scholarly journals Indoor air-quality investigation in code for sustainable homes and passivhaus dwellings

Author(s):  
Grainne McGill ◽  
Lukumon O. Oyedele ◽  
Greg Keeffe

Purpose – Energy efficient building design strategies are growing in popularity, promoted through increased awareness of climate change, rising energy prices, global consciousness and a demand for energy security. To aid this design process, assessment tools such as Code for Sustainable Homes (CSHs) and Passivhaus were introduced in the UK. However, it is suggested that these tools prioritise energy efficiency over occupant health through a fundamental lack of attention to indoor air quality (IAQ). The purpose of this paper is to investigate IAQ in selected dwellings built using CSHs level 6, level 3 and Passivhaus homes in the UK. Design/methodology/approach – Using a case study approach, the investigation consisted of IAQ measurements during summer and winter months, occupant diaries and occupant interviews. Findings – The results from the IAQ measurements show the recommended maximum level of 1,000 ppm was breached in all three Code 6 and two Code 3 homes, with levels slightly below this limit in the two Passivhaus homes. Measurements found high levels of formaldehyde, carbon dioxide and low levels of relative humidity. Practical implications – There is a need for the adequate consideration of IAQ in sustainable assessment methods, including the use of mandatory credits to ensure occupant health is not disregarded in the drive towards zero carbon. Originality/value – These results can be used to recognise areas of improvement in the CSHs and Passivhaus standard, and the design of energy efficient homes in general. Research of this nature is essential to ensure occupant health is not sacrificed through the drive towards zero carbon.

2015 ◽  
Vol 4 (3) ◽  
pp. 329-348 ◽  
Author(s):  
Grainne McGill ◽  
Lukumon O. Oyedele ◽  
Keith McAllister

Purpose – Concern of the deterioration of indoor environmental quality as a result of energy efficient building design strategies is growing. Apprehensions of the effect of airtight, super insulated envelopes, the reduction of infiltration, and the reliance on mechanical systems to provide adequate ventilation (air supply) is promoting emerging new research in this field. The purpose of this paper is to present the results of an indoor air quality (IAQ) and thermal comfort investigation in UK energy efficient homes, through a case study investigation. Design/methodology/approach – The case study dwellings consisted of a row of six new-build homes which utilize mechanical ventilation with heat recovery (MVHR) systems, are built to an average airtightness of 2m3/m2/hr at 50 Pascal’s, and constructed without a central heating system. Physical IAQ measurements and occupant interviews were conducted during the summer and winter months over a 24-hour period, to gain information on occupant activities, perception of the interior environment, building-related health and building use. Findings – The results suggest inadequate IAQ and perceived thermal comfort, insufficient use of purge ventilation, presence of fungal growth, significant variances in heating patterns, occurrence of sick building syndrome symptoms and issues with the MVHR system. Practical implications – The findings will provide relevant data on the applicability of airtight, mechanically ventilated homes in a UK climate, with particular reference to IAQ. Originality/value – IAQ data of this nature is essentially lacking, particularly in the UK context. The findings will aid the development of effective sustainable design strategies that are appropriate to localized climatic conditions and sensitive to the health of building occupants.


2015 ◽  
Vol 14 (7) ◽  
pp. 1487-1494 ◽  
Author(s):  
Marco Arnesano ◽  
Gian Marco Revel ◽  
Filippo Pietroni ◽  
Jurgen Frick ◽  
Manuela Reichert ◽  
...  

2021 ◽  
Vol 13 (8) ◽  
pp. 4139
Author(s):  
Muriel Diaz ◽  
Mario Cools ◽  
Maureen Trebilcock ◽  
Beatriz Piderit-Moreno ◽  
Shady Attia

Between the ages of 6 and 18, children spend between 30 and 42 h a week at school, mostly indoors, where indoor environmental quality is usually deficient and does not favor learning. The difficulty of delivering indoor air quality (IAQ) in learning facilities is related to high occupancy rates and low interaction levels with windows. In non-industrialized countries, as in the cases presented, most classrooms have no mechanical ventilation, due to energy poverty and lack of normative requirements. This fact heavily impacts the indoor air quality and students’ learning outcomes. The aim of the paper is to identify the factors that determine acceptable CO2 concentrations. Therefore, it studies air quality in free-running and naturally ventilated primary schools in Chile, aiming to identify the impact of contextual, occupant, and building design factors, using CO2 concentration as a proxy for IAQ. The monitoring of CO2, temperature, and humidity revealed that indoor air CO2 concentration is above 1400 ppm most of the time, with peaks of 5000 ppm during the day, especially in winter. The statistical analysis indicates that CO2 is dependent on climate, seasonality, and indoor temperature, while it is independent of outside temperature in heated classrooms. The odds of having acceptable concentrations of CO2 are bigger when indoor temperatures are high, and there is a need to ventilate for cooling.


Facilities ◽  
2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Ulrika Uotila ◽  
Arto Saari ◽  
Juha-Matti Kalevi Junnonen ◽  
Lari Eskola

Purpose Poor indoor air quality in schools is a worldwide challenge that poses health risks to pupils and teachers. A possible response to this problem is to modify ventilation. Therefore, the purpose of this paper is to pilot a process of generating alternatives for ventilation redesign, in an early project phase, for a school to be refurbished. Here, severe problems in indoor air quality have been found in the school. Design/methodology/approach Ventilation redesign is investigated in a case study of a school, in which four alternative ventilation strategies are generated and evaluated. The analysis is mainly based on the data gathered from project meetings, site visits and the documents provided by ventilation and condition assessment consultants. Findings Four potential strategies to redesign ventilation in the case school are provided for decision-making in refurbishment in the early project phase. Moreover, the research presents several features to be considered when planning the ventilation strategy of an existing school, including the risk of alterations in air pressure through structures; the target number of pupils in classrooms; implementing and operating costs; and the size of the space that ventilation equipment requires. Research limitations/implications As this study focusses on the early project phase, it provides viewpoints to assist decision-making, but the final decision requires still more accurate calculations and simulations. Originality/value This study demonstrates the decision-making process of ventilation redesign of a school with indoor air problems and provides a set of features to be considered. Hence, it may be beneficial for building owners and municipal authorities who are engaged in planning a refurbishment of an existing building.


Arsitektura ◽  
2021 ◽  
Vol 19 (2) ◽  
pp. 167
Author(s):  
Dady Wicaksono ◽  
Sugini Sugini

<p class="Abstract"><em><span lang="EN-GB">The air pollution problem had become a big problem for many cities in the world. In line with the rapid development of these cities, the concept of sustainability also continues to develop with various solutions to overcome existing problems. To solve the air pollution problem, the authors evaluated the selected building object, The Khabele School, to see the extent of the building's contribution to overcoming the air pollution problem.  The evaluation was carried out based on the DGNB (German Sustainable Building Council) certification system, the variables measured were biotope area factor (BAF), indoor air quality, daylight factor, and zero-carbon mobility. The results reveal that indoor air quality and daylight factors could meet the desired standards, while BAF and zero-carbon mobility had not met the standard. Based on theoretical and empirical studies, this paper discussed alternative design strategies, to improve the quality of the building, so that they can contribute more to overcoming air pollution problem.</span></em></p>


2020 ◽  
Vol 18 (3) ◽  
pp. 247-257
Author(s):  
Ehsan Mousavi ◽  
Vivek Sharma ◽  
Dhaval Gajjar ◽  
Shervin Shoai Naini

Purpose The purpose of this study is to evaluate the effectiveness of the control cubes for dust control in health-care facilities. Research shows that more than 80% of pathogenic agents in hospitals are spread into the air, where they either remain airborne or deposit on the surface. At the same time, renovation and repair activities, including regular maintenance, are a necessity in active health-care facilities and a multitude of studies have documented their impact on indoor air quality. The dust that is generated by construction activities may potentially carry pathogenic agents, varying from coarse particles (≤10 µm, PM10) to fine particles (≤2.5 µm, PM2.5), including airborne bacteria, and fungal spores linked to high patient mortality in immune-compromised patients. Design/methodology/approach This study measures the impact and effectiveness of one such preventative measure, namely, the control cube (CC), on air quality during renovation and repair. CC is a temporary structure, typically made from stainless steel, around the local repair zone to minimize the spread of dust and potential microorganisms. The current paper presents a comparative analysis to identify the effectiveness of a CC equipped with the high-efficiency particulate filtration (HEPA) filter in a hospital setting by simulating construction renovation and repair work. Findings A baseline was established to measure the effectiveness of CCs and the impact of negative pressure on the indoor air quality in a hospital during simulated renovation work. Results showed that CCs are very effective in minimizing the spread of dust due to construction activities in the hospital. However, it is imperative to ensure that the air inside the CC is cleaned via filtration. Originality/value CCs are very effective, and this paper investigates the best approach for facility managers to implement this strategy.


Atmosphere ◽  
2019 ◽  
Vol 10 (12) ◽  
pp. 777 ◽  
Author(s):  
Shen Yang ◽  
Joëlle Goyette Pernot ◽  
Corinne Hager Jörin ◽  
Hélène Niculita-Hirzel ◽  
Vincent Perret ◽  
...  

As part of more stringent energy targets in Switzerland, we witness the appearance of new green-certified dwellings while many existing dwellings have undergone energy efficiency measures. These measures have led to reduced energy consumption, but rarely consider their impact on indoor air quality. Consequently, such energy renovation actions can lead to an accumulation of radon in dwellings located in radon-prone areas at doses that can affect human health. This study compared the radon levels over 650 energy-efficient dwellings in western Switzerland between green-certified (Minergie) and energy-renovated dwellings, and analyzed the building characteristics responsible of this accumulation. We found that the newly green-certified dwellings had significantly lower radon level than energy-renovated, which were green- and non-green-certified houses (geometric mean 52, 87, and 105 Bq/m3, respectively). The new dwellings with integrated mechanical ventilation exhibited lower radon concentrations. Thermal retrofitting of windows, roofs, exterior walls, and floors were associated with a higher radon level. Compared to radon measurements prior to energy renovation, we found a 20% increase in radon levels. The results highlight the need to consider indoor air quality when addressing energy savings to avoid compromising occupants’ health, and are useful for enhancing the ventilation design and energy renovation procedures in dwellings.