Architecture as a strategy for reduced energy consumption? An in-depth analysis of residential practices’ influence on the energy performance of passive houses

2014 ◽  
Vol 3 (3) ◽  
pp. 192-206 ◽  
Author(s):  
Solvår Wågø ◽  
Thomas Berker

Purpose – The purpose of this paper is to discuss how architectural solutions may influence residential practice and energy consumption. Design/methodology/approach – The paper is part of a larger study based on qualitative investigations of six energy-efficient housing projects in Norway. Here, the authors examine one of these projects, Løvåshagen in Bergen, the first Norwegian passive house flat building. Based on a combination of 14 interviews with household members and energy consumption data for all flats, the authors show how residential practices influence energy consumption. In the discussion and conclusion, the authors focus on the role of the architecture in these practices. Findings – On the one hand, Løvåshagen reflects a mainstreaming approach to sustainable building, attracting a wide array of different occupants. On the other hand, the specific add-ons that are intended to make the buildings energy efficient require new definitions of comfort and new skills to achieve the promised energy savings. This combination can explain why Løvåshagen, after four years of occupation, has a large variation in actual energy consumption. Practical implications – In designing new energy-efficient housing, greater attention should be paid to the level of end-user control and adaptability, the level of system complexity, and the need for adequate information. An alternative to the mainstreaming approach would be to actively use architecture to influence residential practices towards reduced energy consumption. Originality/value – The use of qualitative methods to analyse quantitative energy data is original and provides promising opportunities to understand the significance of residential practices regarding actual energy consumption.

2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Seyedeh Samaneh Golzan ◽  
Mina Pouyanmehr ◽  
Hassan Sadeghi Naeini

PurposeThe modular dynamic façade (MDF) concept could be an approach in a comfort-centric design through proper integration with energy-efficient buildings. This study focuses on obtaining and/or calculating an efficient angle of the MDF, which would lead to the optimum performance in daylight availability and energy consumption in a single south-faced official space located in the hot-arid climate of Yazd, Iran.Design/methodology/approachThe methodology consists of three fundamental parts: (1) based on previous related studies, a diamond-based dynamic skin façade was applied to a south-faced office building in a hot-arid climate; (2) the daylighting and energy performance of the model were simulated annually; and (3) the data obtained from the simulation were compared to reach the optimum angle of the MDF.FindingsThe results showed that when the angle of the MDF openings was set at 30°, it could decrease energy consumption by 41.32% annually, while daylight simulation pointed that the space experienced the minimum possible glare at this angle. Therefore, the angle of 30° was established as the optimum angle, which could be the basis for future investment in responsive building envelopes.Originality/valueThis angular study simultaneously assesses the daylight availability, visual comfort and energy consumption on a MDF in a hot-arid climate.


2020 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Stephen O. Eromobor ◽  
Dillip Kumar Das ◽  
Fidelis Emuze

PurposeArguments for the design of sustainable university buildings have emerged in South Africa. Energy being a major determinant of the sustainability of buildings, the purpose of this study was to examine the influence of various building and indoor environmental parameters on the energy performance of university buildings in South Africa.Design/methodology/approachA quantitative survey research method, administered within the context of university buildings in South Africa, was used. Data about 16 buildings from three universities were collected. Relevant, inferential statistical analyses were conducted to examine the relative influence of the building parameters on the energy consumed in the buildings. Also, regression models within building parameters were developed independently and in a combination that could be used to estimate energy consumption in the university buildings.FindingsFindings suggested that building and indoor environmental parameters of humidity, indoor temperature, volume, illumination, and window width ratio (WWR), in that order, influenced energy consumption significantly, and also, had direct empirical relationships.Practical implicationsOptimising the building and indoor environmental parameters in design will enhance energy-efficiency in university buildings in South Africa.Originality/valueThis study contributes to the literature in terms of understanding the order of influence of building parameters on energy consumption in university buildings in the temperate climatic zone of South Africa. It also established empirical models between building and indoor environmental parameters and energy consumption, both independently and in combination, that could assist in designing energy-efficient and sustainable university buildings.


2021 ◽  
Author(s):  
Moe Otsubo

The energy performance gap between the predicted and actual energy consumption of 3 LEED for Homes certified buildings were investigated. The actual energy consumptions of the homes were found to be 23 to 77% higher than the initial energy consumption predictions made during the design stage. Revisions to the HOT2000 models to account for changes made between the design and occupancy phase of the buildings helped reduce the gap (9 to 40%). The sources of the discrepancies were found to be related to the energy modeling program’s limitations, inconsistency between the energy model and the actual building, and additional loads in the homes. The HOT2000 program, which is used for obtaining the EnerGuide rating for LEED certified homes, was compared against a dynamic energy simulation program to assess the applicability of the use of the former for energy efficient homes. The use of EnergyPlus not only allowed for a more accurate representation of the actual homes in the energy models, but an increase in the EnerGuide rating for the home was seen, which in turn equates to additional points for the home under the “Energy & Atmosphere” category for the LEED for Homes certification process


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Elahe Mirabi ◽  
Fatemeh Akrami Abarghuie

PurposeThe earth-sheltered building is an adaptive strategy reducing energy consumption as well as increasing thermal comfort of the residents. Although this idea historically implemented in the city of Yazd, Iran, its effects on thermal comfort have not been studied thoroughly. This paper aims to discuss and analyze energy performance, in terms of parameters such as orientation, underground depth, nocturnal ventilation and its subsequent effects on thermal comfort in earth-sheltered buildings in Yazd.Design/methodology/approachUsing EnergyPlus software, the obtained numeric data are precisely modeled, simulated and analyzed.FindingsResults show that there is a direct relationship between depth of construction and energy consumption savings. The more construction depth of earth-sheltered buildings, the more percentage of energy consumption savings, that is of a higher rate in comparison to the aboveground ones. However, in south orientation, energy saving significantly reduces from depth of 2 m downwards and the annual indoor temperature fluctuation decreases by 50%. This subsequently yields to experiencing indoor thermal comfort for a significant number of days throughout the year. Considering the effects of orientation factor, the south orientation regardless of the depth provides the most desired outcome regarding energy savings.Originality/valueSimulating the model generalized to the sunken courtyard can approve that the results of this research can be applied to the other models.


2020 ◽  
Vol 12 (5) ◽  
pp. 1960
Author(s):  
Rosaura Castrillón-Mendoza ◽  
Javier M. Rey-Hernández ◽  
Francisco J. Rey-Martínez

The main target of climate change policies in the majority of industrialized countries is to reduce energy consumption in their facilities, which would reduce the carbon emissions that are generated. Through this idea, energy management plans are developed, energy reduction targets are established, and energy-efficient technologies are applied to achieve high energy savings, which are environmentally compatible. In order to evaluate the impact of their operations and investments, companies promote measures of performance in their energy management plans. An integral part of measuring energy performance is the establishment of energy baselines applicable to the complete facility that provide a basis for evaluating energy efficiency improvements and incorporating energy performance indicators. The implementation of energy management systems in accordance with the requirements of ISO Standard 50001 is a contribution to the aim and strategies for improving cleaner production in industries. This involves an option for the industry to establish energy benchmarks to evaluate performance, predict energy consumption, and align production with the lowest possible consumption of primary and secondary forms of energy. Ultimately, this goal should lead to the manufacturing of cleaner products that are environmentally friendly, energy efficient, and are in accordance with the global environmental targets of cleaner manufacturing. This paper discusses an alternative for establishing energy baselines for the industrial sector in which several products are produced from a single raw material, and we determined the energy consumption of each product and its impact on the overall efficiency of the industry at the same time. The method is applied to the plastic injection process and the result is an energy baseline (EBL) in accordance with the requirements of ISO 50001, which serves as a reference for determining energy savings. The EBL facilitates a reduction in energy consumption and greenhouse gas emissions in sectors such as plastics, a sector which accounts for 15% of Colombia’s manufacturing GDP.


2019 ◽  
Vol 8 (5) ◽  
pp. 366-390 ◽  
Author(s):  
Phan Anh Nguyen ◽  
Regina Bokel ◽  
Andy van den Dobbelsteen

Purpose Refurbishing houses is considered a key measure to improve the energy efficiency of the built environment. However, little is known about the implementation and outcome of housing renovation for energy upgrades in the Vietnamese practice. The purpose of this paper is to investigate the energy performance of the current housing stock in Vietnam and the potential to reduce energy use in households. Design/methodology/approach The paper is based on a survey with 153 respondents in three major climatic regions of Vietnam. The survey focusses on building characteristics, environmental performance, energy performance and refurbishment activities. Data collected from the survey were statistically analysed to give insight into the current performance of the housing stock and its energy saving potential. Findings This paper concludes that building design and construction, particularly the building envelope, have a significant influence on the occupants’ comfort. However, the energy consumption in houses is not statistically associated with building design and indoor environment. It is suggested that financial status and occupants’ behaviour currently have a strong influence on the household energy use. The survey also showed that refurbishment improves the housing performance, especially if improving the indoor environment was one of the drivers. Originality/value There are very few studies on energy use in households in Vietnam, especially with regards to actual energy consumption. This paper brings insights into the actual energy consumption and reveals the “performance gap” in Vietnamese housing stock.


2019 ◽  
Vol 111 ◽  
pp. 04025
Author(s):  
Paula van den Brom ◽  
Arjen Meijer ◽  
Henk Visscher

Thermal renovations are considered to be an effective measure to reduce residential energy consumption. However, they often result in lower-than-expected energy savings. In this paper, we investigate some parameters that influence the probability on lower-than-expected energy savings. We do this by comparing actual pre- and post-renovation energy consumption of 90,000 houses in the Netherlands. The results of this study confirm that the effect of the parameters differ per renovation measure. For every renovation measure, the energy performance gap post renovation plays a significant role. This implies that the use of actual energy consumption data to determine the potential energy savings could therefore help to reduce the number of renovations resulting in lower-than-expected energy savings. Also, the energy efficiency state of the building pre-renovation plays an important role. One should take into account that renovations of energy inefficient buildings more frequently result in lower-than-expected energy savings than renovations of relatively energy efficient buildings. For the type of house we found that multifamily houses more often result in lower than expected savings when building installations are improved, while single-family houses renovations more frequently result in lower energy savings than expected when the building envelope insulation is improved. These insights can contribute to the decision making process whether or not to take a certain renovation measures, they can also help to manage expectations on housing stock level and individual building level.


2021 ◽  
Author(s):  
Moe Otsubo

The energy performance gap between the predicted and actual energy consumption of 3 LEED for Homes certified buildings were investigated. The actual energy consumptions of the homes were found to be 23 to 77% higher than the initial energy consumption predictions made during the design stage. Revisions to the HOT2000 models to account for changes made between the design and occupancy phase of the buildings helped reduce the gap (9 to 40%). The sources of the discrepancies were found to be related to the energy modeling program’s limitations, inconsistency between the energy model and the actual building, and additional loads in the homes. The HOT2000 program, which is used for obtaining the EnerGuide rating for LEED certified homes, was compared against a dynamic energy simulation program to assess the applicability of the use of the former for energy efficient homes. The use of EnergyPlus not only allowed for a more accurate representation of the actual homes in the energy models, but an increase in the EnerGuide rating for the home was seen, which in turn equates to additional points for the home under the “Energy & Atmosphere” category for the LEED for Homes certification process


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Juan Carlos Ríos-Fernández

PurposeThis paper aims to study the use of cool roof technology to avoid unnecessary energy consumption in supermarkets. This will allow to reduce and even cancel the heat absorbed by the roofs, transferring it to the buildings and thus, creating more sustainable cities.Design/methodology/approachThirteen real supermarkets with cool roofs were analysed in Australia, Canada, the USA and Spain. An analysis of so many supermarkets located in different parts of the world with different climatic zones has allowed an inductive analysis, obtaining real data of energy consumption associated with the air conditioning installations for a year with and without implementing the cool roof technology.FindingsThe paper provides insights on how the use of cool roof managed to reduce the need for energy for heating, ventilating and air conditioning by between 3.5 and 38%. Additionally, this technology reduces the annual generation of carbon dioxide (CO2) emissions per square meter of supermarket up to 2.7 kgCO2/m2. It could be an economical technology to apply in new and old buildings with a period of average economic recovery of four years.Research limitations/implicationsBecause of the chosen research approach, the research results may be generalisable. Therefore, researchers are encouraged to test proposals in construction with other uses.Practical implicationsThe paper includes economic and environmental implications for the development of cool roof technology and smooths the way for its implementation to increase energy efficiency in commercial buildings.Originality/valueThis paper is an innovative contribution to the application of cool roof technology as a source of energy savings in commercial construction through the analysis of supermarkets located in different countries with different climate zones. This will help other researchers to advance in this field and facilitate the implementation of the technology.


Author(s):  
Frank J. Agraz ◽  
John Maneri

The continual rising cost of energy, existing outdated lighting technology, and inefficient lighting designs have given property owners the opportunity to improve their facilities by retrofitting their existing luminaires with an energy efficient lighting system. A lighting retrofit uses the existing electrical infrastructure to replace, relocate, or convert existing luminaires with the latest generation of cost-effective components. New lighting technology has emerged within the last 6 years that generates energy savings of 40% to 50% while maintaining existing light levels. These upgraded and field-tested solutions lower energy consumption, generate a healthy financial return on investment, and can improve both the quality and quantity of light in the task area. As with any other solution, a cost-effective lighting system must be designed and engineered carefully to accommodate the needs of each work space. Simply installing a new lamp into an existing luminaire will not necessarily guarantee substantial energy savings or an improved lighting environment. In any space that uses electric lighting, the lighting designer must evaluate potential solutions for energy consumption, maintenance concerns, delivered light levels, hostile environments, and the overall economic impact of installing and long-term operation of the new system. In this paper, the author will discuss energy efficient lighting design criteria and how a lighting designer properly engineers a retrofit project to deliver energy savings without sacrificing light levels. The discussion includes a summary of both traditional and emerging technologies, and the long-term impact on energy consumption, maintenance, return on investment, lighting quality, and delivered light levels. Paper published with permission.


Sign in / Sign up

Export Citation Format

Share Document