scholarly journals P1726Non-pulmonary vein trigger of atrial fibrillation is likely to arise from low voltage area in the left atrium

2017 ◽  
Vol 38 (suppl_1) ◽  
Author(s):  
S. Kawai ◽  
Y. Mukai ◽  
S. Inoue ◽  
A. Chishaki ◽  
H. Tsutsui ◽  
...  
2019 ◽  
Vol 9 (1) ◽  
Author(s):  
Shunsuke Kawai ◽  
Yasushi Mukai ◽  
Shujiro Inoue ◽  
Daisuke Yakabe ◽  
Kazuhiro Nagaoka ◽  
...  

Author(s):  
Takashi Kaneshiro ◽  
Masashi Kamioka ◽  
Naoko Hijioka ◽  
Shinya Yamada ◽  
Tetsuro Yokokawa ◽  
...  

Background: The mechanism of esophageal thermal injury (ETI; esophageal mucosal injury and periesophageal nerve injury leading to gastric hypomotility) remains unknown when using a high-power short-duration (HP-SD) setting. This study sought to evaluate the characteristics of esophageal injuries in atrial fibrillation ablation using a HP-SD setting. Methods: After exclusion of 5 patients with their esophagus at the right portion of left atrium and 21 patients with additional ablations such as box isolation and low voltage area ablation in left atrium posterior wall, 271 consecutive patients (62±10 years, 56 women) who underwent pulmonary vein isolation by radiofrequency catheter ablation were analyzed. In the 101 patients, a HP-SD setting at 45 to 50 W with an Ablation Index module was used (HP-SD group). In the remaining 170 patients before introduction of the HP-SD setting, a conventional power setting of 20 to 30 W with contact force monitoring was used (conventional group). We performed esophagogastroduodenoscopy after pulmonary vein isolation in all patients and investigated the incidence and characteristics of ETI. Results: Although the incidence of ETI was significantly higher in the HP-SD group compared with the conventional group (37% versus 22%, P =0.011), the prevalence of esophageal lesions did not differ between the groups (7% versus 8%). Multivariate logistic regression analysis revealed that the use of the HP-SD setting (odds ratio, 6.09, P <0.001), and the parameters that suggest anatomic proximity surrounding the esophagus, were independent predictors of ETI. However, the majority of ETI in the HP-SD group was gastric hypomotility, and the thermal injury was limited to the shallow layer of the periesophageal wall using the HP-SD setting. Conclusions: Although the use of the HP-SD setting was a strong predictor of ETI, it could avoid deeper thermal injuries that reach the esophageal mucosal layer.


2021 ◽  
Vol 42 (Supplement_1) ◽  
Author(s):  
P Adragao ◽  
D Nascimento Matos ◽  
F Costa ◽  
P Galvao Santos ◽  
G Rodrigues ◽  
...  

Abstract Introduction Twenty years ago, pulmonary veins (PV) ostia were identified as the left atrium (LA) areas with the shortest refractory period during sinus rhythm. Pulmonary veins isolation (PVI) became standard of care, but clinical results are still suboptimal. Today, a special tool using the Carto® electroanatomical mapping (EAM) allows for AF cycle length mapping (CLM), to identify the areas in the left atria with shortest refractory period, during atrial fibrillation. Using this EAM tool, our study aimed to find the LA areas with the shortest refractory period to better recognize electrical targets for catheter ablation. Methods Retrospective analysis of an unicentric registry of individuals with symptomatic drug-refractory AF who underwent PVI with Carto® EAM. CLM was performed with a high-density mapping Pentaray® catheter before and after PVI and in 4 redo procedures. We assessed areas of short cycle length (SCL) (defined as 120 to 250ms), and their relationships with complex fractionated atrial electrograms (CFAE), and low-voltage zones (from 0.1 to 0.3mV). Results A total of 18 patients (8 men, median age 63 IQR 58–71 years) were included. Most patients presented with persistent AF (n=12, 67%), and 4 patients (22%) had a previous PVI. The mean shortest measured cycle length in AF was 140ms (SD ±27ms). All patients presented areas of SCL located in the PVs or their insertion, 70% in the posterior/roof region adjacent to the left superior pulmonary vein (LSPV) (figure 1) and 60% in the anterior region of the right superior pulmonary vein (RSPV). These two areas remained the fastest even after PVI. The anterior mitral region rarely presented SCL (17%). SCL were related to low-voltage areas in 94% and were adjacent to CFAE. Low-voltage areas and CFAE were more frequent and had a larger LA dispersion than SCL. Conclusion We confirmed in 3D mapping that PVs are the LA zones with shortest refractory period, not only in sinus rhythm but also during AF. The persistence of SCL areas in the border zones of the PVI lines suggest the benefit of a more extensive CLM guided ablation. Larger studies are needed. FUNDunding Acknowledgement Type of funding sources: None. Short cycle length mapping


EP Europace ◽  
2021 ◽  
Vol 23 (Supplement_3) ◽  
Author(s):  
P Adragao ◽  
D Nascimento Matos ◽  
F Costa ◽  
P Galvao Santos ◽  
G Rodrigues ◽  
...  

Abstract Funding Acknowledgements Type of funding sources: None. Introduction Twenty years ago, pulmonary veins (PV) ostia were identified as the left atrium (LA) areas with the shortest refractory period during sinus rhythm. Pulmonary veins isolation (PVI) became standard of care, but clinical results are still suboptimal. Today, a special tool using the Carto® electroanatomical mapping (EAM) allows for AF cycle length mapping (CLM), to identify the areas in the left atria with shortest refractory period, during atrial fibrillation. Using this EAM tool, our study aimed to find the LA areas with the shortest refractory period to better recognize electrical targets for catheter ablation. Methods Retrospective analysis of an unicentric registry of individuals with symptomatic drug-refractory AF who underwent PVI with Carto® EAM. CLM was performed with a high-density mapping Pentaray® catheter before and after PVI and in 4 redo procedures. We assessed areas of short cycle length (SCL) (defined as 120 to 250ms), and their relationships with complex fractionated atrial electrograms (CFAE), and low-voltage zones (from 0.1 to 0.3mV). Results A total of 18 patients (8 men, median age 63 IQR 58-71 years) were included. Most patients presented with persistent AF (n = 12, 67%), and 4 patients (22%) had a previous PVI. The mean shortest measured cycle length in AF was 140ms (SD ±27ms). All patients presented areas of SCL located in the PVs or their insertion, 70% in the posterior/roof region adjacent to the left superior pulmonary vein (LSPV) (figure 1) and 60% in the anterior region of the right superior pulmonary vein (RSPV). These two areas remained the fastest even after PVI. The anterior mitral region rarely presented SCL (17%). SCL were related to low-voltage areas in 94% and were adjacent to CFAE. Low-voltage areas and CFAE were more frequent and had a larger LA dispersion than SCL. Conclusion   We confirmed in 3D mapping that PVs are the LA zones with shortest refractory period, not only in sinus rhythm but also during AF. The persistence of SCL areas in the border zones of the PVI lines suggest the benefit of a more extensive CLM guided ablation. Larger studies are needed. Abstract Figure 1


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Yan-Jing Wang ◽  
Huan Sun ◽  
Xiao-Fei Fan ◽  
Meng-Chao Zhang ◽  
Ping Yang ◽  
...  

Abstract Background The ablation targets of atrial fibrillation (AF) are adjacent to bronchi and pulmonary arteries (PAs). We used computed tomography (CT) to evaluate the anatomical correlation between left atrium (LA)-pulmonary vein (PV) and adjacent structures. Methods Data were collected from 126 consecutive patients using coronary artery CT angiography. The LA roof was divided into three layers and nine points. The minimal spatial distances from the nine points and four PV orifices to the adjacent bronchi and PAs were measured. The distances from the PV orifices to the nearest contact points of the PVs, bronchi, and PAs were measured. Results The anterior points of the LA roof were farther to the bronchi than the middle or posterior points. The distances from the nine points to the PAs were shorter than those to the bronchi (5.19 ± 3.33 mm vs 8.62 ± 3.07 mm; P < .001). The bilateral superior PV orifices, especially the right superior PV orifices were closer to the PAs than the inferior PV orifices (left superior PV: 7.59 ± 4.14 mm; right superior PV: 4.43 ± 2.51 mm; left inferior PV: 24.74 ± 5.26 mm; right inferior PV: 22.33 ± 4.75 mm) (P < .001). Conclusions The right superior PV orifices were closer to the bronchi and PAs than other PV orifices. The ablation at the mid-posterior LA roof had a higher possibility to damage bronchi. CT is a feasible method to assess the anatomical adjacency in vivo, which might provide guidance for AF ablation.


EP Europace ◽  
2020 ◽  
Vol 22 (Supplement_1) ◽  
Author(s):  
A P Martin ◽  
M Fowler ◽  
N Lever

Abstract Background Pulmonary vein isolation using cryotherapy is an established treatment for the management of patients with paroxysmal atrial fibrillation. Ablation using the commercially available balloon cryocatheter has been shown to create wide antral pulmonary vein isolation. A novel balloon cryocatheter (BCC) has been designed to maintain uniform pressure and size during ablation, potentially improving contact with the antral anatomy. The extent of ablation created using the novel BCC has not previously been established. Purpose To determine the anatomical extent of pulmonary vein isolation using electroanatomical mapping when performing catheter ablation for paroxysmal atrial fibrillation using the novel BCC. Methods Nine consecutive patients underwent pre-procedure computed tomography angiography of the left atrium to quantify the chamber dimensions. An electroanatomical map was created using the cryoablation system mapping catheter and a high definition mapping system. A bipolar voltage map was obtained following ablation to determine the extent of pulmonary vein isolation ablation. A volumetric technique was used to quantify the extent of vein and posterior wall electrical isolation in addition to traditional techniques for proving entrance and exit block. Results All patients had paroxysmal atrial fibrillation, mean age 56 years, 7 (78%) male. Electrical isolation was achieved for 100% of the pulmonary veins; mean total procedure time was 109 min (+/- 26 SD), and fluoroscopy time 14.9 min (+/- 2.4 SD). The median treatment applications per vein was one (range one - four), and median treatment duration 180 sec (range 180 -240). Left atrial volume 32 mL/m2 (+/- 7 SD), and mean left atrial posterior wall area 22 cm2 (+/- 4 SD). Data was available for quantitative assessment of the extent of ablation for eight patients. No lesions (0 of 32) were ostial in nature. The antral surface area of ablation was not statistically different between the left and right sided pulmonary veins (p 0.63), which were 5.9 (1.6 SD) and 5.4 (2.1 SD) cm2 respectively. In total 50% of the posterior left atrial wall was ablated.  Conclusion Pulmonary vein isolation using a novel BCC provides a wide and antral lesion set. There is significant debulking of the posterior wall of the left atrium. Abstract Figure.


Sign in / Sign up

Export Citation Format

Share Document