scholarly journals Saline water desalination using solar energy: performance analysis and implementation barriers

2021 ◽  
Vol 894 (1) ◽  
pp. 012020
Author(s):  
R A Kusumadewi ◽  
Y Wijayanti ◽  
M Fittkow

Abstract Solar water desalination system is one of the alternatives for supplying fresh water. On the other hand, some people are reluctant to use and rely on water produced by the system. Also, there are other barriers to the adoption of this system in Indonesia. This research aimed to conduct a preliminary study on the performance of solar desalination systems and identify factors that hindered its implementation. The methodology applied in this study consist of two approaches. First, the desalination system performance is determined by the quantity of freshwater produced and the quality of feed water, distilled water, and brine compared to Indonesia’s water quality standard. Second, the identification of implementation barriers was evaluated in the structural analysis method using MICMAC (the Impact Matrix Cross-Reference Multiplication Applied to a Classification) software. The performance analysis result shows low efficiency based on desalinated water produced, which ranges from 2.59% up to 9.67%. The water quality parameters of pH, turbidity, TDS, chloride, Fe, and hardness met the Indonesian water quality standard. The factor of “uncertainty of subsidies,” “niche market,” “poor solar energy data,” and “lack of policy/regulatory framework” were determined as critical barriers which have the most significant influence and highest independence.

Author(s):  
Riana Ayu Kusumadewi ◽  
Suprihanto Notodarmodjo ◽  
Qomarudin Helmy

The continues deficiency of consumable water is a significant issue in developing countries, and contaminated water can result in various diseases, which are often lethal. Solar desalination seems to be a promising method and alternative way for supplying fresh water. <strong>Aim:</strong> The aim of this research is to study heat transfer in desalination system and the quality of feed water, distilled water and brine compared to the quality standard. Feed water consists of salinity 12‰ and 38‰ salinity. <strong>Methodology and Result:</strong> At first, initial characterization of feed water was conducted, then temperature on fourteen points was measured using thermocouples and thermometer so heat transfer rate can be calculated. After that, the final characterization of water production was conducted. From the  observation, it was found that evaporative heat transfer for vacuum pressure of -0.05, -0.1, -0.15, -0.2, -0.25, and -0.3 bar respectively were 173.77, 180.07, 190.79, 481.66, 242.57, and 246.24 W/m2. The result of water quality test of distilled water produced from saline water desalination for some parameters respectively were pH 7.4; turbidity 2.73 NTU; TDS 27.45 mg/L; chloride 84.98 mg/L; Fe 2.13 mg/L; total hardness 0.1698 mg/L; and <em>Escherichia coli</em> 12 cell/mL . <strong>Conclusion, significance and impact study:</strong> It can be concluded that distilled water produced by desalination system was met drinking water quality standard according to Minister of Health Regulation No. 492 of 2010.


2014 ◽  
Vol 971-973 ◽  
pp. 2088-2091
Author(s):  
Yan Xia Liu

The submerged membrane bioreactor (MBR) was used to treat schoolyard domestic sewage. The impact of DO、pH and HRT to the removal effect of COD and NH3-N were studied. The results show that when DO=2.5 mg/L, pH=6.5~8.0, HRT=8 h, the removal effect of COD and NH3-N is above 96% and 88%, which can meet the China Water Quality Standard for Urban Miscellaneous Water Consumption (GB/T 18920-2002).


2011 ◽  
Vol 374-377 ◽  
pp. 1021-1024
Author(s):  
Xian Qiu Zhang ◽  
Jing Feng Xu ◽  
Ming Xia Du ◽  
Yong Zhang

A boiler-water treatment device main composed of solar energy heater and reverse osmosis was designed Experiments on permeation flow and water quality as functions of temperature caused by solar energy were conducted. The experimental results showed that when the operation pressure was kept at 0.9MPa, permeation flow could increase 35.5%, from 6.5L/min to 8.8L/min if the feed water temperature increased from 18°C to 38°C by solar energy; and the produced water could totally meet Chinese water quality standard for middle or low pressure steam-boiler. On the other hand, if the permeation flow was kept at 8 L/min, the operation pressure would drop by 32.2%, from 1.18MPa to 0.78MPa. Based on these experimental results, economic and environmental analysis on a case of 10m3/h boiler-water treatment device by reverse osmosis employing solar energy were conducted, the results shows great significance for energy saving and environmental pollutants cut. All this showed this new RO system with pre-heating the feed water by solar energy could be widely applied in boiler-water treatment.


2017 ◽  
Vol 14 (3) ◽  
pp. 251
Author(s):  
Rita Yulianti ◽  
Emi Sukiyah ◽  
Nana Sulaksana

Daerah penelitian terletak di desa Muaro Limun, Kecamatan Limun Kabupaten Sarolangun Provinsi Jambi. Sungai limun, salah satu sungai besar di daerah kabupaten sarolangun yang dimanfaatkan oleh mayarakat sekitarnya sebagai sumber penghidupan. Penelitian bertujuan untuk mengetahui pengaruh kegiatan penambangan terhadap kualitas air sungai Batang Limun, dan perubahan sifat fisik dan  kimia yang diakibatkan   kegiatan penambangan.Metode yang digunakan adalah  metode grab sampel, serta stream sedimen untuk dianalis di laboratorium. Sejumlah sampel diambil di beberapa lokasi Penambangan Emas berdasarkan Aliran Sub-DAS dan dibandingkan dengan beberapa sampel lain yang diambil pada lokasi yang belum terkontaminasi oleh kegiatan penambangan. Analisis kualitas air mengacu pada  SMEWWke 22 tahun 2012 dan standar baku mutu air kelas II dalam PP No 82 yang dikeluarkan oleh Menteri Kesehatan No. 492/Menkes/Per/IV/2010. Diketahui sungai Batang Limun telah mengalami perubahan karakteristik fisika dan kimia. Dari grafik  kosentrasi kekeruhan, pH, TSS, TDS  Cu, Pb, Zn, Mn, Hg terlihat bahwa penambang emas tanpa izin (PETI) dengan cara amalgamasi yang menyebabkan terjadinya penurunan kualitas air sungai. Sejak tahun 2009 sampai tahun 2015  sungai Limun dan sekitarnya terus mengalami penurunan kualitas air. Penurunan kualitas yang cukup tinggi terjadi  yaitu peningkatan nilai Rata-rata konsentrasi merkuri pada sungai Batang Limun dari 0,18ppb (0,00018 mg/l)  menjadi 0,3ppb (0,0003 mg/l), peningkatan tersebut dipengaruhi oleh proses kegiatan penambangan dan nilai tersebut masih dibawah standar baku mutu air kelas II  pp nomor 82 tahun 2010.Kata kunci :   Kualitas Air, Sungai Limun,TSS, Merkuri, PETI Limun river is one of the major rivers in the area of Sarolangun, which utilized by the society as a source of livelihood. The aim of study  to analyze the effect of mining activities on  the water quality of Batang Limun River, and the changes of physical and chemical properties of water. The method used are grab  and stream samples to  sediment analyzed in the laboratory. A number of samples were taken at several locations based Flow Gold Mining Sub-watershed and compared to some other samples taken at the location that has not been contaminated by mining activities. Water quality analysis referring to SMEWW, 22nd edition 2012 and refers to Regulation No 82 that issued by Minister of Health No. 492 / Menkes / Per / IV / 2010.The results showed that the Limun river has undergone chemical changes in physical characteristics. These symptoms can be seen from the discoloration of clear water in the river before the mine becomes brownish after mining, based on graphic of muddiness concentration: pH, TSS, TDS Cu, Pb, Zn, Mn, Hg have seen that  the illegal miner which used amalgamation caused deterioration in water quality, data from 2009 to 2015 Limun river and surrounding areas continue to experience a decrease in water quality. The decreasing of water quality showed in the TSS parameter which found in the area is to high based on  the standard of water quality class II pp number 82 of 2010. An increase in the value of average concentrations of mercury in the Batang Limun river before mine 0,18ppb (0.00018 mg / l) into 0,3ppb (0.0003 mg / l) on the river after the mine. The increase was affected by the mining activities and the value is still below the air quality standard Grade II pp numbers 82 years 2010, although the value is still below with the standards quality standard, the mercury levels in water should still be a major concern because if it accumulates continuously in the water levels will increase and will be bad for health. In contrast to the concentration of mercury in sediments that have a higher value is 153 ppb (0,513ppm ) .Key Words :   Water Quality, Limun River, Mercury, Illegal gold mining


2016 ◽  
Vol 16 (1) ◽  
pp. 19
Author(s):  
Gorby Corneles Tarima ◽  
Jemmy Abidjulu ◽  
Harry S.J. Koleangan

ANALISIS KUALITAS AIR SUNGAI SARIO KECAMATAN SARIO MANADO  SULAWESI UTARAABSTRAK Penelitian ini dilakukan untuk menganalisis kualitas air sungai Sario berdasarkan sifat fisika dan kimia sesuai dengan PP No 82 Tahun 2001. Penelitian dilakukan di laboratorium Baristand Industri Manado pada bulan November 2015, dengan 4 sampel air yang diambil pada 4 titik dari hulu sampai hilir sungai Sario Kota Manado menggunakan 7 parameter yaitu kekeruhan, pH, nitat, nitrit, BOD, COD dan DO. Hasil penelitian ini menunjukkan bahwa kualitas air sungai Sario yang sesuai dengan ambang baku mutu air berdasarkan PP No. 82 Tahun 2001 hanyalah pada bagian hulu sampai tengah Sungai sebelum memasuki wilayah Kota Manado, sedangkan pada sekitaran hilir sungai Sario telah tercemar yang berhubungan dengan aktivitas masyarakat dengan diindikasikan berdasarkan konsentrasi BOD, COD dan DO yang buruk dan tidak sesuai dengan ambang baku mutu air berdasarkan PP No. 82/2001. Kata kunci : Kualitas Air, Sungai Sario   ANALYSIS OF RIVER WATER QUALITY SARIO DISTRICT MANADO  NORTH SULAWESI ABSTRACT This study was conducted to analyze the Sario river water quality based on physical and chemical properties in accordance with PP No. 82 of 2001. The study was conducted in laboratory Baristand Industry Manado in November 2015, with four water samples taken at 4 points from upstream to downstream Sario City Manado using 7 parameters: turbidity, pH, nitat, nitrite, BOD, COD and DO.  The results of this study indicate that the water quality in accordance with the Sario river water quality standard threshold under PP No. 82 of 2001 only on the upstream side to the middle of the river before entering the city of Manado, whereas the downstream Area Sario river has been polluted related community activities to be indicated by the concentration of BOD, COD and DO poor and not in accordance with the water quality standard threshold based PP No. 82 of 2001. Keywords: Water Quality, River Sario


Author(s):  
Sayyid Arrasyid ◽  
Zahidah Hasan ◽  
Izza Mahdiana Apriliani ◽  
Heti Herawati

Cirata Reservoir is one of the three cascade reservoirs fed by the Citarum Watershed with an area of ​​62 km2 (6.200 ha) and has a water volume of 1.900 million m3. The great potential of the waters in the Cirata Reservoir is utilized by the local community as a source of livelihood, namely by conducting aquaculture activities using floating net cages (FNC) in excess. FNC is thought to be a source of waste that reduces reservoir water quality. This research aims to determine the impact of FNC cultivation on primary productivity with different FNC densities at each station. The research was conducted in Cianjur Regency by taking on three stations, namely in the areas of Jangari, Maleber, and Patok Beusi on November 6 - December 8, 2019. The method used in the research was purposive sampling then analyzed in detail and quantitatively. The results show that reservoir waters have an average of physical parameters, namely temperature 32.2-32.6oC, transparency 0.59-0.68 meters, pH 7.1-7.3, carbon dioxide 15.4-16.1 mg / l, Dissolved Oxygen 6.9-7.3 mg / l, Biochemical Oxygen Demand 6.1-7.8 mg / l, nitrate 0.208-0.222 mg / l, ammonia 0.002833-0.003056 mg / l, phosphate 0,165-0,167 mg / l and primary productivity 240,36-277,90 mgC/m3/hour. This shows that the water indicator is still classified as good because it does not exceed the water quality standard.


Author(s):  
Desy Rosarina ◽  
Ellysa Kusuma Laksanawati ◽  
Dewi Rosanti

This paper explained heavy metals and chemical properties from the Cisadane River in Tangerang City. A survey method was used to determine the place for sampling the test material. Water measurement is carried out in situ and laboratory tests. Data retrieval was done by purposive sampling determining three observation stations, namely in the Taman Gajah Tunggal park area (station1), Babakan Cikokol residential area (station 2), and Karawaci paper mill area (station 3). The analysis was carried out exactly using analysis. Namely, analysis carried out in the laboratory. The parameters observed were COD, phosphate, DO, BOD, pH. Results of this study informed the water quality in the Cisadane City river did not meet Class II Water Quality Standards based on Government Regulation Number 82, the year 2001. The COD content only meets class II water quality standards at stations 1 and 3. BOD and phosphate content is high and exceeds class II water quality standards. Heavy metal content still meets the water quality standard threshold with a value of Cd less than 0.01 mg/L, Cu less than 0.02 mg/L, Pb less than 0.03mg/L, and Cr less than 0.05mg/L. Zn content exceeds the water quality standard threshold at station three and meets water quality standards at stations 1 and 2 with a value of less than 0.05mg/L.


2021 ◽  
Author(s):  
Pierre Pedenaud ◽  
Marianna Rondon ◽  
Nicolas Lesage ◽  
Eric Tournis ◽  
Riccardo Giolo ◽  
...  

Abstract A new seawater laboratory pilot has been installed in order to evaluate the impact of the seawater quality on the performance of nanofiltration membranes and filters. The test program implemented was designed to produce the data required to optimize the design and operating parameters of a subsea sulfate removal plant, particularly with respect to the technology developed by Total, Saipem and Veolia, co-owners of the development. The equipment qualification plan is approaching completion with the development of subsea barrier-fluidless pumps, all-electric control systems, high-cycling valves operated by electric actuators and subsea water analyzers. This presented pilot laboratory study completes this plan. Nanofiltration membranes are commonly used to remove the sulfates found in seawater before the water is injected into wells. The principal advantages of relocating this equipment from topside to subsea are better reservoir sweep control, a substantial subsea water injection network reduction and savings on space and weight on the topsides deck. The move to subsea offers the opportunity to simplify the process due to improved deep water quality. This was previously demonstrated through a subsea test campaign. This new pilot study provides data both on the performance of a plant operating with different feed water quality and on the success of operating changes to further optimize the plant performance. The pilot has been installed at the Palavas-les-Flots site in France. Raw water collected from the basin was mixed with ultra-filtered water in order to calibrate the feed water quality. The pilot includes a two stage nanofiltration configuration and single stage nanofiltration unit. The two stage configuration was used to produce data for operation across an array of feed water quality and plant operating conditions. The single stage unit was used to produce data on membrane fouling over a long operating duration. Results from these tests and discussion on how this data relates to subsea plant performance shall be presented. This innovative approach enables a wide range of subsea water quality to be simulated and tested against different process configurations of the subsea unit. Indeed, for each industrial subsea application, the raw seawater quality is dependent on both the region and the depth of the seawater inlet. With this experimental data acquisition campaign and understanding of the seawater quality at inlet, the system design can be tailor-made for each future application case.