scholarly journals Numerical Model for Decontamination of Organic Contaminants in Polyethylene Drinking Water Pipes in Premise Plumbing by Flushing

2019 ◽  
Vol 145 (7) ◽  
pp. 04019034 ◽  
Author(s):  
Levi M. Haupert ◽  
Matthew L. Magnuson
Author(s):  
Gabriel Pablo Lobo ◽  
Ashok Gadgil

Toxic levels of lead leaching from ageing water distribution infrastructure affect over 5,000 public drinking water systems in the US. Pipe replacement, the most effective solution to this problem, is...


Agriculture ◽  
2020 ◽  
Vol 10 (3) ◽  
pp. 86
Author(s):  
Regina Böger ◽  
Karl Rohn ◽  
Nicole Kemper ◽  
Jochen Schulz

Poor drinking water quality can affect pigs’ health and performance. The disinfection of water may enhance microbial water quality. In this study, bacteria and endotoxins in sodium hypochlorite-treated and -untreated water from one pig nursery were analyzed. Water samples were taken from incoming water and from compartments with treated and untreated water at the beginning and end of pipes and from nipples. The farm was visited 14 times to measure total bacteria counts and concentrations of Pseudomonas spp. and endotoxins. Additionally, the occurrence of coliform bacteria was analyzed. A mixed model analysis revealed significant reductions in total bacteria counts and Pseudomonas spp. in treated water at the beginning of pipes and at nipple drinkers. The differences between bacteria concentrations at the end of pipes had no clear trend. Endotoxin concentrations were approximately equal at the beginning of pipes and at nipple drinkers but were found to have differences at the end of pipes. The occurrence of coliform bacteria was significantly reduced in treated water. The application of sodium hypochlorite can significantly reduce bacteria in water pipes. Endotoxin concentrations were mostly unaffected by water treatment. Disinfection of the dead-end pipe sections failed, and thus these parts should be regarded as potential contamination sources.


Opflow ◽  
2021 ◽  
Vol 47 (8) ◽  
pp. 20-22
Author(s):  
Min Tang ◽  
Michael R. Schock ◽  
Helen Y. Buse ◽  
Darren A. Lytle ◽  
Robert E. Fields ◽  
...  
Keyword(s):  

2019 ◽  
Vol 53 (22) ◽  
pp. 13293-13301 ◽  
Author(s):  
Andreas Wimmer ◽  
Jessica Beyerl ◽  
Michael Schuster
Keyword(s):  

Pathogens ◽  
2020 ◽  
Vol 9 (11) ◽  
pp. 957
Author(s):  
Abraham C. Cullom ◽  
Rebekah L. Martin ◽  
Yang Song ◽  
Krista Williams ◽  
Amanda Williams ◽  
...  

Growth of Legionella pneumophila and other opportunistic pathogens (OPs) in drinking water premise plumbing poses an increasing public health concern. Premise plumbing is constructed of a variety of materials, creating complex environments that vary chemically, microbiologically, spatially, and temporally in a manner likely to influence survival and growth of OPs. Here we systematically review the literature to critically examine the varied effects of common metallic (copper, iron) and plastic (PVC, cross-linked polyethylene (PEX)) pipe materials on factors influencing OP growth in drinking water, including nutrient availability, disinfectant levels, and the composition of the broader microbiome. Plastic pipes can leach organic carbon, but demonstrate a lower disinfectant demand and fewer water chemistry interactions. Iron pipes may provide OPs with nutrients directly or indirectly, exhibiting a high disinfectant demand and potential to form scales with high surface areas suitable for biofilm colonization. While copper pipes are known for their antimicrobial properties, evidence of their efficacy for OP control is inconsistent. Under some circumstances, copper’s interactions with premise plumbing water chemistry and resident microbes can encourage growth of OPs. Plumbing design, configuration, and operation can be manipulated to control such interactions and health outcomes. Influences of pipe materials on OP physiology should also be considered, including the possibility of influencing virulence and antibiotic resistance. In conclusion, all known pipe materials have a potential to either stimulate or inhibit OP growth, depending on the circumstances. This review delineates some of these circumstances and informs future research and guidance towards effective deployment of pipe materials for control of OPs.


2019 ◽  
Vol 17 (6) ◽  
pp. 870-883 ◽  
Author(s):  
Isabelle Schmidt ◽  
Bettina Rickert ◽  
Oliver Schmoll ◽  
Thomas Rapp

Abstract The World Health Organization (WHO) promotes water safety plans (WSPs) – a risk-based management approach – for premise plumbing systems in buildings to prevent deterioration of drinking-water quality. Experience with the implementation of WSPs in buildings were gathered within a pilot project in Germany. The project included an evaluation of the feasibility and advantages of WSPs by all stakeholders who share responsibility in drinking-water safety. While the feasibility of the concept was demonstrated for all buildings, benefits reported by building operators varied. The more technical standards were complied with before implementing WSP, the less pronounced were the resulting improvements. In most cases, WSPs yielded an increased system knowledge and awareness for drinking-water quality issues. WSPs also led to improved operation of the premise plumbing system and provided benefits for surveillance authorities. A survey among the European Network of Drinking-Water Regulators on the existing legal framework regarding drinking-water safety in buildings exhibited that countries are aware of the need to manage risks in buildings' installations, but experience with WSP is rare. Based on the successful implementation and the positive effects of WSPs on drinking-water quality, we recommend the establishment of legal frameworks that require WSPs for priority buildings whilst accounting for differing conditions in buildings and countries.


2012 ◽  
Vol 12 (4) ◽  
pp. 470-479 ◽  
Author(s):  
Rey Gutiérrez ◽  
Salvador Vega ◽  
Rutilio Ortiz ◽  
Beatriz Schettino

Concentrations of organic contaminants (organochlorine pesticides and biphenyls) were studied in bottled drinking water (BDW) from Mexico City where consumption is high and considered a healthy alternative to the potable water network. The results of 36 samples (1.5 L and 19 L presentations, 18 samples of each) showed the presence of seven pesticides (HCH-hexachlorocyclohexane isomers, heptachlor, aldrin and p,p'-DDE'-dichlorodiphenyldichloroethylene) and some polychlorinated biphenyls-PCBs (28, 58 and 101). The concentrations were compared with the drinking water standards set by NOM-127-SSA1–1994, USEPA (United States Environment Protection Agency) and the World Health Organization (WHO) for pesticides and NOM-127-SSA1–1994 for biphenyls. The concentrations of the majority of organochlorine pesticides were within drinking water standards (0.01 μg L−1) except for β-HCH in BDW samples 3, 5 and 6 with values of 0.121, 0.136 and 0.192 μg L−1, respectively. The total PCBs concentration in BDW did not represent any hazard to human health, according to Mexican regulations, which establish a maximum permissible level of 0.50 μg L−1. A BDW quality monitoring program is recommended and further research on ways of reducing the presence of organochlorine contaminants to prevent bioaccumulation and toxicological effects over population with emphasis in those that with constant consumption.


Sign in / Sign up

Export Citation Format

Share Document