A Multicenter Evaluation of a Nongel Mechanical Separator Plasma Blood Collection Tube for Testing of Selected Therapeutic Drugs

2020 ◽  
Vol 5 (4) ◽  
pp. 671-685
Author(s):  
Svetlana Morosyuk ◽  
Julie Berube ◽  
Robert Christenson ◽  
Alan H B Wu ◽  
Denise Uettwiller-Geiger ◽  
...  

Abstract Background Some therapeutic drugs are unstable during sample storage in gel tubes. BD Vacutainer® Barricor™ Plasma Blood Collection Tube with nongel separator was compared with plasma gel tubes, BD Vacutainer PST™, PST II, and BD Vacutainer Serum Tube for acetaminophen, salicylate, digoxin, carbamazepine, phenytoin, valproic acid, and vancomycin during sample storage for up to 7 days. Methods Seven hospital sites enrolled 705 participants who were taking at least one selected drug. The study tubes were collected and tested at initial time (0 h), after 48 h of storage at room temperature and on day 7 (after additional 5 days of refrigerated storage). The performance of BD Barricor tube was evaluated for each drug by comparing BD Barricor samples with samples from the other tubes at 0 h from the same participant; stability was evaluated by comparing test results from the same tube at 0 h, 48 h, and 7 days. Results At 0 h, BD Barricor showed clinically equivalent results for selected therapeutic drugs compared with the other tubes, except phenytoin in BD PST. Phenytoin samples ≥20 µg/mL in BD PST had 10–12% lower values than samples in BD Barricor. During sample storage, all selected drugs remained stable for 7 days in BD Barricor and in serum aliquots. In BD PST, all drugs remained stable except phenytoin and carbamazepine and in BD PST II except for phenytoin. Conclusion The BD Barricor Tube is effective for the collection and storage of plasma blood samples for therapeutic drug monitoring without sample aliquoting.

2017 ◽  
Vol 18 (5) ◽  
pp. 1047 ◽  
Author(s):  
Alison Luk ◽  
Yafeng Ma ◽  
Pei Ding ◽  
Francis Young ◽  
Wei Chua ◽  
...  

Author(s):  
Jeffrey Chance ◽  
Julie Berube ◽  
Marita Vandersmissen ◽  
Norbert Blanckaert

Abstract: The performance of the BD Vacutainer: Tubes were drawn by routine venipuncture from 42 subjects according to a randomized draw order. Tubes were processed and centrifuged according to recommended handling procedures. Serum and plasma from the comparison tubes were aliquoted to secondary containers prior to analysis. Specimens were then tested for selected special chemistry analytes at two time intervals (initial time and after 24 h storage). Analytes tested included thyroid stimulating hormone, free thyroxine, total thyroxine, follicle stimulating hormone, luteinizing hormone, ferritin, cortisol, vitamin B12, folate, and testosterone. The data were collected and analyzed by analysis of variance and mean bias comparisons.: The performance of the BD Vacutainer: The BD VacutainerClin Chem Lab Med 2009;47:358–61.


Author(s):  
Sung Jin Jo ◽  
Hyo-jin Chae ◽  
Yong-Wha Lee ◽  
Jong Do Seo ◽  
Sang Hoon Song ◽  
...  

Background: The type of blood collection tube affects specimen quality and laboratory results. Because plasma specimens have a shorter processing time compared to serum specimens, emergency biochemistry tests use plasma. However, serum specimens remain stable after centrifugation and show more accurate results than plasma. Therefore, a quick-clotting serum separator tube (SST) is expected to be useful for shorter turnaround times and accurate results. We evaluated a new quick-clotting SST VQ-Tube<sup>TM</sup> (AB Medical, Korea) for clinical chemistry and thyroid hormone assays. Methods: One hundred volunteers from four university hospitals were recruited and peripheral blood samples were collected in quick-clotting SST VQ-Tubes<sup>TM</sup> and the commonly used SST V-Tubes<sup>TM</sup>. The obtained specimens were used for 16 clinical chemistry assays and three thyroid hormone assays. Results: The differences (%) in the test results obtained from the samples in each tube satisfied the allowable difference ranges (19 assays). The differences in the test results between the tubes satisfied the desired specifications for accuracy except for the glucose results (2.75%). The paired t-test revealed significant differences between the results of six assays but each set of results showed a good correlation. Samples were visually inspected for serum clarity and gel barrier integrity, and incomplete clotting reactions and hemolyzed serum were not observed. Conclusion: The new quick-clotting VQ-Tube<sup>TM</sup> demonstrated reliable test results compared to the commonly used SST V-Tube<sup>TM</sup>. This quick-clotting tube will provide fast test results with adequately separated serum specimens, especially for patients who need fast tests.


2018 ◽  
Vol 96 (6) ◽  
pp. 496-507 ◽  
Author(s):  
Daniel Harrison ◽  
Rosalie Ward ◽  
Sarah Bastow ◽  
Andrew Parr ◽  
Susan Macro ◽  
...  

1986 ◽  
Vol 32 (3) ◽  
pp. 523-526 ◽  
Author(s):  
M Landt ◽  
L L Norling ◽  
M Steelman ◽  
C H Smith

Abstract The Monoject Samplette (Sherwood) capillary serum-separator tube was evaluated for use in pediatric capillary blood collection. When patients' values for eight common clinical-chemical tests and five therapeutic drugs were compared with values from specimens concomitantly collected in plain Caraway tubes, only chloride and total CO2 were significantly different. The chloride differences (range 0-2 mmol/L) were considered to be clinically insignificant. Higher CO2 values in Samplette specimens were apparently ascribable to decreased loss to the atmosphere. Samplette values for therapeutic drugs were higher than corresponding Caraway values, but only the differences for digoxin were judged to be clinically significant. Both recoverable serum and the incidence of hemolysis were lower in Samplette specimens than in Caraway specimens. Storage of serum over the clots (with separator material interposed) in Samplettes for 24 h had no clinically significant effect on results for glucose or potassium. Storage of specimens for as long as 24 h had no effect on theophylline, phenytoin, and gentamicin concentrations, but phenobarbital reproducibly decreased after 24 h. We conclude that the Samplette serum-separator tube is suitable for the collection of capillary blood for many of the chemical tests commonly ordered for pediatric patients.


2019 ◽  
Vol 51 (1) ◽  
pp. 41-46
Author(s):  
Jing Hu ◽  
Qiao-Xin Zhang ◽  
Tong-Tong Xiao ◽  
Mei-Chen Pan ◽  
Ying-Mu Cai

ABSTRACT Objective To determine a method to reduce specimen hemolysis rates in pediatric blood specimens. Methods A total of 290 blood specimens from pediatric patients were classified into the capped group or uncapped group. The hemolysis index and levels of lactate dehydrogenase (LDH) were measured using an automated biochemical analyzer. Also, we performed a paired test to measure the concentration of free hemoglobin in specimens from 25 randomly selected healthy adult volunteers, using a direct spectrophotometric technique. Results The hemolytic rate of capped specimens was 2-fold higher than that of uncapped specimens. We found significant differences for LDH. Also, there was a significant difference in the concentration of free hemoglobin in the random-volunteers test. Conclusions Eliminating the residual negative pressure of vacuum blood-collection tubes was effective at reducing the macrohemolysis and/or microhemolysis rate.


Pathology ◽  
2017 ◽  
Vol 49 (7) ◽  
pp. 757-764 ◽  
Author(s):  
Catherine A. Hyland ◽  
Glenda M. Millard ◽  
Helen O'Brien ◽  
Elizna M. Schoeman ◽  
Genghis H. Lopez ◽  
...  