Analysis of energy consumption due to electrical charging gadgets within educational facilities

Author(s):  
Adrian Vidal ◽  
Josue Dominguez ◽  
Arturo Macgluf ◽  
Estela Fernandez ◽  
Aldo G. Vazquez ◽  
...  
2018 ◽  
Vol 1 (1) ◽  
pp. 6
Author(s):  
Dalia M. M. Yacout ◽  
Pramote Sirirote ◽  
M. M. Yacout ◽  
Dusanee Thanaboripat

In view of the up-scaling energy crises worldwide, efforts have been focusing on reducing energy consumption and replacing fossil fuels usage with renewable energy sources. Thailand is one of the developing countries that have been facing an increase in energy demand associated to its economic expansion. The development in the educational sector is one of the sectors causing an increasing energy demand.Purpose: This study aims to quantify energy usage and understand its environmental impacts in one of the educational facilities in Thailand in order to identify energy saving opportunities and improvement options related to energy consumption in this sector. Materials and Methods: The investigation included a historical energy analysis for energy utilization of the facility, an onsite energy audit and an environmental impacts assessment. A number of potential energy saving opportunities was identified; related cost savings and CO2 reduction were calculated. Additionally, the environmental impacts of energy utilization were simulated using the life cycle assessment technique. Special attention was given to potential impacts on global warming due to its direct association to fossil fuels combustion.Results and discussion: the pattern of energy utilization was identified and it clarified that the major contributor to energy utilization was energy consumption practices by students and staff of the faculty. Consequently, awareness raising of energy saving opportunities and people involvement was the major area of improvement. Results show that increasing people involvement in energy saving practices could lead to a cost saving of 46,000-120,000 USD/Year with low cost investment and a 100-240 ton CO2 reduction. Other potential savings were using motion sensors which save 30-40% of energy costs in offices and utilizing renewable solar energy as a source for electricity. This will save 13,300-33,300 USD/Year with a 7.5 years payback and 35-50 years lifetime.When assessing the associated environmental impacts to electricity production, five main categories were found to be impacted: fossil fuels depletion, respiratory inorganics formation potential, global worming potential, acidification potential and eutrophication potential. The application of the suggested energy saving opportunities will reduce the electricity consumption, lower generated air emissions from fossil fuels combustion, consequently minimize all associated impacts specially global worming potential.In Conclusion: assessing energy utilization of educational facilities is essential to reduce energy demand in an up-scaling economy. Energy analysis and onsite energy audits are efficient methods for recognizing energy utilization patterns and identifying energy saving opportunities. The implemented investigation in this study can be applied in different educational facilities. 


2015 ◽  
Vol 1119 ◽  
pp. 756-759
Author(s):  
Yoon Seok Shin ◽  
Gwang Hee Kim

Korean energy consumption accounts for about 40 percent in the architecture. Especially, Heat loss of the windows is about eight times larger than the wall or roof. In addition, the structures older than 20 years were designed with no consideration of the energy perspective, and they have low energy efficiency compared with the newly introduced structures, which leads to extreme energy consumption. Therefore, this study was conducted for the purpose of engergy performance analysis according to window type in educational facilities. This study we medeled the university library in Autocad Ecotect Ananlysis program, 3D modeling. It calcualted data that the air layer thickness has about 3.9 times more impact that the glass thickness in composition of double glass. As the result of this study, the need for the remodeling and renovation of the obsolete library in order to reduce its excessive energy consumption was highlighted.


Author(s):  
Shahzeen Z. Attari ◽  
Michael L. DeKay ◽  
Cliff I. Davidson ◽  
Wandi Bruine de Bruin

ICCTP 2009 ◽  
2009 ◽  
Author(s):  
Shunquan Huang ◽  
Siqin Yu ◽  
Zhongmin Liu

2020 ◽  
Vol 39 (4) ◽  
pp. 5449-5458
Author(s):  
A. Arokiaraj Jovith ◽  
S.V. Kasmir Raja ◽  
A. Razia Sulthana

Interference in Wireless Sensor Network (WSN) predominantly affects the performance of the WSN. Energy consumption in WSN is one of the greatest concerns in the current generation. This work presents an approach for interference measurement and interference mitigation in point to point network. The nodes are distributed in the network and interference is measured by grouping the nodes in the region of a specific diameter. Hence this approach is scalable and isextended to large scale WSN. Interference is measured in two stages. In the first stage, interference is overcome by allocating time slots to the node stations in Time Division Multiple Access (TDMA) fashion. The node area is split into larger regions and smaller regions. The time slots are allocated to smaller regions in TDMA fashion. A TDMA based time slot allocation algorithm is proposed in this paper to enable reuse of timeslots with minimal interference between smaller regions. In the second stage, the network density and control parameter is introduced to reduce interference in a minor level within smaller node regions. The algorithm issimulated and the system is tested with varying control parameter. The node-level interference and the energy dissipation at nodes are captured by varying the node density of the network. The results indicate that the proposed approach measures the interference and mitigates with minimal energy consumption at nodes and with less overhead transmission.


2019 ◽  
pp. 53-65
Author(s):  
Renata Domingos ◽  
Emeli Guarda ◽  
Elaise Gabriel ◽  
João Sanches

In the last decades, many studies have shown ample evidence that the existence of trees and vegetation around buildings can contribute to reduce the demand for energy by cooling and heating. The use of green areas in the urban environment as an effective strategy in reducing the cooling load of buildings has attracted much attention, though there is a lack of quantitative actions to apply the general idea to a specific building or location. Due to the large-scale construction of high buildings, large amounts of solar radiation are reflected and stored in the canyons of the streets. This causes higher air temperature and surface temperature in city areas compared to the rural environment and, consequently, deteriorates the urban heat island effect. The constant high temperatures lead to more air conditioning demand time, which results in a significant increase in building energy consumption. In general, the shade of the trees reduces the building energy demand for air conditioning, reducing solar radiation on the walls and roofs. The increase of urban green spaces has been extensively accepted as effective in mitigating the effects of heat island and reducing energy use in buildings. However, by influencing temperatures, especially extreme, it is likely that trees also affect human health, an important economic variable of interest. Since human behavior has a major influence on maintaining environmental quality, today's urban problems such as air and water pollution, floods, excessive noise, cause serious damage to the physical and mental health of the population. By minimizing these problems, vegetation (especially trees) is generally known to provide a range of ecosystem services such as rainwater reduction, air pollution mitigation, noise reduction, etc. This study focuses on the functions of temperature regulation, improvement of external thermal comfort and cooling energy reduction, so it aims to evaluate the influence of trees on the energy consumption of a house in the mid-western Brazil, located at latitude 15 ° S, in the center of South America. The methodology adopted was computer simulation, analyzing two scenarios that deal with issues such as the influence of vegetation and tree shade on the energy consumption of a building. In this way, the methodological procedures were divided into three stages: climatic contextualization of the study region; definition of a basic dwelling, of the thermophysical properties; computational simulation for quantification of energy consumption for the four facade orientations. The results show that the façades orientated to north, east and south, without the insertion of arboreal shading, obtained higher values of annual energy consumption. With the adoption of shading, the facades obtained a consumption reduction of around 7,4%. It is concluded that shading vegetation can bring significant climatic contribution to the interior of built environments and, consequently, reduction in energy consumption, promoting improvements in the thermal comfort conditions of users.


2020 ◽  
pp. 50-64
Author(s):  
Kuladeep Kumar Sadevi ◽  
Avlokita Agrawal

With the rise in awareness of energy efficient buildings and adoption of mandatory energy conservation codes across the globe, significant change is being observed in the way the buildings are designed. With the launch of Energy Conservation Building Code (ECBC) in India, climate responsive designs and passive cooling techniques are being explored increasingly in building designs. Of all the building envelope components, roof surface has been identified as the most significant with respect to the heat gain due to the incident solar radiation on buildings, especially in tropical climatic conditions. Since ECBC specifies stringent U-Values for roof assembly, use of insulating materials is becoming popular. Along with insulation, the shading of the roof is also observed to be an important strategy for improving thermal performance of the building, especially in Warm and humid climatic conditions. This study intends to assess the impact of roof shading on building’s energy performance in comparison to that of exposed roof with insulation. A typical office building with specific geometry and schedules has been identified as base case model for this study. This building is simulated using energy modelling software ‘Design Builder’ with base case parameters as prescribed in ECBC. Further, the same building has been simulated parametrically adjusting the amount of roof insulation and roof shading simultaneously. The overall energy consumption and the envelope performance of the top floor are extracted for analysis. The results indicate that the roof shading is an effective passive cooling strategy for both naturally ventilated and air conditioned buildings in Warm and humid climates of India. It is also observed that a fully shaded roof outperforms the insulated roof as per ECBC prescription. Provision of shading over roof reduces the annual energy consumption of building in case of both insulated and uninsulated roofs. However, the impact is higher for uninsulated roofs (U-Value of 3.933 W/m2K), being 4.18% as compared to 0.59% for insulated roofs (U-Value of 0.33 W/m2K).While the general assumption is that roof insulation helps in reducing the energy consumption in tropical buildings, it is observed to be the other way when insulation is provided with roof shading. It is due to restricted heat loss during night.