scholarly journals Spatial analysis of coliform bacteria contained in phreatic water in colomadu sub-district karanganyar

2021 ◽  
Vol 683 (1) ◽  
pp. 012001
Author(s):  
I Wisnu ◽  
C Muryani dan Ahmad
2020 ◽  
Vol 2 (2) ◽  
Author(s):  
Wanda Aulya ◽  
Fadhliani Fadhliani ◽  
Vivi Mardina

Water is the main source for life and also the most severe substance caused by pollution. The mandatory parameters for determining microbiological quality of drinking water are total non-fecal Coliform bacteria and Coliform fecal (Escherichia coli). Coliform bacteria are a group of microorganisms commonly used as indicators, where these bacteria can be a signal to determine whether a water source has been contaminated by bacteria or not, while fecal Coliform bacteria are indicator bacteria polluting pathogenic bacteria originating from human feces and warm-blooded animals (mammals) . The water inspection method in this study uses the MPN (Most Probable Number) method which consists of 3 tests, namely, the presumption test, the affirmation test, and the reinforcement test. The results showed that of 15 drinking water samples 8 samples were tested positive for Coliform bacteria with the highest total bacterial value of sample number 1, 15 (210/100 ml), while 7 other samples were negative. From 8 positive Coliform samples only 1 sample was stated to be negative fecal Coliform bacteria and 7 other samples were positive for Coliform fecal bacteria with the highest total bacterial value of sample number 1 (210/100 ml).


2019 ◽  
Vol 7 (2) ◽  
pp. 115
Author(s):  
Dini Yuliansari

The well is one of the source water used for bathing, washing, and drinking by the citizens in Jiken Hamlet, Rarang Village, Terara Sub-District. Poor dug well construction conditions can affect the amount of coliform bacteria contained in the dug well water. The purpose of this study is to identify the construction of dug wells and the content of coliform bacteria in dug well water and determine the relationship between dug well construction and the content of coliform bacteria. This research is analytic with a cross sectional study design. The results were obtained from 11 samples of dug wells which were observed in construction and the coliform content was known that all samples did not requirements as good dug well construction. Coliform content test results showed that as many as 5 dug well water samples did not pass the clean water quality standards. The results of data analysis with the chi-square test variable construction of dug wells with coliform content variable  showed 0,172 > 0,05, then the concluded is the dug well not suitable to use by people in that area as a source of water for daily needs.


2018 ◽  
Author(s):  
Ion Anghel ◽  
Gunther Maier ◽  
Costin Ciora ◽  
Vlad-Andrei Porumb

2016 ◽  
Vol 10 (1) ◽  
pp. 13-23 ◽  
Author(s):  
Agustina Arianita Cahyaningtyas ◽  
Wiwik Pudjiastuti ◽  
Ilham Ramdhan

One attempt to reduce the number of pathogenic microbes in milk is through the pasteurization process. This research aims to determine the effect of storage temperature on the organoleptic, acidity (pH) and growth of coliform bacteria in pasteurized milk. Pasteurized milk is stored at the varies of temperature  4°C (observed for 14 days), 10°C-15°C (observed for 14 days) and 25°C-27°C (observed for 22 hours), as well as also conducted an initial analysis pasteurized milk. The parameters were observed among other organoleptic (smell, taste, color, texture), pH and total coliform bacteria. Testing acidity using pH paper, while the growth of coliform bacteria testing done using Total Plate Count method based on ISO 2897 in 2008. The results of this study indicate that storage at 4°C for 14 days, organoleptic pasteurized milk is still good until the day ke- 8, pH progressively decreases, and the growth of coliform bacteria obtained the highest score of 3100x101 CFU / ml. Storage at 10°C-15°C for 14 days, organoleptic pasteurized milk is still good until the 6th day, the pH progressively decreases, and the growth of coliform bacteria obtained the highest score of 5729x101 CFU / ml. Storage at 25°C-27°C for 22 days, organoleptic pasteurized milk is still good until the 9th, pH progressively decreases, and the growth of coliform bacteria obtained the highest score of 4.3 x106 CFU / ml.ABSTRAKSalah satu usaha untuk mengurangi jumlah mikroba patogen pada susu adalah melalui proses pasteurisasi. Penelitian ini bertujuan untuk mengetahui pengaruh suhu penyimpanan terhadap organoleptik, derajat keasaman (pH) dan pertumbuhan bakteri Coliform pada susu pasteurisasi. Susu pasteurisasi disimpan pada suhu yang bervariasi yaitu suhu 4°C (diamati selama 14 hari), suhu 10°C-15°C (diamati selama 14 hari) dan suhu 25°C-27°C (diamati selama 22 jam), serta dilakukan pula analisa awal susu pasteurisasi. Parameter yang diamati antara lain organoleptik (bau, rasa, warna, tekstur), pH dan jumlah bakteri Coliform. Pengujian derajat keasaman menggunakan kertas pH, sedangkan pengujian pertumbuhan bakteri Coliform dilakukan dengan menggunakan metode Total Plate Count berdasarkan SNI 2897 Tahun 2008. Hasil penelitian ini menunjukkan bahwa penyimpanan pada suhu 4°C selama 14 hari, organoleptik susu pasteurisasi masih baik sampai dengan hari ke-8, pH semakin lama semakin menurun, dan pertumbuhan bakteri Coliform didapatkan nilai tertinggi sebesar 3100x101 Cfu/ml. Penyimpanan pada suhu 10°C-15°C selama 14 hari, organoleptik susu pasteurisasi masih baik sampai hari ke-6, pH semakin lama semakin menurun, dan pertumbuhan bakteri Coliform didapatkan nilai tertinggi sebesar 5729x101 Cfu/ml. Penyimpanan pada suhu 25°C-27°C selama 22 hari, organoleptik susu pasteurisasi masih baik sampai jam ke-9, pH semakin lama semakin menurun, dan pertumbuhan bakteri Coliform didapatkan nilai tertinggi sebesar 4,3 x106 Cfu/ml.Kata kunci : bakteri coliform, derajat keasaman, suhu penyimpanan, organoleptik, susu pasteurisasi


Sign in / Sign up

Export Citation Format

Share Document