The simulation of temperature distribution and relative humidity with liquid concentration of 50% using computational fluid dynamics

2015 ◽  
Author(s):  
Eflita Yohana ◽  
Mohamad Endy Yulianto ◽  
Choi Kwang-Hwang ◽  
Bondantio Putro ◽  
Yohanes Aditya W. A.
2020 ◽  
Vol 8 (1) ◽  
Author(s):  
Tim Padfield ◽  
Nicolas Padfield ◽  
Daniel Sang-Hoon Lee ◽  
Anne Thøgersen ◽  
Astrid Valbjørn Nielsen ◽  
...  

Abstract In this paper different scenarios for back protection of a canvas painting and their effect on the stability of the relative humidity behind the painting are tested. A painting on canvas, stretched on a wooden frame, was fitted with various styles of back protection and then exposed to a cycle of temperature variation at the back, with the front exposed to a constant room temperature. The painting was also exposed to a constant wall temperature and varying room temperature. The space between the canvas and the back board was fitted with temperature and relative humidity (RH) sensors. The sensors were used to provide the essential single-point data of temperature and RH at the given locations. For more comprehensive understanding of the rather confined space, further numerical simulation (computational fluid dynamics) was adopted as part of the investigation. The computational fluid dynamics was used to understand the natural convection within the microclimate through the depictions of temperature distribution, as well as the corresponding airflow. The unprotected painting suffered a large RH variation at its back, because of the varying canvas temperature interacting with the constant room air moisture content. Effective stabilisation of the RH behind the canvas against temperature variation was provided by a shiny aluminium alloy sheet sealed against the frame. The non-absorbent back board experienced a strong variation in RH, because of humidity buffering of the space by the painting canvas at a different temperature. Either a space or insulation between this back plate and the wall reduced the risk of condensation on the inner surface of the back plate. Insulation will however increase the risk of condensation on the wall surface behind the painting. An absorbent back board de-stabilised the RH at the painting canvas surface by providing a competing humidity buffer at a different temperature. To provide protection against moisture exchange with an unsuitable room RH, extra humidity buffer was placed 3 mm behind the painting canvas, kept close to the painting temperature by insulation between this buffer and the back board. This stabilised RH at the canvas surface but increased both the temperature and the RH variation at the back board and thus increased the risk of condensation on the inner surface of the back board. The RH and the temperature in the narrow spaces between the painting canvas and the wooden stretcher frame were always more nearly constant than in the open canvas area, which suggests an explanation for the widely observed better condition of the areas of canvas paintings which lie close over the support structure. Our conclusion is that a non-absorbent, impermeable back plate gives good RH stability against a changing temperature gradient between wall and canvas painting surface.


2021 ◽  
Author(s):  
Eleonora Bottani ◽  
Roberto Montanari ◽  
Andrea Volpi ◽  
Giulio Di Maria ◽  
Federico Solari ◽  
...  

COVID-19 brought several management problems, and among these surely the topic of Personal Protective Equipment (PPE) turned out to be crucial. Indeed, in the light of mandatory measurements adopted by governments both for private individuals and companies, their demand has rapidly increased, thus generating shortages, increased waste and unbalanced prices. In response to that, many industrial fields offered their tools and know-how for trying to partly face this issue, and in this paper part of a solution of this kind is presented. Specifically, it is meant the redesign of a food oven produced by an Italian company operating in the food sector (Nilma S.p.A.) for thermal sanitization against the virus in question. In this paper, the simulation of the temperature distribution inside the chamber is simulated, with subsequent experimental validation at 95°C.


2016 ◽  
Vol 826 ◽  
pp. 99-104
Author(s):  
Guang Rui Jiang ◽  
Li Bin Liu ◽  
Huang Xiang Teng ◽  
Fang Qing Kong

s In this study, Computational Fluid Dynamics (CFD) was used to simulate the flow and temperature distribution in zinc pot of hot-dip galvanizing process. The flow and temperature distribution in a base-case zinc pot was compared to that in other two optimized zinc pots, one of which had a dam between ingot and snout and another one had a reduced heating power. The simulation shows that the dam impedes the flow of low temperature liquid zinc around zinc ingot to strip and increases the fluctuation of zinc level. By reducing the heating power, however, the fluctuation of zinc level could be suppressed.


2010 ◽  
Vol 439-440 ◽  
pp. 880-883
Author(s):  
Fu Zhao ◽  
Ping Wang ◽  
Yan Jue Gong ◽  
Yu De Liu ◽  
Hong Bin Xin

With the three-dimensional computational fluid dynamics method, the airflow effects over the huge telescope assemble is investigated in this article. The distributing of velocity field and natural convection are studied by modeling and simulating the turbulent airflow of the huge telescope. Numerical simulations show the best observation direction is the 90o angle between the main optics axis and the horizontal line in which the air velocity distribution is the least. And the air temperature distribution and uniformity around the telescope are also provided by simulation.


1996 ◽  
Vol 14 (3) ◽  
pp. 186-198 ◽  
Author(s):  
W.K. Chow

The multi-cell concept is applied to simulate fire in a big com partment with the zone model CFAST. The predicted physical properties of the smoke layer are used to justify the results, including the smoke layer tempera ture, smoke layer thickness and flows between each cell. Microscopic pictures of the flow pattern and smoke temperature distribution similar to the results pre dicted by the Computational Fluid Dynamics technique can be obtained. This idea is recommended to study fires in big enclosures.


Author(s):  
Michael A. Porter ◽  
Dennis H. Martens ◽  
Thomas Duffy ◽  
Sean McGuffie

Many modern Sulfur Recovery Unit (SRU) process waste heat recovery exchangers operate in high temperature environments. These exchangers are associated with the thermal reactor system where the tubesheet/tube/ferrule assemblies are exposed to gasses at temperatures approaching 3000°F. Because sulfur compounds are present in the process gas, the carbon steel tubesheet and tubes in the assembly will be deteriorated by sulfidation as the operating metal temperature rises above 600°F. Ferrule systems are used to protect the carbon steel from exposure to excessive temperatures. The temperature distribution in the steel tubesheet/tube/ferrule system is affected by process gas flow and heat transfer through the assembly. Rather than depend upon “assumed” heat transfer coefficients and fluid flow distribution, a Computational Fluid Dynamics (CFD) investigation was conducted to study the flow fields and heat transfer in the tubesheet assembly. It was found that the configuration of the ferrule installation has a large influence on the temperature distribution in the steel materials and, therefore, the possible sulfidation of the carbon steel parts.


TAPPI Journal ◽  
2020 ◽  
Vol 19 (6) ◽  
pp. 303-316
Author(s):  
KUNAL KUMAR ◽  
VILJAMI MAAKALA ◽  
VILLE VUORINEN

Superheaters are the last heat exchangers on the steam side in recovery boilers. They are typically made of expensive materials due to the high steam temperature and risks associated with ash-induced corrosion. Therefore, detailed knowledge about the steam properties and material temperature distribution is essential for improving the energy efficiency, cost efficiency, and safety of recovery boilers. In this work, for the first time, a comprehensive one-dimensional (1D) process model (1D-PM) for a superheated steam cycle is developed and linked with a full-scale three-dimensional (3D) computational fluid dynamics (CFD) model of the superheater region flue gas flow. The results indicate that: (1) the geometries of headers and superheater platens affect platen-wise steam mass flow rate distribution (3%–7%); and (2) the CFD solution of the 3D flue gas flow field and platen heat flux distribution coupled with the 1D-PM affect the platen-wise steam superheating temperature (45%–122%) and material temperature distribution (1%–6%). Moreover, it is also found that the commonly-used uniform heat flux distribution approach for the superheating process is not accurate, as it does not consider the effect of flue gas flow field in the superheater region. These new observations clearly demonstrate the value of the present integrated CFD/1D-PM modeling approach.


Sign in / Sign up

Export Citation Format

Share Document