scholarly journals Effects of antiplatelet components of tomato extract on platelet function in vitro and ex vivo: a time-course cannulation study in healthy humans

2006 ◽  
Vol 84 (3) ◽  
pp. 570-579 ◽  
Author(s):  
Niamh O’Kennedy ◽  
Lynn Crosbie ◽  
Machteld van Lieshout ◽  
John I Broom ◽  
David J Webb ◽  
...  
Cells ◽  
2021 ◽  
Vol 10 (4) ◽  
pp. 730
Author(s):  
Biji Mathew ◽  
Leianne A. Torres ◽  
Lorea Gamboa Gamboa Acha ◽  
Sophie Tran ◽  
Alice Liu ◽  
...  

Cell replacement therapy using mesenchymal (MSC) and other stem cells has been evaluated for diabetic retinopathy and glaucoma. This approach has significant limitations, including few cells integrated, aberrant growth, and surgical complications. Mesenchymal Stem Cell Exosomes/Extracellular Vesicles (MSC EVs), which include exosomes and microvesicles, are an emerging alternative, promoting immunomodulation, repair, and regeneration by mediating MSC’s paracrine effects. For the clinical translation of EV therapy, it is important to determine the cellular destination and time course of EV uptake in the retina following administration. Here, we tested the cellular fate of EVs using in vivo rat retinas, ex vivo retinal explant, and primary retinal cells. Intravitreally administered fluorescent EVs were rapidly cleared from the vitreous. Retinal ganglion cells (RGCs) had maximal EV fluorescence at 14 days post administration, and microglia at 7 days. Both in vivo and in the explant model, most EVs were no deeper than the inner nuclear layer. Retinal astrocytes, microglia, and mixed neurons in vitro endocytosed EVs in a dose-dependent manner. Thus, our results indicate that intravitreal EVs are suited for the treatment of retinal diseases affecting the inner retina. Modification of the EV surface should be considered for maintaining EVs in the vitreous for prolonged delivery.


Coatings ◽  
2021 ◽  
Vol 11 (2) ◽  
pp. 146
Author(s):  
Antonio Celentano ◽  
Tami Yap ◽  
Giuseppe Pantaleo ◽  
Rita Paolini ◽  
Michael McCullough ◽  
...  

Rigenera® is a novel class-1 medical device that produces micro-grafts enriched of progenitors cells without ex vivo manipulation of donor tissues. The manufacturer’s protocol has been supported for a wide variety of clinical uses in the field of regenerative medicine. This study aimed to evaluate its potential use for in vitro cell models. Human primary oral fibroblasts were cultured under standard conditions and processed through Rigenera® over a time course of up to 5 min. Cell viability was assessed using a Trypan Blue exclusion test. It is possible to process fibroblasts through Rigenera® although an initial reduction of cell viability was observed. Additionally, debris was evident in the cell suspension of the processed samples. Scanning electron microscopy (SEM) microanalysis of the debris and electron energy-loss spectroscopy confirmed the presence of metal wear possibly due to the processing conditions used in this study. Interestingly, pore sizes within Rigeneracons® grids were found to range between 250–400 μm. This is the first report assessing the suitability of Rigenera® and Rigeneracons® for in vitro applications. Whilst Rigenera® workflow was found to be amenable to laboratory uses, our results strongly suggest that further research and development is necessary to support the utilization of this technology for enrichment of micro-graft derived cells and cell sorting in vitro.


1989 ◽  
Vol 53 (6) ◽  
pp. 603-613 ◽  
Author(s):  
Bruce Lages ◽  
Harvey J. Weiss

2014 ◽  
Vol 112 (08) ◽  
pp. 412-418 ◽  
Author(s):  
Nima Vaezzadeh ◽  
Ran Ni ◽  
Paul Y. Kim ◽  
Jeffrey I. Weitz ◽  
Peter L. Gross

SummaryHaemostatic impairments are studied in vivo using one of several murine bleeding models. However it is not known whether these models are equally appropriate for assessing coagulation or platelet function defects. It was our study objective to assess the performance of arterial, venous and combined arterial and venous murine bleeding models towards impaired coagulation or platelet function. Unfractionated heparin (UFH) or αIIbβ3 inhibitory antibody (Leo.H4) were administered to mice, and their effects on bleeding in saphenous vein, artery, and tail tip transection models were quantified and correlated with their effects on plasma clotting and ADP-induced platelet aggregation, respectively. All models exhibited similar sensitivity with UFH (EC50 dose = 0.19, 0.13 and 0.07 U/g, respectively) (95% CI = 0.14 – 0.27, 0.08 – 0.20, and 0.03 – 0.16 U/g, respectively). Maximal inhibition of ex vivo plasma clotting could be achieved with UFH doses as low as 0.03 U/g. In contrast, the saphenous vein bleeding model was less sensitive to αIIbβ3 inhibition (EC50 = 6.9 µg/ml) than tail transection or saphenous artery bleeding models (EC50 = 0.12 and 0.37 µg/ml, respectively) (95% CI = 2.4 – 20, 0.05 – 0.33, and 0.06 – 2.2 µg/ml, respectively). The EC50 of Leo.H4 for ADP-induced platelet aggregation in vitro (8.0 µg/ml) was at least 20-fold higher than that of the tail and arterial, but not the venous bleeding model. In conclusion, venous, arterial and tail bleeding models are similarly affected by impaired coagulation, while platelet function defects have a greater influence in models incorporating arterial injury.


1981 ◽  
Vol 10 (3) ◽  
pp. 165-175
Author(s):  
Graham F. Pay ◽  
Robert B. Wallis ◽  
Daniela Zelaschi
Keyword(s):  

2006 ◽  
Vol 84 (3) ◽  
pp. 561-569 ◽  
Author(s):  
Niamh O’Kennedy ◽  
Lynn Crosbie ◽  
Stuart Whelan ◽  
Vanessa Luther ◽  
Graham Horgan ◽  
...  

1987 ◽  
Author(s):  
U Cornelli ◽  
J M Welena ◽  
J Fareed ◽  
X Huan ◽  
D Hoppensteadt

Ateriod obtained from beef mucosal lining is a sulfomuco-polysaccharide mixture of various glycosaminoglycans which contains derma tans, heparatans and traces of heparin. It has been used in the treatment ofatherosclerosis and related vaso-oclusive disorders. Ateriod is standardized in terms of its lipoprotein lipase activation actions. Ateriod contains signfi-cant in vitro anticoagulant and antiprotease (anti-factor Xa and anti-factor Ila) activities as measured by clot-based and chromr ogenic substrate methods. However, this in vitro activity is 7-10 times lesser than heparin. In order to study the antithrombotic actions of this agent in subcutaneous, intravenous and oral routes, we utilized a rabbit stasis thrombosis model with a prothrombin complex concentrate/Russell's viper venom thrombogenic challenge and prolonged stasis. The apparent ED50 for the antithrombotic action were found to be: IV (75-100 ug/ kg), SC (0.8-1.3 mg/kg) and oral (20-30 mg/kg). In both the IV- and SC studies, sustained anticoagulant and antiprotease actions were evident. The observed antithrombotic actions did not relate to the anti-factor IIa or anti-factor Xa actions. Pretreatment of Ateriod with equigravimetric amounts of protamine and platelet factor 4 did not neutralize the antithrombotic actions of this agent in the rabbit model. In a primate (Macaca mulatta) model of pharmacokinetics, ex vivo analysis following subcutaneously administered Ateriod showed sustained anticoagulant and antiprotease effects. The time course of the subcutaneously administered Ateriod was markedly different than heparin and a low molecular weight heparin. Treated animals were shown to resist induced hypercoagulability following injection of homologous serum as measured by FPA generation for extended periods. These studies suggest that Ateriod produces a strong antithrombotic action and that it has highly sustained pharmacokinetics. The antithrombotic activity appears to be primarily mediated via non-antithrombin - HI dependent events which may be related to heparin cofactor II and vascular/ cellular modifications.


Blood ◽  
2015 ◽  
Vol 126 (23) ◽  
pp. 3442-3442 ◽  
Author(s):  
Reheman Adili ◽  
Theodore R Holman ◽  
Michael Holinstat

Abstract Background: Adequate platelet reactivity is required for platelet adhesion and aggregation at the site of vascular injury to maintain hemostasis. However, excessive platelet reactivity can also lead to the formation of occlusive thrombi, the predominate underlying cause of myocardial infarction and stroke. While current anti-platelet treatments limit platelet function, they often result in an increased risk of bleeding. 12-lipoxygenase (12-LOX), an oxygenase highly expressed in the platelet, has been demonstrated by our lab and others to regulate PAR4 and GPVI-mediated platelet reactivity suggesting a role of 12-LOX in regulation of vivo thrombosis. However, the ability to pharmacologically target 12-LOX in vivo has not been established to date. Aims: To determine how 12-LOX regulates thrombus formation in vivo and whether platelet 12-LOX is an effective target for anti-platelet therapeutics, wild-type (WT) or 12-LOX deficient (12-LOX-/-) mice were treated with or without the 12-LOX inhibitor, ML355, and were assessed for inhibitory effects on platelet activation in vitro, ex-vivo and in vivo. Methods: The effect of the novel 12-LOX inhibitor ML355 on human platelet function was assessed in vitro by platelet aggregometry, ex vivo by perfusion chamber. In vivo thrombus formation and vessel occlusion in small and large vessels were studied in 12-LOX-/-, WT mice and mice treated with ML355 using intravital microscopy using the FeCl3 injury models. Results: Using in vitro platelet aggregation assays, ML355 dose dependently inhibited thrombin, PAR1-AP, and PAR4-AP-induced aggregation in washed human platelets. Interestingly, the negative regulatory effects of ML355 inhibition of 12-LOX can be overcome by high concentration of thrombin. Additionally, ML355 was able to attenuate ADP-induced platelet aggregation both in platelet-rich-plasma and whole blood. In ex vivo flow chamber assays, platelet adhesion and thrombus formation on collagen-coated surfaces at high shear was attenuated in both mouse and human whole blood after incubation with ML355. Further, platelet aggregation and thrombus growth in 12-LOX-/- mice was impaired in FeCl3-induced mesenteric or carotid artery thrombosis models. Thrombi in 12-LOX-/- mice were unstable and frequently form emboli, which resulted in impaired vessel occlusion or reopening. Additionally, thrombus formation and vessel occlusion was impaired in ML355 treated WT mice. Conclusions: The highly selective 12-LOX inhibitor ML355 inhibits platelets aggregation induced by various platelet agonists and ML355 inhibition of platelet function is not agonist specific. Platelet function at high shear in ex vivo conditions in both mice and human was attenuated in the presence of ML355. Thrombus growth, stability, and vessel occlusion was impaired in mice deficient for 12-LOX. Finally, the highly selective 12-LOX inhibitor ML355 attenuates thrombus formation and prevents vessel occlusion in vivo. Our data strongly indicates 12- LOX is an important determinant of platelet reactivity and inhibition of platelet 12-LOX may represent a new target for anti-platelet therapeutics. Disclosures No relevant conflicts of interest to declare.


Cells ◽  
2021 ◽  
Vol 10 (10) ◽  
pp. 2737
Author(s):  
Benedetta Izzi ◽  
Alessandro Gialluisi ◽  
Francesco Gianfagna ◽  
Sabatino Orlandi ◽  
Amalia De Curtis ◽  
...  

Defined as an index of platelet size heterogeneity, the platelet distribution width (PDW) is still a poorly characterized marker of platelet function in (sub)clinical disease. We presently validated PDW as a marker of P-selectin dependent platelet activation in the Moli-family cohort. Platelet-bound P-selectin and platelet/leukocyte mixed aggregates were measured by flow cytometry in freshly collected venous blood, both before and after in vitro platelet activation, and coagulation time was assessed in unstimulated and LPS- or TNFα-stimulated whole blood. Closure Times (CT) were measured in a Platelet Function Analyzer (PFA)-100. Multivariable linear mixed effect regression models (with age, sex and platelet count as fixed and family structure as random effect) revealed PDW to be negatively associated with platelet P-selectin, platelet/leukocyte aggregates and von Willebrand factor (VWF), and positively with PFA-100 CT, and LPS- and TNF-α-stimulated coagulation times. With the exception of VWF, all relationships were sex-independent. In contrast, no association was found between mean platelet volume (MPV) and these variables. PDW seems a simple, useful marker of ex vivo and in vitro P-selectin dependent platelet activation. Investigations of larger cohorts will define the usefulness of PDW as a risk predictor of thrombo-inflammatory conditions where activated platelets play a contributing role.


1994 ◽  
Vol 72 (06) ◽  
pp. 912-918 ◽  
Author(s):  
M Gawaz ◽  
I Ott ◽  
A J Reininger ◽  
F-J Neumann

SummaryMagnesium deficiency and its association with platelet hyperreactivity has been well recognised in a variety of diseases including myocardial infarction, preeclampsia, and diabetes. In order to investigate potential effects of intravenous Mg2+ supplementation, platelet function was studied by measurements of in vitro bleeding time (BT) and of fibrinogen (Fg)-mediated aggregation of washed platelets. In addition, the effect of Mg2+ on platelet adhesion onto immobilised Fg, on Fg binding to activated platelets, and on surface expression of GMP-140 or GP53 was evaluated. Mg2+(4 mM) prolonged in vitro BT by 30% and inhibited Fg-mediated aggregation significantly, independent of the agonist used to initiate platelet aggregation (ADP, collagen, epinephrine, thrombin, phorbol ester). Adhesion of resting platelets to immobilised Fg was reduced by 50% in the presence of 2 mM Mg2+. Moreover, Mg2+ reduced Fg binding to ADP- or collagen-stimulated platelets as well as surface expression of GMP-140 with an IC50 of approximately 3 mM. Intravenous administration of Mg2+ to healthy volunteers inhibited both ADP-induced platelet aggregation (p <0.05) by 40% and binding of Fg or surface expression of GMP-140 by 30% (p <0.05). Thus, pharmacological concentrations of Mg2+ effectively inhibit platelet function in vitro and ex vivo.


Sign in / Sign up

Export Citation Format

Share Document