Discovering multivariate linear relationship securely

Author(s):  
Ningning Wu ◽  
Jing Zhang ◽  
Li Ning
Keyword(s):  
1969 ◽  
Vol 22 (01) ◽  
pp. 045-067 ◽  
Author(s):  
K Deggeller ◽  
J Vreeken

SummaryThe formation and action of human prothrombin-activating enzyme is described. The study of the formation of the enzyme leads to the following conclusions :1. The enzyme is formed from factor V, factor X and phospholipid in the presence of calcium. If one of the reagents is omitted no activity develops.2. Factor V and factor X need activation by thrombin and for instance Russell Viper Venom, respectively.3. A linear relationship exists between the inverse of factor Va concentration and the inverse of enzyme concentration.4. A linear relationship exists between the inverse of factor Xa concentration and the inverse of enzyme concentration.5. A linear relationship exists between the inverse of phospholipid concentration and the inverse of enzyme concentration at small phospholipid concentration.6. A linear relationship exists between the phospholipid concentration and the inverse of enzyme concentration at high phospholipid concentration.The study of the action of the enzyme leads to the conclusion that human prothrombin is substrate and an inhibitor if present in excess.The observed phenomena are best explained by the hypothesis that factor Va and factor Xa adsorb onto the phospholipid surface. When both factors are adsorbed close together they are active as an enzyme. This activity depends on two active centers, probably one derived from factor Va and one from factor Xa.


1966 ◽  
Vol 15 (01/02) ◽  
pp. 252-272
Author(s):  
K. M Moser ◽  
Mary Belle Frey

Summary1. Caseinolytic and fibrinolytic systems for assay of plasmin in fibrinolytic agents are described which are based upon the determinations of AE/min during the linear portion of the casein-plasmin and fibrin-plasmin reaction curves respectively. A " caseinolytic-rate " unit and “fibrinolytic-rate " unit of ÄE/min × 103 during the linear portion of the respective curves are proposed.2. Data are presented indicating that a reliably linear relationship exists between plasmin concentration and these caseinolytic - and fibrinolytic-rate units.3. Data comparing results obtained with the proposed assay techniques and previously-used casein and fibrinolytic techniques are presented.4. Formulae by which caseinolytic-rate and fibrinolytic-rate units can be roughly converted into Remmert-Cohen type plasmin units are offered.5. The theoretical and practical problems which have influenced development of assays for fibrinolytic components are discussed.6. The advantages of the plasmin “rate unit” techniques vis a vis existing assays are delineated.7. The potential application of the techniques to measurements other than the plasmin content of fibrinolytic agents is discussed.


1997 ◽  
Vol 78 (02) ◽  
pp. 855-858 ◽  
Author(s):  
Armando Tripodi ◽  
Veena Chantarangkul ◽  
Marigrazia Clerici ◽  
Barbara Negri ◽  
Pier Mannuccio Mannucci

SummaryA key issue for the reliable use of new devices for the laboratory control of oral anticoagulant therapy with the INR is their conformity to the calibration model. In the past, their adequacy has mostly been assessed empirically without reference to the calibration model and the use of International Reference Preparations (IRP) for thromboplastin. In this study we reviewed the requirements to be fulfilled and applied them to the calibration of a new near-patient testing device (TAS, Cardiovascular Diagnostics) which uses thromboplastin-containing test cards for determination of the INR. On each of 10 working days citrat- ed whole blood and plasma samples were obtained from 2 healthy subjects and 6 patients on oral anticoagulants. PT testing on whole blood and plasma was done with the TAS and parallel testing for plasma by the manual technique with the IRP CRM 149S. Conformity to the calibration model was judged satisfactory if the following requirements were met: (i) there was a linear relationship between paired log-PTs (TAS vs CRM 149S); (ii) the regression line drawn through patients data points, passed through those of normals; (iii) the precision of the calibration expressed as the CV of the slope was <3%. A good linear relationship was observed for calibration plots for plasma and whole blood (r = 0.98). Regression lines drawn through patients data points, passed through those of normals. The CVs of the slope were in both cases 2.2% and the ISIs were 0.965 and 1.000 for whole blood and plasma. In conclusion, our study shows that near-patient testing devices can be considered reliable tools to measure INR in patients on oral anticoagulants and provides guidelines for their evaluation.


2017 ◽  
Vol 2 (3) ◽  
pp. 341-346
Author(s):  
Vina Meliana

Providing compensation to employees is important for every company, including PT INTI to retain qualified employees today and in the future. PT INTI is a company whose primary based as telecommunication contractor located in Bandung. This study was conducted to determine the effect between direct financial compensation variables and indirect financial compensation toward employee performance. This research uses the descriptive method and data analysis with the path and regression analysis. The result of this research is a descriptive condition of direct and indirect financial compensation in PT INTI in the reality of 2008 is not good based on continuum line where the average percentage is 30,21% where employee expectation to incentive and celebration of the holiday is large. In addition, the simultaneous test shows that there is no linear relationship between direct compensation and indirect compensation for employee performance at PT INTI. Keywords: compensation, employee performance, financial compensation


HortScience ◽  
1998 ◽  
Vol 33 (3) ◽  
pp. 510f-511 ◽  
Author(s):  
D.C. Ferree ◽  
S.J. McArtney ◽  
D.M. Scurlock

Four French–American hybrid grape cultivars grown in a greenhouse were subjected to 5 days of 80% shade at four different times around bloom. Fruit set of `Seyval' was reduced by shade imposed before, during, or immediately after bloom. `Vidal' and `Chambourcin' were less sensitive, with fruit set reduced only by shade at bloom. Shade had little effect on fruit set of `DeChaunac'. In a second study, `Chambourcin' vines were exposed to ambient, ambient plus supplemental lights, and 30%, 50%, or 80% shade for 5 weeks beginning just prior to bloom. Fruit set was positively related to light intensity. At harvest, soluble solids, pH, and hue angle had a negative linear relationship to light level. Fruit color developed earliest and most rapidly with the reduced light treatments applied at bloom. Cluster weight was positively related to light intensity.


Proceedings ◽  
2018 ◽  
Vol 2 (13) ◽  
pp. 952 ◽  
Author(s):  
Wangi Sari ◽  
Simon Leigh ◽  
James Covington

In this paper we report on the development tungsten oxide based chemiresistive sensors for the monitoring of oxygen at low temperatures (T ≤ 400 °C) in dry and humid air. The sensors were deposited onto alumina substrate by a combination of spin coating and a photolithographic process to define the sensing area. Our results show that the sensors comply with a linear relationship over a 0 to 20% concentration range, with a high response towards oxygen. The highest response was observed at 350 °C (ΔR/Ra = 7.8) in humid and in dry air (ΔR/Ra = 18). This result is a significant improvement over our previous experiments and we believe to take the concept of a metal-oxide based oxygen sensor a step closer.


1981 ◽  
Vol 240 (5) ◽  
pp. H804-H810 ◽  
Author(s):  
H. D. Kleinert ◽  
H. R. Weiss

Blood flow and high-energy phosphate (HEP) content were determined simultaneously in multiple microregions of left ventricular subendocardium in 29 normal anesthetized open-chest rabbits by use of a new micromethod to determine whether a direct linear relationship existed between these parameters. Tissue samples weighed 1-2 mg. ATP and creatine phosphate (CP) content were quantitated in quick-frozen hearts by fluorometry at sites where tissue perfusion was measured by H2 clearance by use of bare-tipped platinum electrodes. A series of validation studies were conducted to ensure that 1) no significant damage to the tissue surrounding the electrode occurred during the period of experimentation and 2) no significant loss of biochemical constituents had occurred due to labile processes during freezing or storage of the tissue. Blood flow, ATP, and CP values averaged 79.1 +/- 24.1 (SD) ml.min-1.100 g-1, 4.9 +/- 1.3 mumol/g tissue, and 8.0 +/- 3.0 mumol/g tissue, respectively, and are similar to those reported in studies using larger tissue samples. Correlation between the heterogeneous distribution of tissue perfusion and HEP revealed no direct linear relationship between these parameters in the normal unstressed rabbit subendocardium.


Sign in / Sign up

Export Citation Format

Share Document