A high gain and low-offset current-mode instrumentation amplifier using differential difference current conveyors

Author(s):  
Ugur Cini ◽  
Emre Arslan
2017 ◽  
Vol 24 (1) ◽  
pp. 79-89
Author(s):  
Bogdan Pankiewicz

Abstract In this paper a programmable input mode instrumentation amplifier (IA) utilising second generation, multiple output current conveyors and transmission gates is presented. Its main advantage is the ability to choose a voltage or current mode of inputs by setting the voltage of two configuration nodes. The presented IA is prepared as an integrated circuit block to be used alone or as a sub-block in a microcontroller or in a field programmable gate array (FPGA), which shall condition analogue signals to be next converted by an analogue-to-digital converter (ADC). IA is designed in AMS 0.35 µm CMOS technology and the power supply is 3.3 V; the power consumption is approximately 9.1 mW. A linear input range in the voltage mode reaches ± 1.68 V or ± 250 µA in current mode. A passband of the IA is above 11 MHz. The amplifier works in class A, so its current supply is almost constant and does not cause noise disturbing nearby working precision analogue circuits.


2019 ◽  
Vol 29 (04) ◽  
pp. 2050060
Author(s):  
Mehmet Sagbas ◽  
Umut Engin Ayten

In this work, a high-performance voltage and current output instrumentation amplifier circuit is proposed. The proposed circuit also has voltage-mode (VM) and transadmittance-mode (TAM) outputs at a time. It employs a single current backward transconductance amplifier (CBTA) and a grounded resistor. It has the advantage of having low input and high output impedances which makes it easy for cascadability. The presented circuit has electronically tunable property due to the bias current of the CBTA. The validity of the proposed circuit is demonstrated by PSPICE simulations using a 0.18[Formula: see text][Formula: see text]m CMOS process with [Formula: see text][Formula: see text]V supply voltage. Simulation results show that the proposed circuit has a high common mode rejection ratio (CMRR), wide bandwidth, low offset and high gain properties.


2020 ◽  
Vol 12 (3) ◽  
pp. 168-174
Author(s):  
Rashmi Sahu ◽  
Maitraiyee Konar ◽  
Sudip Kundu

Background: Sensing of biomedical signals is crucial for monitoring of various health conditions. These signals have a very low amplitude (in μV) and a small frequency range (<500 Hz). In the presence of various common-mode interferences, biomedical signals are difficult to detect. Instrumentation amplifiers (INAs) are usually preferred to detect these signals due to their high commonmode rejection ratio (CMRR). Gain accuracy and CMRR are two important parameters associated with any INA. This article, therefore, focuses on the improvement of the gain accuracy and CMRR of a low power INA topology. Objective: The objective of this article is to achieve high gain accuracy and CMRR of low power INA by having high gain operational amplifiers (Op-Amps), which are the building blocks of the INAs. Methods: For the implementation of the Op-Amps and the INAs, the Cadence Virtuoso tool was used. All the designs and implementation were realized in 0.18 μm CMOS technology. Results: Three different Op-Amp topologies namely single-stage differential Op-Amp, folded cascode Op-Amp, and multi-stage Op-Amp were implemented. Using these Op-Amp topologies separately, three Op-Amp-based INAs were realized and compared. The INA designed using the high gain multistage Op-Amp topology of low-frequency gain of 123.89 dB achieves a CMRR of 164.1 dB, with the INA’s gain accuracy as good as 99%, which is the best when compared to the other two INAs realized using the other two Op-Amp topologies implemented. Conclusion: Using very high gain Op-Amps as the building blocks of the INA improves the gain accuracy of the INA and enhances the CMRR of the INA. The three Op-Amp-based INA designed with the multi-stage Op-Amps shows state-of-the-art characteristics as its gain accuracy is 99% and CMRR is as high as 164.1 dB. The power consumed by this INA is 29.25 μW by operating on a power supply of ±0.9V. This makes this INA highly suitable for low power measurement applications.


Author(s):  
Priyanka Gupta ◽  
Kunal Gupta ◽  
Neeta Pandey ◽  
Rajeshwari Pandey

This paper presents a novel method to realize a current mode instrumentation amplifier (CMIA) through CDBA (Current difference Buffered Amplifier). It employs two CDBAs and two resistors to obtain desired functionality. Further, it does not require any resistor matching. The gain can be set according to the resistor values. It offers high differential gain and a bandwidth, which is independent of gain. The working of the circuit is verified through PSPICE simulations using CFOA IC based CDBA realization.


2013 ◽  
Vol 22 (09) ◽  
pp. 1340001 ◽  
Author(s):  
JIUN-WEI HORNG ◽  
TO-YAO CHIU ◽  
CHING-PAO HSIAO ◽  
GUANG-TING HUANG

A current-mode universal biquadratic filter with three input terminals and one output terminal is presented. The architecture uses two current conveyors (CCs), two grounded capacitors and two grounded resistors; and can realize all standard second-order filter functions — highpass, bandpass, lowpass, notch and allpass. Moreover, the circuit still offers the following advantage features: very low active and passive sensitivities, using of grounded capacitors and resistors which is ideal for integrated circuit implementation, without requirements for critical component matching conditions and very high output impedance. The workability of the proposed circuit has been verified via HSPICE simulations using TSMC 0.18 μm, level 49 MOSFET technology.


Sign in / Sign up

Export Citation Format

Share Document