Association Between Heart Rate Variability Measures and Blood Glucose Levels: Implications for Noninvasive Glucose Monitoring for Diabetes

2016 ◽  
Vol 18 (6) ◽  
pp. 366-376 ◽  
Author(s):  
Leon J. Rothberg ◽  
Ty Lees ◽  
Roderick Clifton-Bligh ◽  
Sara Lal
Sensors ◽  
2021 ◽  
Vol 21 (20) ◽  
pp. 6820
Author(s):  
Bushra Alsunaidi ◽  
Murad Althobaiti ◽  
Mahbubunnabi Tamal ◽  
Waleed Albaker ◽  
Ibraheem Al-Naib

The prevalence of diabetes is increasing globally. More than 690 million cases of diabetes are expected worldwide by 2045. Continuous blood glucose monitoring is essential to control the disease and avoid long-term complications. Diabetics suffer on a daily basis with the traditional glucose monitors currently in use, which are invasive, painful, and cost-intensive. Therefore, the demand for non-invasive, painless, economical, and reliable approaches to monitor glucose levels is increasing. Since the last decades, many glucose sensing technologies have been developed. Researchers and scientists have been working on the enhancement of these technologies to achieve better results. This paper provides an updated review of some of the pioneering non-invasive optical techniques for monitoring blood glucose levels that have been proposed in the last six years, including a summary of state-of-the-art error analysis and validation techniques.


Author(s):  
E.Yu. Pyankova ◽  
◽  
L.A. Anshakova ◽  
I.A. Pyankov ◽  
S.V. Yegorova ◽  
...  

The problems of complications of diabetes mellitus cannot be solved without constant monitoring of blood glucose levels. The evolution of additional technologies for the determination of glucose in the blood of the last decades makes it possible to more accurately predict the risks of complications, both in the individual and in the patient population as a whole. The article provides an overview of the methods used in modern diabetology, facilitating control over the variability of blood glucose levels and helping in a more accurate selection of glucose-lowering therapy. All presented methods are currently working in real clinical practice in the Khabarovsk Krai


Author(s):  
Khaled Eskaf ◽  
Tim Ritchings ◽  
Osama Bedawy

Diabetes mellitus is one of the most common chronic diseases. The number of cases of diabetes in the world is likely to increase more than two fold in the next 30 years: from 115 million in 2000 to 284 million in 2030. This chapter is concerned with helping diabetic patients to manage themselves by developing a computer system that predicts their Blood Glucose Level (BGL) after 30 minutes on the basis of their current levels, so that they can administer insulin. This will enable the diabetic patient to continue living a normal daily life, as much as is possible. The prediction of BGLs based on the current levels BGLs become feasible through the advent of Continuous Glucose Monitoring (CGM) systems, which are able to sample patients' BGLs, typically 5 minutes, and computer systems that can process and analyse these samples. The approach taken in this chapter uses machine-learning techniques, specifically Genetic Algorithms (GA), to learn BGL patterns over an hour and the resulting value 30 minutes later, without questioning the patients about their food intake and activities. The GAs were invested using the raw BGLs as input and metadata derived from a Diabetic Dynamic Model of BGLs supplemented by the changes in patients' BGLs over the previous hour. The results obtained in a preliminary study including 4 virtual patients taken from the AIDA diabetes simulation software and 3 volunteers using the DexCom SEVEN system, show that the metadata approach gives more accurate predictions. Online learning, whereby new BGL patterns were incorporated into the prediction system as they were encountered, improved the results further.


Author(s):  
C P Williams ◽  
G K Davies ◽  
D F Child

Improvement in the control of diabetic patients is aided by a knowledge of blood glucose levels during a ‘normal’ (non-hospitalised) day. We have devised a 5 μl capillary tube collection system as a ‘kit’ for home use by diabetics. Blood collected into 5 μl capillary tubes is washed into a protein precipitant by the patient. The completed kit is posted to the laboratory for analysis. The technique has achieved a high degree of patient acceptability. Subsequent analysis involves the addition of a single reagent. Reagents, patient samples, and standards are stable, and the precision of the technique compares favourably with our routine glucose procedure.


Biostatistics ◽  
2020 ◽  
Author(s):  
Irina Gaynanova ◽  
Naresh Punjabi ◽  
Ciprian Crainiceanu

Summary We introduce a multilevel functional Beta model to quantify the blood glucose levels measured by continuous glucose monitors for multiple days in study participants with type 2 diabetes mellitus. The model estimates the subject-specific marginal quantiles, quantifies the within- and between-subject variability, and produces interpretable parameters of blood glucose dynamics as a function of time from the actigraphy-estimated sleep onset. Results are validated via simulations and by studying the association between the estimated model parameters and hemoglobin A1c, the gold standard for assessing glucose control in diabetes.


2016 ◽  
Vol 19 (5) ◽  
pp. 397-405 ◽  
Author(s):  
Alina Yur'evna Babenko ◽  
Yulia Alexeevna Kononova ◽  
Alexandr Ivanovich Tsiberkin ◽  
Michail Konstantinovich Khodzitsky ◽  
Elena Nilkolaevna Grineva

Improved prognoses of patients with type 2 diabetes are primarily determined by the extent of blood glucose control (correction of both hyper- and hypoglycemia and normalization of blood glucose levels). The proper identification and timely correction of abnormal blood glucose levels require frequent blood glucose monitoring by the patient. Currently used methods for the self-monitoring of blood glucose have significant drawbacks that limit their use. The most significant problems with these methods include insufficient accuracy, invasiveness and high cost, leading to noncompliance and difficult assessment of disease status. Such factors underscore the need for a noninvasive, cost-effective and highly accurate method to measure blood glucose levels. There are several different approaches for the noninvasive measurement of blood glucose levels, including optical analysis, ultrasound and bioimpedance. The concept of a noninvasive glucometer was launched more than 30 years ago. Nevertheless, most noninvasive technologies are still in early stages of development and are not used in clinical practice. This review describers the most promising developments in this area.


2021 ◽  
Vol 13 (1) ◽  
Author(s):  
Jen-Hung Huang ◽  
Yung-Kuo Lin ◽  
Ting-Wei Lee ◽  
Han-Wen Liu ◽  
Yu-Mei Chien ◽  
...  

Abstract Background Glucose monitoring is vital for glycemic control in patients with diabetes mellitus (DM). Continuous glucose monitoring (CGM) measures whole-day glucose levels. Hemoglobin A1c (HbA1c) is a vital outcome predictor in patients with DM. Methods This study investigated the relationship between HbA1c and CGM, which remained unclear hitherto. Data of patients with DM (n = 91) who received CGM and HbA1c testing (1–3 months before and after CGM) were retrospectively analyzed. Diurnal and nocturnal glucose, highest CGM data (10%, 25%, and 50%), mean amplitude of glycemic excursions (MAGE), percent coefficient of variation (%CV), and continuous overlapping net glycemic action were compared with HbA1c values before and after CGM. Results The CGM results were significantly correlated with HbA1c values measured 1 (r = 0.69) and 2 (r = 0.39) months after CGM and 1 month (r = 0.35) before CGM. However, glucose levels recorded in CGM did not correlate with the HbA1c values 3 months after and 2–3 months before CGM. MAGE and %CV were strongly correlated with HbA1c values 1 and 2 months after CGM, respectively. Diurnal blood glucose levels were significantly correlated with HbA1c values 1–2 months before and 1 month after CGM. The nocturnal blood glucose levels were significantly correlated with HbA1c values 1–3 months before and 1–2 months after CGM. Conclusions CGM can predict HbA1c values within 1 month after CGM in patients with DM.


2021 ◽  
Author(s):  
Matthes Kenning ◽  
Anselm Puchert ◽  
Eckhard Salzsieder

BACKGROUND Maintaining normal blood glucose levels in diabetes therapy is fundamentally linked to precise and accurate blood glucose measurements. In the light of interfering quantities like various substances or hematocrit, these aspects are of utmost clinical importance within a standardized validation of blood glucose monitors for personal use as well as a continuous quality assessment. OBJECTIVE Continuous and independent quality assurance of aspects affecting a blood glucose monitoring system’s performance. METHODS The influence of the hematocrit on the performance of three blood glucose monitors was assessed in accordance with ISO 15197 and sponsor’s requirements. RESULTS Only one device showed acceptable deviations of ≤ 10 mg/dL / 10 % to the reference device across the entire range. The other devices showed minor to clinically relevant interferences, particularly in response to higher hematocrit values. CONCLUSIONS Suitable BGM systems should be selected carefully by health care professionals and patients, especially with medical conditions known to interfere with blood glucose measurements.


2012 ◽  
Vol 08 (01) ◽  
pp. 22 ◽  
Author(s):  
M Susan Walker ◽  
Stephanie J Fonda ◽  
Sara Salkind ◽  
Robert A Vigersky ◽  
◽  
...  

Previous research has shown that realtime continuous glucose monitoring (RT-CGM) is a useful clinical and lifestyle aid for people with type 1 diabetes. However, its usefulness and efficacy for people with type 2 diabetes is less known and potentially controversial, given the continuing controversy over the efficacy of self-monitoring of blood glucose (SMBG) in this cohort. This article reviews theextantliterature on RT-CGM for people with type 2 diabetes, and enumerates several of the advantages and disadvantages of this technology from the perspective of providers and patients. Even patients with type 2 diabetes who are not using insulin and/or are relatively well controlled on oral medications have been shown to spend a significant amount of time each day in hyperglycemia. Additional tools beyond SMBG are necessary to enable providers and patients to clearly grasp and manage the frequency and amplitude of glucose excursions in people with type 2 diabetes who are not on insulin. While SMBG is useful for measuring blood glucose levels, patients do not regularly check and SMBG does not enable many to adequately manage blood glucose levels or capture marked and sustained hyperglycemic excursions. RT-CGM systems, valuable diabetes management tools for people with type 1 diabetes or insulin-treated type 2 diabetes, have recently been used in type 2 diabetes patients. Theextantstudies, although few, have demonstrated that the use of RT-CGM has empowered people with type 2 diabetes to improve their glycemic control by making and sustaining healthy lifestyle choices.


2019 ◽  
Vol 14 (2) ◽  
pp. 130-132 ◽  
Author(s):  
Nicole D. White ◽  
Emily Knezevich

Individuals with diabetes play a significant role in the control of their condition by participating in their own care. Self-monitoring of blood glucose is of particular importance in maintaining adequate glycemic control but when obtained using traditional fingerstick methods, is often limited with by cost, fear of needles or pain and inconvenience. Flash glucose monitoring is an innovative technology available to address these barriers and help people with diabetes better manage their blood glucose levels. Data demonstrating increased frequency in glucose monitoring, patient perspectives related to self-care behaviors, and implications for practice and future research are described.