Spurious hemodynamic alterations resulting from light sensitive pressure transducers

1993 ◽  
Vol 21 (9) ◽  
pp. 1401-1402
Author(s):  
JEREMY S. GARRETT ◽  
DONALD D. VERNON ◽  
REED M. GARDNER
2019 ◽  
Vol 9 (3) ◽  
pp. 572 ◽  
Author(s):  
Syed Ali ◽  
Avijit Basu ◽  
Sulaiman Alfadul ◽  
Mohammad Asif

In the present study, we report the fluidization behavior of ultrafine nanopowder using the assisted fluidization technique of particle mixing, which was further superimposed with the pulsation of the inlet gas flow to the fluidized bed. The powder selected in the present study was hydrophilic nanosilica, which shows strong agglomeration behavior leading to poor fluidization hydrodynamics. For particle mixing, small proportions of inert particles of Geldart group A classification were used. The inlet gas flow to the fluidized bed was pulsed with a square wave of frequency 0.1 Hz with the help of a solenoid valve controlled using the data acquisition system (DAQ). In addition to the gas flow rate to the fluidized bed, pressure transients were carefully monitored using sensitive pressure transducers connected to the DAQ. Our results indicate a substantial reduction in the effective agglomerate size as a result of the simultaneous implementation of the assisted fluidization techniques of particle mixing and flow pulsation.


Nanomaterials ◽  
2020 ◽  
Vol 10 (2) ◽  
pp. 388 ◽  
Author(s):  
Ebrahim H. Al-Ghurabi ◽  
Mohammed Shahabuddin ◽  
Nadavala Siva Kumar ◽  
Mohammad Asif

Low-frequency flow pulsations were utilized to improve the hydrodynamics of the fluidized bed of hydrophilic ultrafine nanosilica powder with strong agglomeration behavior. A gradual fluidization of unassisted fluidized bed through stepwise velocity change was carried out over a wide range of velocities followed by a gradual defluidization process. Bed dynamics in different regions of the fluidized bed were carefully monitored using fast and sensitive pressure transducers. Next, 0.05-Hz square-wave flow pulsation was introduced, and the fluidization behavior of the pulsed fluidized bed was rigorously characterized to delineate its effect on the bed hydrodynamics by comparing it with one of the unassisted fluidized bed. Flow pulsations caused a substantial decrease in minimum fluidization velocity and effective agglomerate diameter. The frequencies and amplitudes of various events in different fluidized bed regions were determined by performing frequency domain analysis on real-time bed transient data. The pulsations and their effects promoted deagglomeration and improved homogeneity of the pulsed fluidized bed.


Processes ◽  
2020 ◽  
Vol 8 (7) ◽  
pp. 807 ◽  
Author(s):  
Mohammad Asif ◽  
Ebrahim H. Al-Ghurabi ◽  
Abdelhamid Ajbar ◽  
Nadavala Siva Kumar

The processing of fine and ultrafine particles using a fluidized bed is challenging in view of their unpredictable hydrodynamic behavior due to interparticle forces. The use of assisted fluidization techniques in such cases can be effective in improving the bed hydrodynamics. This work investigates the dynamics of pulsed fluidized bed of ultrafine nanosilica subjected to square-wave flow pulsations. The pulse duration used in this study is sufficient to allow the complete collapse of the pulsed fluidized bed between two consecutive flow pulsations. The proposed pulsation strategy is carefully implemented using electronic mass flow controllers with the help of analog output signals from data acquisition system. Given that the different regions of the fluidized bed exhibit varying dynamics, which together contribute to overall bed dynamics, the bed transients in the upper, central, and lower regions of the fluidized bed are monitored using several sensitive pressure transducers located along the height of the bed. The effect of the flow pulsation on the hydrodynamics of the fluidized bed is rigorously characterized. A significant reduction in the minimum fluidization velocity was obtained and an increase in the bed homogeneity was observed due to flow pulsations. The frequency domain analysis of the signals clearly delineated the frequency of the various events occurring during the fluidization.


2003 ◽  
Author(s):  
Yuan Mao Huang ◽  
Sheng An Yang

This study introduces an experimental method that can measure air pressures in the vane segments when a sliding-vane rotary compressor performs suction and compression phases in stable or unstable rotational speeds. When the air pressures of these two phases can be measured, the intake effect of the compressor’s inlet and the seal effect of the vane segments can be evaluated, respectively. Because a frequency converter provides unstable rotational speeds when it controls rotational speeds of a motor with a compressor, an encoder mounted on the output shaft of the motor was applied to record the angular location of the compressor rotor. Two strain gauge type pressure transducers were inserted into the cover plate of the compressor to measure air pressures in the vane segments. Comparing the signals of the encoder with pressure transducers, the air pressures in completions of suction and compression phases could be determined in stable or unstable rotational speeds. The air pressures when the compressor performed suction and compression phases were 99.5 kPa and 153 kPa, respectively, in 1400 rpm. The air pressure when the compressor performed suction phase decreased with the rotational speed faster than 800 rpm. The size or shape of the inlet port of the compressor should be enlarged or modified to provide the suction air pressure without dropping too much. The designed air pressure when the compressor performed compression phase was 244 kPa in 140 rpm, the manufacture precision of the compressor should be increased to decrease leakage.


1991 ◽  
Vol 261 (2) ◽  
pp. G263-G268 ◽  
Author(s):  
M. D. Crowell ◽  
G. Bassotti ◽  
L. J. Cheskin ◽  
M. M. Schuster ◽  
W. E. Whitehead

This study monitored high-amplitude propagated contractions (HAPCs) in ambulating subjects over a 24-h period using a new ambulatory recording system. Twelve healthy volunteers aged 34 +/- 5.96 yr participated. Approximately 12 h after a Colyte bowel prep, a small catheter (OD less than 3 mm), containing three solid-state pressure transducers spaced 5 cm apart, was positioned by flexible sigmoidoscope at 40-50 cm from the anal verge. A battery-operated data recorder sampled the pressure at each port at 1 Hz and stored the values on all ports if any port exceeded 75 mmHg. At the conclusion of the 24-h period, an X-ray was taken to confirm the location of the catheter. Fifty-four percent of all HAPCs preceded a bowel movement by less than or equal to 1 h. Forty-nine percent of all HAPCs occurred within 1 h after a high-fat meal, and 33% occurred within 1 h of morning awakening. Reverse propagated waves, not previously described in the colon, were observed in three individuals. Spontaneous high-amplitude caudally propagated contractions occur 6.9 +/- 1.5 times/24 h in the sigmoid colon in ambulating asymptomatic individuals and are temporally related to defecation and meals. Peristaltic activity is decreased during sleep. This recording technique was reliable and well tolerated in all participants.


RSC Advances ◽  
2021 ◽  
Vol 11 (23) ◽  
pp. 13898-13905
Author(s):  
Chuan Cai ◽  
He Gong ◽  
Weiping Li ◽  
Feng Gao ◽  
Qiushi Jiang ◽  
...  

A three-dimensional electrospun carbon nanofiber network was used to measure press strains with high sensitivity.


Sign in / Sign up

Export Citation Format

Share Document