scholarly journals Comprehensive pregnancy monitoring with a network of wireless, soft, and flexible sensors in high- and low-resource health settings

2021 ◽  
Vol 118 (20) ◽  
pp. e2100466118
Author(s):  
Dennis Ryu ◽  
Dong Hyun Kim ◽  
Joan T. Price ◽  
Jong Yoon Lee ◽  
Ha Uk Chung ◽  
...  

Vital signs monitoring is a fundamental component of ensuring the health and safety of women and newborns during pregnancy, labor, and childbirth. This monitoring is often the first step in early detection of pregnancy abnormalities, providing an opportunity for prompt, effective intervention to prevent maternal and neonatal morbidity and mortality. Contemporary pregnancy monitoring systems require numerous devices wired to large base units; at least five separate devices with distinct user interfaces are commonly used to detect uterine contractility, maternal blood oxygenation, temperature, heart rate, blood pressure, and fetal heart rate. Current monitoring technologies are expensive and complex with implementation challenges in low-resource settings where maternal morbidity and mortality is the greatest. We present an integrated monitoring platform leveraging advanced flexible electronics, wireless connectivity, and compatibility with a wide range of low-cost mobile devices. Three flexible, soft, and low-profile sensors offer comprehensive vital signs monitoring for both women and fetuses with time-synchronized operation, including advanced parameters such as continuous cuffless blood pressure, electrohysterography-derived uterine monitoring, and automated body position classification. Successful field trials of pregnant women between 25 and 41 wk of gestation in both high-resource settings (n = 91) and low-resource settings (n = 485) demonstrate the system’s performance, usability, and safety.

Author(s):  
Muhammad Niswar ◽  
Muhammad Nur ◽  
Idar Mappangara

Medical devices are often expensive, so people in low-income countries cannot afford them. This paper presents the design of a low-cost wearable medical device to measure vital signs of a patient including heart rate, blood oxygen saturation level (SpO2) and respiratory rate. The wearable medical device mainly consists of a microcontroller and two biomedical sensors including airflow thermal sensor to measure respiratory rate and pulse oximeter sensor to measure SpO2 and heart rate. We can monitor the vital signs from a smartphone using a web browser through IEEE802.11 wireless connectivity to the wearable medical device. Furthermore, the wearable medical device requires simple management to operate; hence, it can be easily used. Performance evaluation results show that the designed wearable medical device works as good as a standard SpO2 device and it can measure the respiratory rate properly.  The designed wearable medical device is inexpensive and appropriate for low-resource settings. Moreover, as its components are commonly available in the market, it easy to assembly and repair locally.


2020 ◽  
Vol 6 (2) ◽  
pp. 55-71 ◽  
Author(s):  
Stephanie Soon ◽  
Hafdis Svavarsdottir ◽  
Candice Downey ◽  
David George Jayne

Early detection of physiological deterioration has been shown to improve patient outcomes. Due to recent improvements in technology, comprehensive outpatient vital signs monitoring is now possible. This is the first review to collate information on all wearable devices on the market for outpatient physiological monitoring.A scoping review was undertaken. The monitors reviewed were limited to those that can function in the outpatient setting with minimal restrictions on the patient’s normal lifestyle, while measuring any or all of the vital signs: heart rate, ECG, oxygen saturation, respiration rate, blood pressure and temperature.A total of 270 papers were included in the review. Thirty wearable monitors were examined: 6 patches, 3 clothing-based monitors, 4 chest straps, 2 upper arm bands and 15 wristbands. The monitoring of vital signs in the outpatient setting is a developing field with differing levels of evidence for each monitor. The most common clinical application was heart rate monitoring. Blood pressure and oxygen saturation measurements were the least common applications. There is a need for clinical validation studies in the outpatient setting to prove the potential of many of the monitors identified.Research in this area is in its infancy. Future research should look at aggregating the results of validity and reliability and patient outcome studies for each monitor and between different devices. This would provide a more holistic overview of the potential for the clinical use of each device.


Micromachines ◽  
2021 ◽  
Vol 12 (8) ◽  
pp. 918
Author(s):  
Siraporn Sakphrom ◽  
Thunyawat Limpiti ◽  
Krit Funsian ◽  
Srawouth Chandhaket ◽  
Rina Haiges ◽  
...  

This article presents the design of a low-cost Wireless Body Sensor Network (WBSN) for monitoring vital signs including a low-cost smart wristwatch that contains an ESP-32 microcontroller and three sensors: heart rate (HR), blood pressure (BP) and body temperature (BT), and an Internet of Things (IoT) platform. The vital signs data are processed and displayed on an OLED screen of the patient’s wristwatch and sent the data over a wireless connection (Wi-Fi) and a Cloud Thing Board system, to store and manage the data in a data center. The data can be analyzed and notified to medical staff when abnormal signals are received from the sensors based on a set parameters from specialists. The proposed low-cost system can be used in a wide range of applications including field hospitals for asymptotic or mild-condition COVID-19 patients as the system can be used to screen those patients out of symptomatic patients who require more costly facilities in a hospital with considerably low expense and installation time, also suitable for bedridden patients, palliative care patients, etc. Testing experiments of a 60-person sample size showed an acceptable accuracy level compared with standard devices when testing with 60 patient-samples with the mean errors heart rate of 1.22%, systolic blood pressure of 1.39%, diastolic blood pressure of 1.01%, and body temperature of 0.13%. According to testing results with 10 smart devices connected with the platform, the time delay caused by the distance between smart devices and the router is 10 s each round with the longest outdoor distance of 200 m. As there is a short-time delay, it does not affect the working ability of the smart system. It is still making the proposed system be able to show patient’s status and function in emergency cases.


2020 ◽  
Vol 79 (Suppl 1) ◽  
pp. 914.2-914
Author(s):  
S. Boussaid ◽  
M. Ben Majdouba ◽  
S. Jriri ◽  
M. Abbes ◽  
S. Jammali ◽  
...  

Background:Music therapy is based on ancient cross-cultural beliefs that music can have a “healing” effect on mind and body. Research determined that listening to music can increase comfort and relaxation, relieve pain, lower distress, reduce anxiety, improve positive emotions and mood, and decrease psychological symptoms. Music therapy has been used greatly in various medical procedures to reduce associated anxiety and pain. Patients have a high level of anxiety when they are in the hospital, this is the case of patients with rheumatic diseases who consult regularly to have intravenous infusion of biological therapies.Objectives:The purpose of this study was to examine the effectiveness of music therapy on pain, anxiety, and vital signs among patients with chronic inflammatory rheumatic diseases during intravenous infusion of biological drugs.Methods:Fifty patients were divided into two groups: The experimental group G1 (n=25) received drug infusion while lestening to soft music (30 minutes); and the control group G2 (n=25) received only drug infusion. Measures include pain, anxiety, vital signs (blood pressure, heart rate and respiratory rate). The pain was measured using visual analogic scale (VAS). The state-trait anxiety inventory (STAI) was used for measuring anxiety, low anxiety ranges from 20 to 39, the moderate anxiety ranges from 40 to 59, and high anxiety ranges from 60 to 80. Vital signs (systolic blood pressure [SBP], diastolic blood pressure [DBP], heart rate [HR], and respiratory rate [RR]) were measured before, during and immediately after the infusion.Statistical package for social sciences (SPSS) was used for analysis.Results:The mean age in G1 was 44.45 years (26-72) with a sex ratio (M/F) of 0.8. Including the 25 patients, 12 had rheumatoid arthritis, 10 had ankylosing spondylitis and 3 had psoriatic arthritis. The mean disease duration was 8 years. In G2, the mean age was 46 years (25-70) with a sex ratio (M/F) of 0.75, 12 had rheumatoid arthritis, 11 had ankylosing spondylitis and 2 had psoriatic arthritis. The mean disease duration was 7.5 years. The biological drugs used were: Infliximab in 30 cases, Tocilizumab in 12 cases and Rituximab in 8 cases.Before the infusion, the patients of experimental group had a mean VAS of 5/10±3, a mean STAI of 50.62±6.01, a mean SBP of 13.6 cmHg±1.4, a mean DBP of 8.6 cmHg±1, a mean HR of 85±10 and a mean RR of 18±3. While in control group the mean VAS was 5.5±2, the mean STAI was 50.89±5.5, the mean SBP was 13.4±1.2, the mean DBP was 8.8±1.1, the mean HR was 82±8 and the mean RR was 19±2.During the infusion and after music intervention in G1, the mean STAI became 38.35±5 in G1 versus 46.7±5.2 in G2 (p value=0.022), the mean SBP became 12.1±0.5 in G1 versus 13±1 in G2 (p=0.035), the mean DBP became 8.1±0.8 in G1 versus 8.4±0.9 in G2 (p=0.4), the mean HR became 76±9 in G1 versus 78±7 in G2 (p=0.04) and the mean RR became 17.3±2.1 in G1 versus 18.2±1.7 in G2 (p=0.39).This study found a statistically significant decrease in anxiety, systolic blood pressure and heart rate in patients receiving music interventions during biological therapies infusion, but no significant difference were identified in diastolic blood pressure and respiratory rate.Conclusion:The findings provide further evidence to support the use of music therapy to reduce anxiety, and lower systolic blood pressure and heart rate in patients with rheumatic disease during biological therapies infusion.References:[1] Lin, C., Hwang, S., Jiang, P., & Hsiung, N. (2019).Effect of Music Therapy on Pain After Orthopedic Surgery -A Systematic review and Meta-Analysis. Pain Practice.Disclosure of Interests:None declared


Author(s):  
Seung-Ho Park ◽  
Kyoung-Su Park

Abstract As the importance of continuous vital signs monitoring increases, the need for wearable devices to measure vital sign is increasing. In this study, the device is designed to measure blood pressure (BP), respiratory rate (RR), and heartrate (HR) with one sensor. The device is in earphone format and is manufactured as wireless type using Arduino-based bluetooth module. The device measures pulse signal in the Superficial temporal artery using Photoplethysmograghy (PPG) sensor. The device uses the Auto Encoder to remove noise caused by movement, etc., contained in the pulse signal. Extract the feature from the pulse signal and use them for the vital sign measurement. The device is measured using Slope transit time (STT) method for BP and Respiratory sinus arrhythmia (RSA) method for RR. Finally, the accuracy is determined by comparing the vital signs measured through the device with the reference vital signs measured simultaneously.


2020 ◽  
Vol 12 (14) ◽  
pp. 2279 ◽  
Author(s):  
Shekh Md Mahmudul Islam ◽  
Olga Borić-Lubecke ◽  
Yao Zheng ◽  
Victor M. Lubecke

Non-contact vital signs monitoring using microwave Doppler radar has shown great promise in healthcare applications. Recently, this unobtrusive form of physiological sensing has also been gaining attention for its potential for continuous identity authentication, which can reduce the vulnerability of traditional one-pass validation authentication systems. Physiological Doppler radar is an attractive approach for continuous identity authentication as it requires neither contact nor line-of-sight and does not give rise to privacy concerns associated with video imaging. This paper presents a review of recent advances in radar-based identity authentication systems. It includes an evaluation of the applicability of different research efforts in authentication using respiratory patterns and heart-based dynamics. It also identifies aspects of future research required to address remaining challenges in applying unobtrusive respiration-based or heart-based identity authentication to practical systems. With the advancement of machine learning and artificial intelligence, radar-based continuous authentication can grow to serve a wide range of valuable functions in society.


2019 ◽  
Vol 4 (1) ◽  
pp. 625-628
Author(s):  
Nisha Ghimire ◽  
Renu Yadav ◽  
Soumitra Mukhopadhyay

Introduction: Studies have shown different views regarding the effect of music in vitals e.g Heart rate (HR), Blood pressure (BP) and atiention. The effect of preferred music with lyrics in vitals and reaction time in stroop test has not been performed in Nepalese students so, we conducted the study. Objective: To find out the change in HR, BP and reaction time in Stroop test before and after their preferred music with lyrics. Methodology Thirty male medical and paramedical students aged 25.27 ± 2.0 participated in study. The vital signs and reaction time in Stroop test before and after music was taken. Results Paired-t test was used to compare means before and after exposure to music. The means are expressed as Mean ± SD. Heart rate (HR) increased after exposure to music (66.33±9.51 Vs 67.2±8.44) (p<.05). The error in Stroop test was less after music (.66±.49 Vs.63±.66) (p<.05). The reaction time after error correction decreased post exposure to music (24.117±4.61Vs23.29±4.45) (p<.05). Conclusion The heart rate increased after exposure to music. The errors decreased after listening to music which also decreased reaction time.


2017 ◽  
Vol 28 (3) ◽  
pp. 409-415 ◽  
Author(s):  
Barbara-Jo Achuff ◽  
Jameson C. Achuff ◽  
Hwan H. Park ◽  
Brady Moffett ◽  
Sebastian Acosta ◽  
...  

AbstractIntroductionHaemodynamically unstable patients can experience potentially hazardous changes in vital signs related to the exchange of depleted syringes of epinephrine to full syringes. The purpose was to determine the measured effects of epinephrine syringe exchanges on the magnitude, duration, and frequency of haemodynamic disturbances in the hour after an exchange event (study) relative to the hours before (control).Materials and methodsBeat-to-beat vital signs recorded every 2 seconds from bedside monitors for patients admitted to the paediatric cardiovascular ICU of Texas Children’s Hospital were collected between 1 January, 2013 and 30 June, 2015. Epinephrine syringe exchanges without dose/flow change were obtained from electronic records. Time, magnitude, and duration of changes in systolic blood pressure and heart rate were characterised using Matlab. Significant haemodynamic events were identified and compared with control data.ResultsIn all, 1042 syringe exchange events were found and 850 (81.6%) had uncorrupted data for analysis. A total of 744 (87.5%) exchanges had at least 1 associated haemodynamic perturbation including 2958 systolic blood pressure and 1747 heart-rate changes. Heart-rate perturbations occurred 37% before exchange and 63% after exchange, and 37% of systolic blood pressure perturbations happened before syringe exchange, whereas 63% occurred after syringe exchange with significant differences found in systolic blood pressure frequency (p<0.001), duration (p<0.001), and amplitude (p<0.001) compared with control data.ConclusionsThis novel data collection and signal processing analysis showed a significant increase in frequency, duration, and magnitude of systolic blood pressure perturbations surrounding epinephrine syringe exchange events.


2015 ◽  
Vol 20 (2) ◽  
pp. 112-118 ◽  
Author(s):  
Lauren M. Estkowski ◽  
Jennifer L. Morris ◽  
Elizabeth A. Sinclair

OBJECTIVES: To describe and compare off-label use and cardiovascular (CV) adverse effects of dexmedetomidine in neonates and infants in the pediatric intensive care unit (PICU). METHODS: Patients younger than 12 months with corrected gestational ages of at least 37 weeks who were receiving continuous infusion of dexmedetomidine at a tertiary pediatric referral center between October 2007 and August 2012 were assessed retrospectively. Patients were excluded if dexmedetomidine was used for procedural sedation, postoperative CV surgery, or if postanesthesia infusion weaning orders existed at the time of PICU admission. RESULTS: The median minimum dexmedetomidine dose was similar between infants and neonates at 0.2 mcg/kg/hr (IQR, 0.17–0.3) versus 0.29 mcg/kg/hr (IQR, 0.2–0.31), p = 0.35. The median maximum dose was higher for infants than neonates (0.6 mcg/kg/hr [IQR, 0.4–0.8] vs. 0.4 mcg/kg/hr [IQR, 0.26–0.6], p &lt; 0.01). Additional sedative use was more common in infants than neonates (75/99 [76%] vs. 15/28 [54%], p = 0.02). At least 1 episode of hypotension was noted in 34/127 (27%) patients and was similar between groups. An episode of bradycardia was identified more frequently in infants than neonates (55/99 [56%] vs. 2/28 [7%], p &lt; 0.01). Significant reduction in heart rate and systolic blood pressure was noted when comparing baseline vital signs to lowest heart rate and systolic blood pressure during infusion (p &lt; 0.01). CONCLUSIONS: Dexmedetomidine dose ranges were similar to US Food and Drug Administration–labeled dosages for intensive care unit sedation in adults. More infants than neonates experienced a bradycardia episode, but infants were also more likely to receive higher dosages of dexmedetomidine and additional sedatives.


1986 ◽  
Vol 251 (6) ◽  
pp. H1126-H1133 ◽  
Author(s):  
M. R. Warner ◽  
J. M. Loeb

We examined the integration of heart rate and neural influences at the atrioventricular (AV) node in conscious dogs. Animals were anesthetized and, under sterile conditions, instrumented to chronically record atrial and ventricular electrograms and blood pressure. In the conscious state, electrocardiogram (ECG), respiration, blood pressure, and electrograms were recorded on a beat-by-beat basis, and heart rate and AV interval were plotted graphically as a function of time. Resting animals exhibited both respiratory sinus arrhythmia and marked oscillations in AV conduction time associated with respiration. During inspiration AV interval was shortened, and during expiration AV interval was prolonged. To obviate the effect of cyclic changes in heart rate, atrial pacing was used to increase heart rate over a wide range both abruptly and linearly. Regardless of the pattern of heart rate change, AV interval oscillated at the respiratory frequency at pacing rates 10-100 beats/min above control. Higher levels of atrial pacing resulted in AV conduction patterns that were correlated with changes in blood pressure. Thus in the conscious dog variations in AV conduction time occur on a beat-by-beat basis in conjunction with respiration; oscillatory activity of AV conduction is not dependent on simultaneous changes in heart rate; and during atrial pacing, autonomic neural activity associated with respiration and blood pressure appears to dynamically modulate AV conduction with respiratory effects predominating at low heart rates and blood pressure effects at high heart rates.


Sign in / Sign up

Export Citation Format

Share Document