scholarly journals Industrial Decarbonization by a New Energy-Baseline Methodology. Case Study

2020 ◽  
Vol 12 (5) ◽  
pp. 1960
Author(s):  
Rosaura Castrillón-Mendoza ◽  
Javier M. Rey-Hernández ◽  
Francisco J. Rey-Martínez

The main target of climate change policies in the majority of industrialized countries is to reduce energy consumption in their facilities, which would reduce the carbon emissions that are generated. Through this idea, energy management plans are developed, energy reduction targets are established, and energy-efficient technologies are applied to achieve high energy savings, which are environmentally compatible. In order to evaluate the impact of their operations and investments, companies promote measures of performance in their energy management plans. An integral part of measuring energy performance is the establishment of energy baselines applicable to the complete facility that provide a basis for evaluating energy efficiency improvements and incorporating energy performance indicators. The implementation of energy management systems in accordance with the requirements of ISO Standard 50001 is a contribution to the aim and strategies for improving cleaner production in industries. This involves an option for the industry to establish energy benchmarks to evaluate performance, predict energy consumption, and align production with the lowest possible consumption of primary and secondary forms of energy. Ultimately, this goal should lead to the manufacturing of cleaner products that are environmentally friendly, energy efficient, and are in accordance with the global environmental targets of cleaner manufacturing. This paper discusses an alternative for establishing energy baselines for the industrial sector in which several products are produced from a single raw material, and we determined the energy consumption of each product and its impact on the overall efficiency of the industry at the same time. The method is applied to the plastic injection process and the result is an energy baseline (EBL) in accordance with the requirements of ISO 50001, which serves as a reference for determining energy savings. The EBL facilitates a reduction in energy consumption and greenhouse gas emissions in sectors such as plastics, a sector which accounts for 15% of Colombia’s manufacturing GDP.

2021 ◽  
Vol 13 (24) ◽  
pp. 13863
Author(s):  
Yana Akhtyrska ◽  
Franz Fuerst

This study examines the impact of energy management and productivity-enhancing measures, implemented as part of LEED Existing Buildings Operations and Management (EBOM) certification, on source energy use intensity and rental premiums of office spaces using data on four major US markets. Energy management practices, comprised of commissioning and advanced metering, may reduce energy usage. Conversely, improving air quality and occupant comfort in an effort to increase worker productivity may in turn lead to higher overall energy consumption. The willingness to pay for these features in rental office buildings is hypothesised to depend not only on the extent to which productivity gains enhance the profits of a commercial tenant but also on the lease arrangements for passing any energy savings to the tenant. We apply a difference-in-differences method at a LEED EBOM certification group level and a multi-level modelling approach with a panel data structure. The results indicate that energy management and indoor environment practices have the expected effect on energy consumption as described above. However, the magnitude of the achieved rental premiums appears to be independent of the lease type.


Energies ◽  
2020 ◽  
Vol 13 (19) ◽  
pp. 5038
Author(s):  
Goopyo Hong ◽  
Chul Kim ◽  
Jun Hong

In commercial buildings, HVAC systems are becoming a primary driver of energy consumption, which already account for 45% of the total building energy consumption. In the previous literature, researchers have studied several energy conservation measures to reduce HVAC system energy consumption. One of the effective ways is an economizer in air-handling units. Therefore, this study quantified the impact of the outdoor air fraction by economizer control type in cooling system loads based on actual air-handling unit operation data in a hospital. The optimal outdoor air fraction and energy performance for economizer control types were calculated and analyzed. The result showed that economizer controls using optimal outdoor air fraction were up to 45% more efficient in cooling loads than existing HVAC operations in the hospital. The energy savings potential was 6–14% of the differential dry-bulb temperature control, 17–27% of the differential enthalpy control, 8–17% of the differential dry-bulb temperature and high-limit differential enthalpy control, and 16–27% of the differential enthalpy and high-limit differential dry-bulb temperature control compared to the no economizer control. The result of this study will contribute to providing a better understanding of economizer controls in the hospital when the building operates in hot-humid climate regions.


2018 ◽  
Vol 77 (9) ◽  
pp. 2242-2252 ◽  
Author(s):  
M. Vaccari ◽  
P. Foladori ◽  
S. Nembrini ◽  
F. Vitali

Abstract One of the largest surveys in Europe about energy consumption in Italian wastewater treatment plants (WWTPs) is presented, based on 241 WWTPs and a total population equivalent (PE) of more than 9,000,000 PE. The study contributes towards standardised resilient data and benchmarking and to identify potentials for energy savings. In the energy benchmark, three indicators were used: specific energy consumption expressed per population equivalents (kWh PE−1 year−1), per cubic meter (kWh/m3), and per unit of chemical oxygen demand (COD) removed (kWh/kgCOD). The indicator kWh/m3, even though widely applied, resulted in a biased benchmark, because highly influenced by stormwater and infiltrations. Plants with combined networks (often used in Europe) showed an apparent better energy performance. Conversely, the indicator kWh PE−1 year−1 resulted in a more meaningful definition of a benchmark. High energy efficiency was associated with: (i) large capacity of the plant, (ii) higher COD concentration in wastewater, (iii) separate sewer systems, (iv) capacity utilisation over 80%, and (v) high organic loads, but without overloading. The 25th percentile was proposed as a benchmark for four size classes: 23 kWh PE−1 y−1 for large plants > 100,000 PE; 42 kWh PE−1 y−1 for capacity 10,000 < PE < 100,000, 48 kWh PE−1 y−1 for capacity 2,000 < PE < 10,000 and 76 kWh PE−1 y−1 for small plants < 2,000 PE.


2021 ◽  
Vol 6 (2) ◽  
pp. 03-17
Author(s):  
Gazal Dandia ◽  
◽  
Pratheek Sudhakaran ◽  
Chaitali Basu ◽  
◽  
...  

Introduction: High energy consumption by buildings is a great threat to the environment and one of the major causes of climate change. With a population of 1.4 billion people and one of the fastest-growing economies in the world, India is extremely vital for the future of global energy markets. The energy demand for construction activities continues to rise and it is responsible for over one-third of global final energy consumption. Currently, buildings in India account for 35% of total energy consumption and the value is growing by 8% annually. Around 11% of total energy consumption are attributed to the commercial sector. Energy-efficient retrofitting of the built environments created in recent decades is a pressing urban challenge. Presently, most energy-efficient retrofit projects focus mainly on the engineering aspects. In this paper, we evaluate various retrofitting options, such as passive architectural interventions, active technological interventions, or a combination of both, to create the optimum result for the selected building. Methods: Based on a literature study and case examples, we identified various energy-efficient retrofit measures, and then examined and evaluated those as applied to the case study of Awas Bhawan (Rajasthan Housing Board Headquarters), Jaipur, India. For the evaluation, we developed a simulation model using EQuest for each energy measure and calculated the resultant energy savings. Then, based on the cost of implementation and the cost of energy saved, we calculated the payback period. Finally, an optimum retrofit solution was formulated with account for the payback period and ease of installation. Results and discussion: The detailed analysis of various energy-efficient retrofit measures as applied to the case study indicates that the most feasible options for retrofit resulting in optimum energy savings with short payback periods include passive architecture measures and equipment upgrades.


Energies ◽  
2020 ◽  
Vol 13 (8) ◽  
pp. 1968 ◽  
Author(s):  
Marek Borowski ◽  
Piotr Mazur ◽  
Sławosz Kleszcz ◽  
Klaudia Zwolińska

The energy consumption of buildings is very important for both economic and environmental reasons. Newly built buildings are characterized by higher insulation and airtightness of the building envelope, and are additionally equipped with technologies that minimize energy consumption in order to meet legal requirements. In existing buildings, the modernization process should be properly planned, taking into account available technologies and implementation possibilities. Hotel buildings are characterized by a large variability of energy demand, both on a daily and a yearly basis. Monitoring systems, therefore, provide the necessary information needed for proper energy management in the building. This article presents an energy analysis of the Turówka hotel located in Wieliczka (southern Poland). The historical hotel facility is being modernized as part of the project to adapt the building to the requirements of a sustainable building. The modernization proposal includes a trigeneration system with a multifunctional reverse regenerator and control module using neural algorithms. The main purpose is to improve the energy efficiency of the building and adapt it to the requirements of low-energy buildings. The implementation of a monitoring system enables energy consumption to be reduced and improves the energy performance of the building, especially through using energy management systems and control modules. The proposed retrofit solution considers the high energy consumption, structure of the energy demand, and limits of retrofit intervention on façades.


Buildings ◽  
2020 ◽  
Vol 10 (2) ◽  
pp. 21 ◽  
Author(s):  
Khadija Jnat ◽  
Isam Shahrour ◽  
Ali Zaoui

Energy consumption in the social housing sector constitutes a major economic, social, and environmental issue, because in some countries such as France, social housing accounts for about 19% of the housing sector. In addition, this sector suffers from ageing, which results in high energy consumption, deterioration in the occupant quality of life, and high pressure on the budget of low-income occupants. The reduction of the energy consumption in this sector becomes a “must”. This reduction can be achieved through energy renovation and innovation in both energy management and occupant involvement by using smart technology. This paper presents a contribution to this goal through the investigation of the impact of smart monitoring on energy savings. The research is based on monitoring of comfort conditions in an occupied social housing residence in the North of France and the use of building thermal numerical modeling. Results of monitoring show that the indoor temperature largely exceeds the regulations requirements and the use of a smart system together with occupant involvement could lead to significant savings in heating energy consumption. The novelty in this paper concerns the use of comfort data from occupied social housing residence, occupation conditions, and building thermal modeling to estimate energy savings. The proposed methodology could be easily implemented to estimate heating energy savings in social housing buildings that lack individual energy consumption monitoring.


2019 ◽  
Vol 111 ◽  
pp. 04027
Author(s):  
Aymeric Novel ◽  
Francis Allard ◽  
Patrice Joubert

Energy performance guarantee projects aim at achieving a given energy consumption in real life conditions. Building energy consumption monitoring during operation phase often reveals that energy consumption is sensitive to building spaces use and systems operation quality, especially for buildings with high energy performance characteristics [7]. Other investigations show the impact of building users’ behaviour on energy consumption [28]. These factors must be added to climate factors for energy consumption prediction during operation phase. Number of factors and possible combinations is very high. Building energy modeling is limited regarding this issue and metamodeling has been used to solve this problem [25]. We developed metamodels that are polynomial functions using D-optimal design of experiment (DOE) approach. Such metamodels can become operational tools to use in the IPMVP framework, associated with a M&V plan. This paper shows the application of the method on a cultural building that comprises numerous systems and usages. We obtain a reliable metamodel of the energy consumption as a function of climate, operation, and space use factors. which meets IPMVP [11] and ASHRAE Guideline 14 [3] modeling uncertainties criteria. We also determine the global uncertainty resulting from predictors’ uncertainties propagation and modelling uncertainty associated with the metamodel.


2021 ◽  
Vol 13 (11) ◽  
pp. 5843
Author(s):  
Mehdi Chihib ◽  
Esther Salmerón-Manzano ◽  
Mimoun Chourak ◽  
Alberto-Jesus Perea-Moreno ◽  
Francisco Manzano-Agugliaro

The COVID-19 pandemic has caused chaos in many sectors and industries. In the energy sector, the demand has fallen drastically during the first quarter of 2020. The University of Almeria campus also declined the energy consumption in 2020, and through this study, we aimed to measure the impact of closing the campus on the energy use of its different facilities. We built our analysis based upon the dataset collected during the year 2020 and previous years; the patterns evolution through time allowed us to better understand the energy performance of each facility during this exceptional year. We rearranged the university buildings into categories, and all the categories reduced their electricity consumption share in comparison with the previous year of 2019. Furthermore, the portfolio of categories presented a wide range of ratios that varied from 56% to 98%, the library category was found to be the most influenced, and the research category was found to be the least influenced. This opened questions like why some facilities were influenced more than others? What can we do to reduce the energy use even more when the facilities are closed? The university buildings presented diverse structures that revealed differences in energy performance, which explained why the impact of such an event (COVID-19 pandemic) is not necessarily relevant to have equivalent variations. Nevertheless, some management deficiencies were detected, and some energy savings measures were proposed to achieve a minimum waste of energy.


Author(s):  
Enrico Cagno ◽  
Andrea Trianni

The attention towards the topic of reducing the energy expenditures has dramatically grown in recent crisis times that have forced firms to reduce them. This reduction in energy expenditures of a firm can be pursued through a wise energy procurement (we can call it “administrative energy efficiency”), thus with a reduction in the specific cost of energy (both electricity and other energy sources). But, the highest effective saving — for the whole system — would come from a direct reduction of the consumption, thus increasing the so-called “operational energy efficiency”, the unique true energy efficiency, implying the effort of the whole firm, since it requires a lower and wiser use of energy, and new and more efficient technologies. It is quite diffused the perception that governments are now taking measures to reach a common and more efficient environmental and energetic policy, but the effort is still not sufficient. The attention has obviously been paid towards the industrial sector, that covers about 30% of the consumption, second just after transportation: since now several actions have been taken to achieve the energy performance of buildings, but very few in the operations. Furthermore, it should be clear that to be really effective in this field governments should focus their attention on Small & Medium Enterprises (SMEs), usually less efficient than Large Enterprises (LEs), since SMEs represent the vast majority of the total number of industries and cover a consistent share of the energy consumption of a whole domestic industrial sector. This paper aims at providing an overview of the most effective interventions for reducing energy consumption in industrial operations that have been successfully implemented in a large number of case studies investigated in North America and Europe. The paper provides different scenarios according to the implementation of those interventions, characterized all by being Best Available Technologies and Practices, showing the impact on the energy consumption for a set of Italian industrial districts. The final results show that, under certain assumptions, the financial support of the most effective interventions eventually provided by governments’ energy efficiency policies, would lead to a widespread increase of the overall energy efficiency of a district with strong benefits for the whole industrial system.


2021 ◽  
Author(s):  
Tasnuva Ahmed

The building industry is striving for environmental friendly and energy efficient facility developments, as we have used most of our natural resources for comfortable living. Therefore energy efficient houses are very significant to reduce energy consumption. Thermal mass can be used as one of the many techniques of energy efficiency in the housing industry. Thermal mass can store heat in it which can be released at a later time. This behaviour of thermal mass can play a significant role in heating and cooling energy consumption of houses. This study investigates the impact of thermal mass on heating and cooling energy performance of a detached house and a row attached house, which are two main types of housing in Canada. Energy Plus simulation software has been used in the study. Also the study includes two different climatic conditions in Canada, such as Toronto and Vancouver, to envision how thermal mass behaviour changes with climates. All these different studies show thermal mass has significant impact on reduced energy consumption (15% savings in Vancouver for CCHT house) and lowering indoor air temperature. Other strategies such as insulation high R value, increased south face glazing and reduced glazing U value have been integrated with thermal mass to see energy performance in both climates. It hows more energy reduction than only thermal mass strategy. For instance, in CCHT house insulation high R value with concrete high mass reduces maximum 27% of total energy for Vancouver location.


Sign in / Sign up

Export Citation Format

Share Document