Effects of 3D-bioplotted polycaprolactone scaffold geometry on human adipose-derived stem cell viability and proliferation

2017 ◽  
Vol 23 (3) ◽  
pp. 534-542 ◽  
Author(s):  
Saahil V. Mehendale ◽  
Liliana F. Mellor ◽  
Michael A. Taylor ◽  
Elizabeth G. Loboa ◽  
Rohan A. Shirwaiker

Purpose This study aims to investigate the effect of three-dimensional (3D)- bioplotted polycaprolactone (PCL) scaffold geometry on the biological and mechanical characteristics of human adipose-derived stem cell (hASC) seeded constructs. Design/methodology/approach Four 3D-bioplotted scaffold disc designs (Ø14.5 × 2 mm) with two levels of strand–pore feature sizes and two strand laydown patterns (0°/90° or 0°/120°/240°) were evaluated for hASC viability, proliferation and construct compressive stiffness after 14 days of in vitro cell culture. Findings Scaffolds with the highest porosity (smaller strand–pore size in 0°/120°/240°) yielded the highest hASC proliferation and viability. Further testing of this design in a 6-mm thick configuration showed that cells were able to penetrate and proliferate throughout the scaffold thickness. The design with the lowest porosity (larger strand–pore size in 0°/90°) had the highest compression modulus after 14 days of culture, but resulted in the lowest hASC viability. The strand laydown pattern by itself did not influence the compression modulus of scaffolds. The 14-day cell culture also did not cause significant changes in compressive properties in any of the four designs. Originality/value hASC hold great potential for musculoskeletal tissue engineering applications because of their relative ease of harvest, abundance and differentiation abilities. This study reports on the effects of 3D-bioplotted scaffold geometry on mechanical and biological characteristics of hASC-seeded PCL constructs. The results provide the basis for future studies which will use this optimal scaffold design to develop constructs for hASC-based osteochondral tissue engineering applications.

Author(s):  
James P. Kennedy ◽  
Robert W. Hitchcock

Methods of creating a scaffold for tissue engineering that allow for modification of properties such as pore size, porosity, and anisotropy are essential for tissue engineering applications. For example the pore size and material anisotropy have been shown to affect cardiomyocyte elongation and alignment [1]. Phase-inversion spray polymerization (PISP) is a method for rapidly precipitating polymers onto a surface by depositing the polymer solution simultaneously with a nonsolvent, and may be used to create biocompatible scaffolds of engineered morphological and mechanical properties by varying the solubility of the polymer in the nonsolvent [2]. We report here on the fabrication of scaffolds using different nonsolvents and methods of in-process elongation that allow for control of stiffness, anisotropy ratio, porosity, and in vitro cell culture.


2021 ◽  
Vol 8 (6) ◽  
pp. 13-21
Author(s):  
Odia Osemwegie ◽  
Lihua Lou ◽  
Ernest Smith ◽  
Seshadri Ramkumar

Nanofiber substrates have been used for various biomedical applications, including tissue regeneration, drug delivery, and in-vitro cell culture. However, despite the high volume of studies in this field, current clinical applications remain minimal. Innovations for their applications continuously generate exciting prospects. In this review, we discuss some of these novel innovations and identify critical factors to consider before their adoption for biomedical applications.


2018 ◽  
Vol 24 (2) ◽  
pp. 368-378 ◽  
Author(s):  
Fengyuan Liu ◽  
Srichand Hinduja ◽  
Paulo Bártolo

Purpose This paper aims to describe the control software of a novel manufacturing system called plasma-assisted bio-extrusion system (PABS), designed to produce complex multi-material and functionally graded scaffolds for tissue engineering applications. This fabrication system combines multiple pressure-assisted and screw-assisted printing heads and plasma jets. Control software allows the users to create single or multi-material constructs with uniform pore size or pore size gradients by changing the operation parameters, such as geometric parameters, lay-down pattern, filament distance, feed rate and layer thickness, and to produce functional graded scaffolds with different layer-by-layer coating/surface modification strategies by using the plasma modification system. Design/methodology/approach MATLAB GUI is used to develop the software, including the design of the user interface and the implementation of all mathematical programing for both multi-extrusion and plasma modification systems. Findings Based on the user definition, G programing codes are generated, enabling full integration and synchronization with the hardware of PABS. Single, multi-material and functionally graded scaffolds can be obtained by manipulating different materials, scaffold designs and processing parameters. The software is easy to use, allowing the efficient control of the PABS even for the fabrication of complex scaffolds. Originality/value This paper introduces a novel additive manufacturing system for tissue engineering applications describing in detail the software developed to control the system. This new fabrication system represents a step forward regarding the current state-of-the-art technology in the field of biomanufacturing, enabling the design and fabrication of more effective scaffolds matching the mechanical and surface characteristics of the surrounding tissue and enabling the incorporation of high number of cells uniformly distributed and the introduction of multiple cell types with positional specificity.


Author(s):  
Maxime Leblanc Latour ◽  
Maryam Tarar ◽  
Ryan J. Hickey ◽  
Charles M. Cuerrier ◽  
Isabelle Catelas ◽  
...  

AbstractPlant-derived cellulose biomaterials have recently been utilized in several tissue engineering applications. Naturally-derived cellulose scaffolds have been shown to be highly biocompatible in vivo, possess structural features of relevance to several tissues, as well as support mammalian cell invasion and proliferation. Recent work utilizing decellularized apple hypanthium tissue has shown that it possesses a pore size and properties similar to trabecular bone. In the present study, we examined the potential of apple-derived cellulose scaffolds for bone tissue engineering (BTE). Confocal microscopy revealed that the scaffolds had a suitable pore size for BTE applications. To analyze their in vitro mineralization potential, MC3T3-E1 pre-osteoblasts were seeded in either bare cellulose scaffolds or in composite scaffolds composed of cellulose and collagen I. Following chemically-induced differentiation, scaffolds were mechanically tested and evaluated for mineralization. The Young’s modulus of both types of scaffolds significantly increased after cell differentiation. Alkaline phosphatase and Alizarin Red staining further highlighted the osteogenic potential of the scaffolds. Histological sectioning of the constructs revealed complete invasion by the cells and mineralization throughout the entire constructs. Finally, scanning electron microscopy demonstrated the presence of mineral aggregates deposited on the scaffolds after differentiation, and energy-dispersive spectroscopy confirmed the presence of phosphate and calcium. In summary, our results indicate that plant-derived cellulose is a promising scaffold candidate for bone tissue engineering applications.


2010 ◽  
Vol 19 (4) ◽  
pp. 096369351001900 ◽  
Author(s):  
A. Hamlekhan ◽  
M. Mozafari ◽  
N. Nezafati ◽  
M. Azami ◽  
H. Hadipour

In this study, poly(∊-caprolactone) (PCL), gelatin (GEL) and nanocrystalline hydroxyapatite (HAp) was applied to fabricate novel PCL-GEL-HAp nanaocomposite scaffolds through a new fabrication method. With the aim of finding the best fabrication method, after testing different methods and solvents, the best method and solvents were found, and the nanocomposites were prepared through layer solvent casting combined with freeze-drying. Acetone and distillated water were used as the PCL and GEL solvents, respectively. The mechanical test showed that the increasing of the PCL weight through the scaffolds caused the improvement of the final nanocomposite mechanical behavior due to the increasing of the ultimate stress, stiffness and elastic modulus (8 MPa for 0% wt PCL to 23.5 MPa for 50% wt PCL). The biomineralization investigation of the scaffolds revealed the formation of bone-like apatite layers after immersion in simulated body fluid (SBF). In addition, the in vitro cytotoxity of the scaffolds using L929 mouse fibroblast cell line (ATCC) indicated no sign of toxicity. These results indicated that the fabricated scaffold possesses the prerequisites for bone tissue engineering applications.


Marine Drugs ◽  
2021 ◽  
Vol 19 (2) ◽  
pp. 85 ◽  
Author(s):  
Truc Cong Ho ◽  
Jin-Seok Park ◽  
Sung-Yeoul Kim ◽  
Hoyeol Lee ◽  
Ju-Sop Lim ◽  
...  

For tissue engineering applications, biodegradable scaffolds containing high molecular weights (MW) of collagen and sodium alginate have been developed and characterized. However, the properties of low MW collagen-based scaffolds have not been studied in previous research. This work examined the distinctive properties of low MW collagen-based scaffolds with alginate unmodified and modified by subcritical water. Besides, we developed a facile method to cross-link water-soluble scaffolds using glutaraldehyde in an aqueous ethanol solution. The prepared cross-linked scaffolds showed good structural properties with high porosity (~93%) and high cross-linking degree (50–60%). Compared with collagen (6000 Da)-based scaffolds, collagen (25,000 Da)-based scaffolds exhibited higher stability against collagenase degradation and lower weight loss in phosphate buffer pH 7.4. Collagen (25,000 Da)-based scaffolds with modified alginate tended to improve antioxidant capacity compared with scaffolds containing unmodified alginate. Interestingly, in vitro coagulant activity assay demonstrated that collagen (25,000 Da)-based scaffolds with modified alginate (C25-A63 and C25-A21) significantly reduced the clotting time of human plasma compared with scaffolds consisting of unmodified alginate. Although some further investigations need to be done, collagen (25,000 Da)-based scaffolds with modified alginate should be considered as a potential candidate for tissue engineering applications.


Author(s):  
Kivilcim Buyukhatipoglu ◽  
Robert Chang ◽  
Wei Sun ◽  
Alisa Morss Clyne

Tissue engineering may require precise patterning of cells and bioactive components to recreate the complex, 3D architecture of native tissue. However, it is difficult to image and track cells and bioactive factors once they are incorporated into the tissue engineered construct. These bioactive factors and cells may also need to be moved during tissue growth in vitro or after implantation in vivo to achieve the desired tissue properties, or they may need to be removed entirely prior to implantation for biosafety concerns.


Sign in / Sign up

Export Citation Format

Share Document