HPLC ANALYSIS OF TIAPROFENIC ACID IN THE SAMPLES OF WHOLE BLOOD USING L-L AND S-L EXTRACTIONS

2000 ◽  
Vol 23 (20) ◽  
pp. 3191-3201 ◽  
Author(s):  
J. Sochor ◽  
J. Klimeš ◽  
J. Sedláček ◽  
B. Somolíková ◽  
D. Slovenčík
1987 ◽  
Author(s):  
M R Buchanan ◽  
E Bastida ◽  
J Aznar-Salatti ◽  
P de Groot

It is generally thought that the extracellular matrix (ECM) is thrombogenic.However,one of us (MRB) has reported that the ECM is thromboresistant,and postulated that this was due to the release of endothelial cell (EC) 13-hydroxyoctadecadienoic acid (13-HODE) into the ECM. To test this possibility, we measured platelet adhesion (PLT ADH) onto cultured ECs and their ECMs exposed by 3 methods. We also extracted the ECMs for HPLC analysis of 13-HODE.PLT ADH was expressed as i)adhesion of 3H-adenine labelled platelets/mm2 of ECs or ECMs under static conditions, and ii) % surface^ area coverage measured morphometrically following 5"perfusion with citrated whole blood at 1300 sec-1 in the flat chamber.ECMs were prepared by removing the EC monolayers by freeze thawing , cellulose acetate stripping or NH4OH treatment. PLT ADH to ECs under static and flow conditions were 4700±240/mm2 and 0.1%, respectively, and were associated with 12,6± 1 pg of 13-HODE/mm2 of EC surface (M+SEM). Removal of the ECs by freeze thawing or stripping, resulted in a 18% and 25% increase in PLT ADH to the ECM,under static and flow conditions respectively, and a 80% decrease in ECM associated 13-HODE level. Removal of the EC by NH4OH resulted in a 380% and 770% increase in PLT ADH to the ECM in static and flow conditions. 13-HODE was undetectable.These data support the hypothesis that 13-HODE released from ECs influences the ECM thrombogenecity, and indicate that the residual amounts of components present in the ECMs following EC removal is influenced by the method of ECM preparation.


Author(s):  
W. H. Zucker ◽  
R. G. Mason

Platelet adhesion initiates platelet aggregation and is an important component of the hemostatic process. Since the development of a new form of collagen as a topical hemostatic agent is of both basic and clinical interest, an ultrastructural and hematologic study of the interaction of platelets with the microcrystalline collagen preparation was undertaken.In this study, whole blood anticoagulated with EDTA was used in order to inhibit aggregation and permit study of platelet adhesion to collagen as an isolated event. The microcrystalline collagen was prepared from bovine dermal corium; milling was with sharp blades. The preparation consists of partial hydrochloric acid amine collagen salts and retains much of the fibrillar morphology of native collagen.


Author(s):  
E. T. O'Toole ◽  
R. R. Hantgan ◽  
J. C. Lewis

Thrombocytes (TC), the avian equivalent of blood platelets, support hemostasis by aggregating at sites of injury. Studies in our lab suggested that fibrinogen (fib) is a requisite cofactor for TC aggregation but operates by an undefined mechanism. To study the interaction of fib with TC and to identify fib receptors on cells, fib was purified from pigeon plasma, conjugated to colloidal gold and used both to facilitate aggregation and as a receptor probe. Described is the application of computer assisted reconstruction and stereo whole mount microscopy to visualize the 3-D organization of fib receptors at sites of cell contact in TC aggregates and on adherent cells.Pigeon TC were obtained from citrated whole blood by differential centrifugation, washed with Ca++ free Hank's balanced salts containing 0.3% EDTA (pH 6.5) and resuspended in Ca++ free Hank's. Pigeon fib was isolated by precipitation with PEG-1000 and the purity assessed by SDS-PAGE. Fib was conjugated to 25nm colloidal gold by vortexing and the conjugates used as the ligand to identify fib receptors.


1974 ◽  
Vol 134 (1) ◽  
pp. 181b-181
Author(s):  
R. E. Willard
Keyword(s):  

2018 ◽  
Vol 88 (3-4) ◽  
pp. 151-157 ◽  
Author(s):  
Scott W. Leonard ◽  
Gerd Bobe ◽  
Maret G. Traber

Abstract. To determine optimal conditions for blood collection during clinical trials, where sample handling logistics might preclude prompt separation of erythrocytes from plasma, healthy subjects (n=8, 6 M/2F) were recruited and non-fasting blood samples were collected into tubes containing different anticoagulants (ethylenediaminetetra-acetic acid (EDTA), Li-heparin or Na-heparin). We hypothesized that heparin, but not EDTA, would effectively protect plasma tocopherols, ascorbic acid, and vitamin E catabolites (α- and γ-CEHC) from oxidative damage. To test this hypothesis, one set of tubes was processed immediately and plasma samples were stored at −80°C, while the other set was stored at 4°C and processed the following morning (~30 hours) and analyzed, or the samples were analyzed after 6 months of storage. Plasma ascorbic acid, as measured using HPLC with electrochemical detection (LC-ECD) decreased by 75% with overnight storage using EDTA as an anticoagulant, but was unchanged when heparin was used. Neither time prior to processing, nor anticoagulant, had any significant effects upon plasma α- or γ-tocopherols or α- or γ-CEHC concentrations. α- and γ-tocopherol concentrations remained unchanged after 6 months of storage at −80°C, when measured using either LC-ECD or LC/mass spectrometry. Thus, refrigeration of whole blood at 4°C overnight does not change plasma α- or γ-tocopherol concentrations or their catabolites. Ascorbic acid is unstable in whole blood when EDTA is used as an anticoagulant, but when whole blood is collected with heparin, it can be stored overnight and subsequently processed.


Sign in / Sign up

Export Citation Format

Share Document