Epitope Retrieval Technique: A Simple Modification that Reduces Staining Time

1997 ◽  
Vol 5 (1) ◽  
pp. 71 ◽  
Author(s):  
Kutsal Y??r??ko??lu ◽  
Sultan Cing??z
Author(s):  
Vishnu Sharma ◽  
Vijay Singh Rathore

In these days most of the software development uses preexisting software components. This approach provides plenty of benefits over the traditional development. Most of the software industries uses their own domain based software libraries where components resides in the form of modules, codes, executable file, documentations, test plans which may be used as it is or with minor changes. Due to shrinking time and high demand of software development it is necessary to use pre tested software components to ensure high functionality in software developed. Software components can be used very easily and without having the worries of errors and bugs because these are developed under expert supervision and well tested. What we have to do is just embed these components in our project. In this paper a survey got conducted over 112 software developer,testers and freelancers. In survey several issues in CBSD were identified. An efficient repository along with a component search engine is developed. All the component retrieval techniques were evaluated and compared with precise and recall method.


2013 ◽  
Vol 10 (2) ◽  
pp. 51
Author(s):  
Siti Farhana Zakaria ◽  
Keith R Millington

Polymers and organic materials that are exposed to sunlight undergo photooxidation, which leads to deterioration of their physical properties. To allow adequate performance under outdoor conditions, synthetic polymers require additives such as antioxidants and UV absorbers. A major problem with optimising polymer formulations to maximise their working life span is that accelerated weathering tests are empirical. The conditions differ significantly from real weathering situations, and samples require lengthy irradiation period. Degradation may not be apparent in the early stages of exposure, although this is when products such as hydroperoxides are formed which later cause acceleration of oxidation. A simple way of quantifying the number of free radicals presents in organic materials following exposure to light or heat is by measuring chemiluminescence (CL) emission. Most polymers emit CL when they undergo oxidative degradation, and it originates from the bimolecular reaction of macroperoxy radicals which creates an excited carbonyl.


2017 ◽  
Vol 5 (3) ◽  
pp. 54
Author(s):  
MOHAMMED ILIAS SHAIK ◽  
CHAUHAN DINESH ◽  
ESAPALLI SRINIVAS ◽  
PADIGE VINEETH ◽  
◽  
...  

1989 ◽  
Vol 21 (4-5) ◽  
pp. 87-95
Author(s):  
J. De Santis ◽  
A. A. Friedman

Overloaded anaerobic treatment systems are characterized by high concentrations of volatile fatty acids and molecular hydrogen and poor conversion of primary substrates to methane. Previous experiments with fixed–film reactors indicated that operation with reduced headspace pressures enhanced anaerobic treatment. For these studies, four suspended culture, anaerobic reactors were operated with headspace pressures maintained between 0.5 and 1.0 atm and a solids retention time of 15 days. For lightly loaded systems (0.4 g SCOD/g VSS-day) vacuum operation provided minor treatment improvements. For shock organic loads, vacuum operation proved to be more stable and to support quicker recovery from upset conditions. Based on these studies and a companion set of bioassay tests, it was concluded that: (a) a loading rate of about 1.0 g SCOD/g VSS-day represents a practical loading limit for successful anaerobic treatment, (b) a headspace pressure of approximately 0.75 atm appears to be an optimum operating pressure for anaerobic systems and (c) simple modification to existing systems may provide relief for organically overloaded systems.


1999 ◽  
Vol 8 (1) ◽  
pp. 40-46 ◽  
Author(s):  
Melisa R. Ellis ◽  
Michael K. Wynne

The loudness growth in 1/2-octave bands (LGOB) procedure has been shown previously to provide valid estimates of loudness growth for adults with normal hearing and those with hearing loss (Allen, Hall, & Jeng, 1990), and it has been widely incorporated into fitting strategies for adult hearing aid users by a hearing aid manufacturer. Here, we applied a simple modification of LGOB to children and adults with normal hearing and then compared the loudness growth functions (as obtained from end-point data) between the two age groups. In addition, reliability data obtained within a single session and between test sessions were compared between the two groups. Large differences were observed in the means between the two groups for the lower boundary values, the upper boundary values, and the range between boundaries both within and across all frequencies. The data obtained from children also had greater variance than the adult data. In addition, there was more variability in the data across test sessions for children. Many test-retest differences for children exceeded 10 dB. Adult test-retest differences were generally less than 10 dB. Although the LGOB with the modifications used in this study may be used to measure loudness growth in children, its poor reliability with this age group may limit its clinical use for children with hearing loss. Additional work is needed to explore whether loudness growth measures can be adapted successfully to children and whether these measures contribute worthwhile information for fitting hearing aids to children.


2021 ◽  
Vol 2 (1) ◽  
Author(s):  
Teunis van Manen ◽  
Shahram Janbaz ◽  
Kaspar M. B. Jansen ◽  
Amir A. Zadpoor

AbstractShape-shifting materials are a powerful tool for the fabrication of reconfigurable materials. Upon activation, not only a change in their shape but also a large shift in their material properties can be realized. As compared with the 4D printing of 2D-to-3D shape-shifting materials, the 4D printing of reconfigurable (i.e., 3D-to-3D shape-shifting) materials remains challenging. That is caused by the intrinsically 2D nature of the layer-by-layer manner of fabrication, which limits the possible shape-shifting modes of 4D printed reconfigurable materials. Here, we present a single-step production method for the fabrication and programming of 3D-to-3D shape-changing materials, which requires nothing more than a simple modification of widely available fused deposition modeling (FDM) printers. This simple modification allows the printer to print on curved surfaces. We demonstrate how this modified printer can be combined with various design strategies to achieve high levels of complexity and versatility in the 3D-to-3D shape-shifting behavior of our reconfigurable materials and devices. We showcase the potential of the proposed approach for the fabrication of deployable medical devices including deployable bifurcation stents that are otherwise extremely challenging to create.


2020 ◽  
Vol 1 (1) ◽  
Author(s):  
Stelbin Peter Figerez ◽  
Sudeshna Patra ◽  
G Rajalakshmi ◽  
Tharangattu N Narayanan

Abstract Respiratory masks having similar standards of ‘N95’, defined by the US National Institute for Occupational Safety and Health, will be highly sought after, post the current COVID-19 pandemic. Here, such a low-cost (∼$1/mask) mask design having electrostatic rechargeability and filtration efficiency of >95% with a quality factor of ∼20 kPa−1 is demonstrated. This filtration efficacy is for particles of size 300 nm. The tri-layer mask, named PPDFGO tri, contains nylon, modified polypropylene (PPY), and cotton nonwoven fabrics as three layers. The melt-spun PPY, available in a conventional N95 mask, modified with graphene oxide and polyvinylidene fluoride mixture containing paste using a simple solution casting method acts as active filtration layer. The efficacy of this tri-layer system toward triboelectric rechargeability using small mechanical agitations is demonstrated here. These triboelectric nanogenerator (TENG)-assisted membranes have high electrostatic charge retention capacity (∼1 nC/cm2 after 5 days in ambient condition) and high rechargeability even in very humid conditions (>80% RH). A simple but robust permeability measurement set up is also constructed to test these TENG-based membranes, where a flow rate of 30–35 L/min is maintained during the testing. Such a simple modification to the existing mask designs enabling their rechargeability via external mechanical disturbances, with enhanced usability for single use as well as for reuse with decontantamination, will be highly beneficial in the realm of indispensable personal protective equipment.


Radiology ◽  
1983 ◽  
Vol 146 (1) ◽  
pp. 232-232 ◽  
Author(s):  
R L Dubuisson ◽  
R P Eichelberger ◽  
T B Jones

2021 ◽  
Author(s):  
Lukas Stolz ◽  
Gerrit Homann ◽  
Martin Winter ◽  
Johannes Kasnatscheew

Cell failure of polymer electrolytes is rather the result of short circuits instead of assumed electrolyte oxidation. A spacer with a constant and defined distance can avoid this failure, thus realize a benchmark system for a more systematic R&D.


Sign in / Sign up

Export Citation Format

Share Document