Qualification of a high-efficiency, gated spectrometer for x-ray Thomson scattering on the National Ignition Facility

2014 ◽  
Vol 85 (11) ◽  
pp. 11D617 ◽  
Author(s):  
T. Döppner ◽  
A. L. Kritcher ◽  
P. Neumayer ◽  
D. Kraus ◽  
B. Bachmann ◽  
...  
2016 ◽  
Vol 87 (11) ◽  
pp. 11E515 ◽  
Author(s):  
T. Döppner ◽  
D. Kraus ◽  
P. Neumayer ◽  
B. Bachmann ◽  
J. Emig ◽  
...  

2013 ◽  
Vol 15 (8) ◽  
pp. 755-759
Author(s):  
Xiaoding Zhang ◽  
Jiyan Zhang ◽  
Guohong Yang ◽  
Minxi Wei ◽  
Guangyue Hu ◽  
...  

2014 ◽  
Vol 21 (8) ◽  
pp. 082709 ◽  
Author(s):  
D. A. Chapman ◽  
D. Kraus ◽  
A. L. Kritcher ◽  
B. Bachmann ◽  
G. W. Collins ◽  
...  

Sensors ◽  
2021 ◽  
Vol 21 (1) ◽  
pp. 238
Author(s):  
Jakub Šalplachta ◽  
Tomáš Zikmund ◽  
Marek Zemek ◽  
Adam Břínek ◽  
Yoshihiro Takeda ◽  
...  

In this article, we introduce a new ring artifacts reduction procedure that combines several ideas from existing methods into one complex and robust approach with a goal to overcome their individual weaknesses and limitations. The procedure differentiates two types of ring artifacts according to their cause and character in computed tomography (CT) data. Each type is then addressed separately in the sinogram domain. The novel iterative schemes based on relative total variations (RTV) were integrated to detect the artifacts. The correction process uses the image inpainting, and the intensity deviations smoothing method. The procedure was implemented in scope of lab-based X-ray nano CT with detection systems based on charge-coupled device (CCD) and scientific complementary metal–oxide–semiconductor (sCMOS) technologies. The procedure was then further tested and optimized on the simulated data and the real CT data of selected samples with different compositions. The performance of the procedure was quantitatively evaluated in terms of the artifacts’ detection accuracy, the comparison with existing methods, and the ability to preserve spatial resolution. The results show a high efficiency of ring removal and the preservation of the original sample’s structure.


Instruments ◽  
2021 ◽  
Vol 5 (2) ◽  
pp. 17
Author(s):  
Eldred Lee ◽  
Kaitlin M. Anagnost ◽  
Zhehui Wang ◽  
Michael R. James ◽  
Eric R. Fossum ◽  
...  

High-energy (>20 keV) X-ray photon detection at high quantum yield, high spatial resolution, and short response time has long been an important area of study in physics. Scintillation is a prevalent method but limited in various ways. Directly detecting high-energy X-ray photons has been a challenge to this day, mainly due to low photon-to-photoelectron conversion efficiencies. Commercially available state-of-the-art Si direct detection products such as the Si charge-coupled device (CCD) are inefficient for >10 keV photons. Here, we present Monte Carlo simulation results and analyses to introduce a highly effective yet simple high-energy X-ray detection concept with significantly enhanced photon-to-electron conversion efficiencies composed of two layers: a top high-Z photon energy attenuation layer (PAL) and a bottom Si detector. We use the principle of photon energy down conversion, where high-energy X-ray photon energies are attenuated down to ≤10 keV via inelastic scattering suitable for efficient photoelectric absorption by Si. Our Monte Carlo simulation results demonstrate that a 10–30× increase in quantum yield can be achieved using PbTe PAL on Si, potentially advancing high-resolution, high-efficiency X-ray detection using PAL-enhanced Si CMOS image sensors.


2021 ◽  
Vol 11 (10) ◽  
pp. 4349
Author(s):  
Tianzhong Xiong ◽  
Wenhua Ye ◽  
Xiang Xu

As an important part of pretreatment before recycling, sorting has a great impact on the quality, efficiency, cost and difficulty of recycling. In this paper, dual-energy X-ray transmission (DE-XRT) combined with variable gas-ejection is used to improve the quality and efficiency of in-line automatic sorting of waste non-ferrous metals. A method was proposed to judge the sorting ability, identify the types, and calculate the mass and center-of-gravity coordinates according to the shading of low-energy, the line scan direction coordinate and transparency natural logarithm ratio of low energy to high energy (R_value). The material identification was satisfied by the nearest neighbor algorithm of effective points in the material range to the R_value calibration surface. The flow-process of identification was also presented. Based on the thickness of the calibration surface, the material mass and center-of-gravity coordinates were calculated. The feasibility of controlling material falling points by variable gas-ejection was analyzed. The experimental verification of self-made materials showed that identification accuracy by count basis was 85%, mass and center-of-gravity coordinates calculation errors were both below 5%. The method proposed features high accuracy, high efficiency, and low operation cost and is of great application value even to other solid waste sorting, such as plastics, glass and ceramics.


2019 ◽  
Vol 26 (6) ◽  
pp. 063105 ◽  
Author(s):  
M. J. May ◽  
G. E. Kemp ◽  
J. D. Colvin ◽  
D. A. Liedahl ◽  
P. L. Poole ◽  
...  

Author(s):  
Chuanxiang Tang ◽  
Wenhui Huang ◽  
Renkai Li ◽  
Yingchao Du ◽  
Lixin Yan ◽  
...  
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document