effects of different fiber insertion techniques and thermomechanical aging on the fracture resistance of endodontically treated mandibular premolar teeth restored using bulk-fill composites. Materials and Methods. Eighty human mandibular premolar teeth were randomly divided into eight groups: Group IN, Group BF, Group PRF1, Group PRF2, Group IN-TMA, Group BF-TMA, Group PRF1-TMA ,and Group PRF2-TMA. Group IN (intact) and Group IN-TMA (intact but subjected to thermomechanical aging) served as control groups. In the other six groups, endodontic treatment was performed and standardized mesio-occluso-distal (MOD) cavities were prepared. In BF, PRF1, and PRF2, the cavities were restored with bulk-fill composite only, bulk-fill/Ribbond, and bulk-fill/additional Ribbond, respectively. In BF-TMA, PRF1-TMA, and PRF2-TMA, the teeth were subjected to thermomechanical aging after the restorations. All of the teeth were fractured on the universal testing machine. Fracture surfaces were analyzed with a stereomicroscope. Results. Control groups showed significantly higher fracture strengths than tested groups (P<0.05). No statistically significant difference was observed among the tested groups (P>0.05). Most of the favorable fractures were seen in PRF1, PRF2, and PRF2-TMA. Most of the unfavorable fractures were seen in BF-TMA. Conclusions. Although fiber insertion with different techniques did not increase the fracture strength of teeth restored with bulk-fill composites, it increased the favorable fracture modes. Thermomechanical aging did not change the fracture strength of the groups.


2021 ◽  
Vol 24 (3) ◽  
Author(s):  
Yousra Abdulkareem Ibraheem ◽  
Zahraa Nazar Alwahab

Objective: this in vitro study was done to evaluate  the effect of packable P60 composite and Tetric N-Ceram composite veneer material on fracture strength of zirconia cores. Material and Methods:  Twenty four zirconium cores (Vita, Germany) with 0.7 mm thickness were fabricated by CAD/CAM technology and then subjected to air abrasion with 50µm of Al2O3. Cores were randomly divided into three groups according to veneering material (group A: control group sandblasted with 50 µm Al2O3 veneered by IPS E-max Ceram porcelain, group C: sandblasted with 50 µm Al2O3,  etching with hydrofluoric acid and veneered with P60 composite, group E: sandblasted with 50 µm Al2O3, etching with hydrofluoric acid and veneered with Tetric N-Ceram composite). All crowns were subjected to fracture strength test in the testing machine, with load application by steel ball indenter and 0.5 mm/min. cross head speed. Results: statistical analysis was carried out utilizing one-way ANOVA, LSD. The results of fracture strength value test showed the highest mean value was registered for group (A), and the lowest mean for group (E). One-way ANOVA test represented that, there was a statistically high significant different among all groups. LSD results  showed a high significant difference increase in fracture resistance for Group A at p value (*P<0.001 High significant). Conclusions: Within the limitation of this study, sandblasting zirconia core with 50 µm Al2O3 and veneering with conventional ceramic produced restoration with acceptable fracture resistance value.   Keywords Composite resin; Fracture resistance; Hydrofluoric acid; IPS Emax ceram; zirconium oxide.


2018 ◽  
Vol 30 (1) ◽  
pp. 35 ◽  
Author(s):  
Edwin Tandra ◽  
Endang Wahyuningtyas ◽  
Erwan Sugiatno

Introduction: Acrylic resin is still the most commonly used denture base material due to its ideal properties. However, acrylic resin denture fractures are still considered a major unsolved problem thus the addition of nanoparticles as filler was performed to increase its mechanical properties. The purpose of this study was to discovered the effect of nanoparticles TiO2 on the flexural strength of acrylic resin denture plate. Method: This study used 27 heat-cured acrylic resin specimens sized 65 x 10 x 2.5 mm. The samples were divided into three concentration groups (n = 9), the control group; 1% of nanoparticles TiO2; and 3% of nanoparticles TiO2. The flexural strength was tested using the Universal Testing Machine. All data were analysed using the one-way ANOVA test with 95% confidence level then continued with the Least Significant Difference (LSD) test. Results: There were significant flexural strength differences in different concentration of nanoparticles TiO2. The highest flexural strength value was found in the 1% of nanoparticles TiO2 group (106.99 ± 6.09 MPa), whilst the lowest flexural strength value was found in the 3% of nanoparticles TiO2 group (91.64 ± 5.38 MPa). Significant flexural strength difference was found between the control group and the 1% of nanoparticles TiO2 group, and also between the 1% of nanoparticles TiO2 group with the 3% of nanoparticles TiO2 group (p < 0.05). Conclusion: From this study can be concluded that concentration of 1% of nanoparticles TiO2 was able to increase the flexural strength of acrylic resin denture plate.


2020 ◽  
Vol 2020 ◽  
pp. 1-12
Author(s):  
Juliana de Sá ◽  
Francisca Vieira ◽  
Carlos Manuel Aroso ◽  
Mónica Cardoso ◽  
José Manuel Mendes ◽  
...  

Aim and Background. The absorption of fluids by denture base materials diminishes the mechanical properties such as hardness, strength, and fatigue limit due to the plasticizing effect of water. This study aimed to evaluate the influence of oral pH on the fracture resistance of prosthetic bases made of three different heat-polymerizable acrylic resin brands: RS Vertex®, Triplex Hot®, and Megacryl®. The strength needed to fracture the resins and the resistance to fracture each resin were evaluated. Methods. Ten prosthesis bases prepared with each brand of resin were subjected to neutral and low pH conditions (pH 7 and pH 4) by submerging them in artificial saliva for 30 days. After exposure, the fatigue resistance of the resins was tested using a Dental CS® Testing Machine. Statistical Analysis Test. The data sets were described quantitatively in terms of mean (M) and standard deviation (SD). Shapiro–Wilk tests and unilateral analysis of variance (ANOVA) were performed and complemented by Tukey’s multiple comparison tests. The effect size (η2), whose cohort points followed Cohen’s recommendations: 0.01 (low), 0.06 (medium), and 0.14 (high), was calculated. The results were considered significant if p < 0.05 and marginally significant if p < 0.10 . Results. One-way ANOVA showed that Megacryl® had the highest fracture resistance at pH 7 (52.23 Kgf), compared with Triplex Hot® ( p < 0.001 ) and RS Vertex® ( p = 0.034 ). Two-way ANOVA confirmed the interaction between brand and pH ( p = 0.022 ), also revealing that brands comparison is significant or marginally significant, when pH is not considered (Megacryl® versus Triplex Hot®, p < 0.001 , and RS Vertex®, p = 0.058 ; Triplex Hot® versus RS Vertex®, p = 0.051 ), and pH 7 results were significantly higher ( p = 0.003 ), even when brands are not considered. Hence, Megacryl® at pH 7 was found to have the highest fracture resistance, detached from other brands and pH values. Conclusion. It can be concluded within the limitations of this study that there are differences in the fracture resistance among the three brands of acrylic resin. Megacryl® was found to have the highest fracture resistance, and Triplex Hot® was the lowest. The results also show that exposure to a low pH environment decreases the fracture resistance of the Megacryl® and RS Vertex® resins.


2017 ◽  
Vol 2 (1) ◽  
pp. 40
Author(s):  
Pramudya Aditama ◽  
Erwan Sugiatno ◽  
Muhamad Rifqi Tri Nuryanto

The effect of e-glass fiber volumetric on transverse strength of an acrylic resin denture plate repair. Acrylic resin is the most commonly material for the denture base. A disadvantage of acrylic resin is that it is easily to be cracked. One of the ways to resolve this problem is by adding the E-glass fibers. The purpose of this research was to find out the effect of volumetric E-glass fiber on transverse strength of an acrylic resin denture plate repair. The experiment involved thirty plates of heat cured acrylic with the dimensions of 65 × 10 × 2.5 mm. The specimens were prepared to create a 3-mm gap and 45° bevel. Subjects were divided in to 3 groups, each of which contained 10. Group I (control) was with no fiber reinforcement, group II was reinforced with 3.7vol % E-glass fiber, and group III was reinforced with 7.4 volume % E-glass fiber. All plates were soaked in distillation water for one day at 37 °C. Plates were tested for transverse strength with Universal Testing Machine and all data obtained was analyzed with one way anova at 95% confidence level (α= 0.05). The significant difference was found between the transversal force of acrylic resin plat enforced with fiber and other group without being reinforced with fibers (p<0.05). Group reinforced with 7.4 vol % E-glass fibers showed a significant difference (higher) than the group reinforced with 3.7 volume % fibers. The addition of E-glass fibers in an acrylic resin plate repair material increased the transverse strength. The increase in volumetric fibers might improve the transverse strength of an acrylic resin plate repair material.ABSTRAKResin akrilik merupakan bahan yang sering digunakan dalam pembuatan basis gigi tiruan. Kekurangan dari bahan resin akrilik adalah mudah patah. Salah satu cara yang dapat digunakan untuk mengatasi masalah tersebut adalah dengan menambahkan E-glass fiber. Tujuan untuk mengetahui pengaruh volumetrik E-glass fiber terhadap kekuatan transversal reparasi plat gigi tiruan resin akrilik. Penelitian ini menggunakan tiga puluh plat resin akrilik kuring panas dengan ukuran 65 × 10 × 2,5 mm. Spesimen dipreparasi untuk membentuk jarak 3 mm dan sudut bevel 45°. Subjek kemudian dibagi menjadi 3 kelompok, setiap kelompok terdiri dari 10 plat. Kelompok I (kontrol) tanpa diberikan penguat fiber, kelompok II diperkuat dengan 3,7 vol % E-glass  ber, dan kelompok III diperkuat dengan 7,4 vol % E-glass fiber. Seluruh plat kemudian direndam dalam air destilasi selama satu hari pada suhu 37 °C. Plat resin akrilik kemudian diuji menggunakan Universal Testing Machine untuk mengetahui kekuatan transversal dan data yang didapatkan dianalisis menggunakan Anova satu jalur dengan tingkat kepercayaan 95% (α=0,05). Hasil menunjukkan terdapat perbedaan signifikan antara kekuatan transversal plat resin akrilik yang diperkuat dengan fiber dengan kelompok tanpa diperkuat fiber (p < 0,05). Kelompok yang diperkuat dengan 7,4 vol % E-glass fiber menunjukkan perbedaan signi kan (lebih tinggi) dibandingkan kelompok yang diperkuat dengan 3,7 vol % fiber. Kesimpulan bahwa peningkatan volume dari E-glass fiber dapat meningkatkan kekuatan transversal reparasi plat gigi tiruan resin akrilik.


2020 ◽  
Vol 14 (1) ◽  
pp. 681-686
Author(s):  
Mohammed Mustafa ◽  
Zaid A. AlJeaidi ◽  
Ali Robaian AlQahtani ◽  
Mohammed Ali Salem Abuelqomsan ◽  
Raneem Suleiman Alofi ◽  
...  

Background: A perfect balance needs to be maintained between various types of endodontic access cavity preparation designs like - Traditional and conservative designed preparation to have access to the root canal system for proper cleaning and shaping of root canals without compromising the fracture resistance of the tooth structure. Aims and Objectives: We aimed to assess as well as draw comparisons of resistance against fracture of remaining tooth structure post the endodontic treatment after preparing access cavity through a variety of techniques so that we can estimate which type of cavity design technique will help endodontically treated teeth to withstand excessive load without fracture. Methods: Forty-two intact teeth (mandibular molars) were randomly selected and then were assigned to 07 different groups, inclusive of control and test groups. Various designs of access cavity preparation were done on sample teeth. The groups were divided based on different access cavity preparation designs as well as residual walls. The samples were then mounted on a composite cylinder, which was loaded under a mechanical testing machine at 0.5mm/min speed till the tooth structure fractured. This measurement of force was denoted in newton. The later analysis was carried out with the help of two-way Analysis of Variance (ANOVA) as well as Tukey’s post-hoc statistical tests. Results: There was negligible statistically relevant variance in strength towards fracture between traditional and conservative designs in teeth having three remaining walls. However, teeth with only two remaining walls fractured easily. Conclusion: Fracture resistance of teeth with remaining 03 residual walls did not show any significant difference among Traditional (TEC) and Conservative Cavity (CEC) design groups, but increased fracture strength was reported in CEC with 02 residual walls.


Sign in / Sign up