scholarly journals Performance comparison of the solar-driven supercritical organic Rankine cycle coupled with the vapour-compression refrigeration cycle

Clean Energy ◽  
2021 ◽  
Vol 5 (3) ◽  
pp. 476-491
Author(s):  
Yunis Khan ◽  
Radhey Shyam Mishra

Abstract In this study, a parametric analysis was performed of a supercritical organic Rankine cycle driven by solar parabolic trough collectors (PTCs) coupled with a vapour-compression refrigeration cycle simultaneously for cooling and power production. Thermal efficiency, exergy efficiency, exergy destruction and the coefficient of performance of the cogeneration system were considered to be performance parameters. A computer program was developed in engineering equation-solver software for analysis. Influences of the PTC design parameters (solar irradiation, solar-beam incidence angle and velocity of the heat-transfer fluid in the absorber tube), turbine inlet pressure, condenser and evaporator temperature on system performance were discussed. Furthermore, the performance of the cogeneration system was also compared with and without PTCs. It was concluded that it was necessary to design the PTCs carefully in order to achieve better cogeneration performance. The highest values of exergy efficiency, thermal efficiency and exergy destruction of the cogeneration system were 92.9%, 51.13% and 1437 kW, respectively, at 0.95 kW/m2 of solar irradiation based on working fluid R227ea, but the highest coefficient of performance was found to be 2.278 on the basis of working fluid R134a. It was also obtained from the results that PTCs accounted for 76.32% of the total exergy destruction of the overall system and the cogeneration system performed well without considering solar performance.

2019 ◽  
Vol 9 (23) ◽  
pp. 5028 ◽  
Author(s):  
Pektezel ◽  
Acar

This paper presents energy and exergy analysis of two vapor compression refrigeration cycles powered by organic Rankine cycle. Refrigeration cycle of combined system was designed with single and dual evaporators. R134a, R1234ze(E), R227ea, and R600a fluids were used as working fluids in combined systems. Influences of different parameters such as evaporator, condenser, boiler temperatures, and turbine and compressor isentropic efficiencies on COPsys and ƞex,sys were analyzed. Second law efficiency, degree of thermodynamic perfection, exergy destruction rate, and exergy destruction ratio were detected for each component in systems. R600a was determined as the most efficient working fluid for proposed systems. Both COPsys and ƞex,sys of combined ORC-single evaporator VCR cycle was detected to be higher than the system with dual evaporator.


Entropy ◽  
2020 ◽  
Vol 22 (6) ◽  
pp. 702
Author(s):  
Bourhan Tashtoush ◽  
Tatiana Morosuk ◽  
Jigar Chudasama

Solar energy is utilized in a combined ejector refrigeration system with an organic Rankine cycle (ORC) to produce a cooling effect and generate electrical power. This study aims at increasing the utilized share of the collected solar thermal energy by inserting an ORC into the system. As the ejector refrigeration cycle reaches its maximum coefficient of performance (COP), the ORC starts working and generating electrical power. This electricity is used to run the circulating pumps and the control system, which makes the system autonomous. For the ejector refrigeration system, R134a refrigerant is selected as the working fluid for its performance characteristics and environmentally friendly nature. The COP of 0.53 was obtained for the ejector refrigeration cycle. The combined cycle of the solar ejector refrigeration and ORC is modeled in EBSILON Professional. Different parameters like generator temperature and pressure, condenser temperature and pressure, and entrainment ratio are studied, and the effect of these parameters on the cycle COP is investigated. Exergy, economic, and exergoeconomic analyses of the hybrid system are carried out to identify the thermodynamic and cost inefficiencies present in various components of the system.


Author(s):  
Kenneth C. Brown

A remote area power supply using cold thermal storage and wind as the energy source is proposed. The primary objective is to provide a renewable energy remote area power supply with cheaper and more robust storage than lead-acid batteries. The proposal amalgamates a vapour compression refrigeration system with a Rankine cycle engine, both using the same working fluid. A tank of freezing brine acts as the condenser in the Rankine cycle and as the evaporator in the refrigeration cycle but also provides the “energy storage”. Analysis of the system indicates that it is practical and that its performance is comparable with existing battery based systems.


Author(s):  
Mauro Reini

In recent years, a big effort has been made to improve microturbines thermal efficiency, in order to approach 40%. Two main options may be considered: i) a wide usage of advanced materials for hot ends components, like impeller and recuperator; ii) implementing more complicated thermodynamic cycle, like combined cycle. In the frame of the second option, the paper deals with the hypothesis of bottoming a low pressure ratio, recuperated gas cycle, typically realized in actual microturbines, with an Organic Rankine Cycle (ORC). The object is to evaluate the expected nominal performance parameters of the integrated-combined cycle cogeneration system, taking account of different options for working fluid, vapor pressure and component’s performance parameters. Both options of recuperated and not recuperated bottom cycles are discussed, in relation with ORC working fluid nature and possible stack temperature for microturbine exhaust gases. Finally, some preliminary consideration about the arrangement of the combined cycle unit, and the effects of possible future progress of gas cycle microturbines are presented.


2016 ◽  
Vol 831 ◽  
pp. 306-315
Author(s):  
Qing Quan Wang ◽  
Sławomir Smoleń

This paper explores the optimization cases for overcritical Organic Rankine Cycle (ORC) in various situations. First the ORC optimization in terms of working fluid selection is discussed. In this case, thermal efficiencies for 10 different working fluids have been calculated under certain temperature frames and the results are compared. Second, overcritical optimization case in terms of variation of hot temperature and evaporation pressure is presented. In this overcritical ORC case, the influence of evaporation pressure on ORC thermal efficiency is studied by conducting a case study of R234a, and first 1-D freedom optimization case is discussed within the variation of evaporation pressure. 2-D freedom optimization is also considered, in which the two independent variables, hot temperature and evaporation pressure, are both varied within certain boundaries. This study employs numerical method for this 2-D problem and it is also presented in detail in the case study.


2018 ◽  
Vol 31 ◽  
pp. 01002 ◽  
Author(s):  
Grano Prabumukti ◽  
Widodo Wahyu Purwanto

Indonesia posses 40% of the world's geothermal energy sources. The existence of hydrothermal sources is usually characterized by their surface manifestations such as hot springs, geysers and fumarole. Hot spring has a potential to be used as a heat source to generate electricity especially in a rural and isolated area. Hot springs can be converted into electricity by binary thermodynamic cycles such as Kalina cycle and ORC. The aim of this study is to obtain the best performances of cycle configuration and the potential power capacity. Simulation is conducted using UNISIM software with working fluid and its operating condition as the decision variables. The simulation result shows that R1234yf and propene with simple ORC as desired working fluid and cycle configuration. It reaches a maximum thermal efficiency up to 9.6% with a specific turbine inlet pressure. Higher temperature heat source will result a higher thermal efficiency‥ Cycle thermal efficiency varies from 4.7% to 9.6% depends on source of hot spring temperature. Power capacity that can be generated using Indonesia’s hot spring is ranged from 2 kWe to 61.2 kWe. The highest capacity located in Kawah Sirung and the least located in Kaendi.


Energies ◽  
2018 ◽  
Vol 11 (11) ◽  
pp. 3032 ◽  
Author(s):  
Xiaoli Yu ◽  
Zhi Li ◽  
Yiji Lu ◽  
Rui Huang ◽  
Anthony Roskilly

An innovative cascade cycle combining a trilateral cycle and an organic Rankine cycle (TLC-ORC) system is proposed in this paper. The proposed TLC-ORC system aims at obtaining better performance of temperature matching between working fluid and heat source, leading to better overall system performance than that of the conventional dual-loop ORC system. The proposed cascade cycle adopts TLC to replace the High-Temperature (HT) cycle of the conventional dual-loop ORC system. The comprehensive comparisons between the conventional dual-loop ORC and the proposed TLC-ORC system have been conducted using the first and second law analysis. Effects of evaporating temperature for HT and Low-Temperature (LT) cycle, as well as different HT and LT working fluids, are systematically investigated. The comparisons of exergy destruction and exergy efficiency of each component in the two systems have been studied. Results illustrate that the maximum net power output, thermal efficiency, and exergy efficiency of a conventional dual-loop ORC are 8.8 kW, 18.7%, and 50.0%, respectively, obtained by the system using cyclohexane as HT working fluid at THT,evap = 470 K and TLT,evap = 343 K. While for the TLC-ORC, the corresponding values are 11.8 kW, 25.0%, and 65.6%, obtained by the system using toluene as a HT working fluid at THT,evap = 470 K and TLT,evap = 343 K, which are 34.1%, 33.7%, and 31.2% higher than that of a conventional dual-loop ORC.


2019 ◽  
Vol 116 ◽  
pp. 00062 ◽  
Author(s):  
Parth Prajapati ◽  
Vivek Patel

The present work deals with multi objective optimization of nanofluid based Organic Rankine Cycle (ORC) to utilise waste heat energy. Working fluid considered for the study is R245ca for its good thermodynamic properties and lower Global Warming Potential (GWP) compared to the conventional fluids used in the waste heat recovery system. Heat Transfer Search (HTS) algorithm is used to optimize the objective functions which tends to maximize thermal efficiency and minimize Levelised Energy Cost (LEC). To enhance heat transfer between the working fluid and source fluid, nanoparticles are added to the source fluid. Application of nanofluids in the heat transfer system helps in maximizing recovery of the waste heat in the heat exchangers. Based on the availability and cost, CuO nanoparticles are considered for the study. Effect of Pinch Point Temperature Difference (PPTD) and concentration of nanoparticles in heat exchangers is studied and discussed. Results showed that nanofluids based ORC gives maximum thermal efficiency of 18.50% at LEC of 2.59 $/kWh. Total reduction of 7.11% in LEC can be achieved using nanofluids.


2018 ◽  
Vol 202 ◽  
pp. 02008
Author(s):  
Ke San Yam ◽  
Raja Wahiduzzaman Bin Raja Ismail ◽  
Vincent Chieng Chen Lee ◽  
Hyung Chul Jung

This paper presents a mathematical modelling on the evaluation of cooling, heating and power performance of a hybrid system of Organic Rankine Cycle and Vapour Compression Cycle. The system is assumed to be powered through solar parabolic trough collector and is able to generate a cooling power of 10 kW. Refrigerants R134a or R245fa are chosen as the working fluid of the system. The system is constructed using commercial energy modelling tool AspenPlus. Analysis is performed to determine the effect of changing the mass flow rate split ratio on the energy output. The effect of using subcritical and supercritical working fluid is also compared. Particular attention is paid toward the condition where the power output is equivalent to the energy consumption in view of creating a self-powered cooling and heating system. The result shows that the coefficient of performance for system using R245fa is higher compared to that using R134a. However, the system using R134a allows a self-powered cooling and heating system to be achieved to be achieve at a much higher mass split ratio, resulting the system to be 35% more efficient in the performance.


Sign in / Sign up

Export Citation Format

Share Document