Design and Development of Intelligent Substation Cluster Measurement and Control Device Based on Virtualization Technology

Author(s):  
Yuan Ji ◽  
Mingjun Yuan ◽  
Yusong Huang ◽  
Lijin Huang ◽  
Huijiang Wan ◽  
...  
2021 ◽  
Vol 4 ◽  
pp. 92-104
Author(s):  
Valentin Bahatskyi ◽  
◽  
Aleksey Bahatskyi ◽  

Currently, the measurement of electrical and non-electrical quantities is performed using analog-to-digital conversion channels, which consist of analog signal conditioning circuits and analog-to-digital converters (ADC) of electrical quantities into a digital code. The paper considers the case when the defining errors of the measurement and control channel are systematic errors of the ADC. The reliability of measurements is assessed by their errors, and the reliability of control - by the likelihood of correct operation of the control device. In our opinion, evaluating the reliability of such similar processes as measurement and control using different criteria seems illogical. The aim of the work is to study the effect of systematic errors of an analog-to-digital converter on the errors of parameter control depending on the type of conformity functions and the width of the control window, as well as the choice of the resolution of the ADC for various control tasks. The paper analyzes the transfer functions of measurement and control. It is shown that they are formed using step functions. It is proposed to use not a step function as a control transfer function, but other functions of conformity to the norm, for example, a linear function or functions of higher orders. In this case, the control result is assessed not according to the criterion of the probability of correct operation, but using the control error. Analyzed from the point of view of reconfiguring the errors of the line, parabolic and state parabolic functions of the norms for the development of changes windows in control. A recommendation has been given for the selection of functions for the conformity of standards and for the distribution of analog-to-digital conversions for industrial control enterprises.


2011 ◽  
Vol 486 ◽  
pp. 73-76
Author(s):  
Xue Feng Ma ◽  
Chao Hao ◽  
Fu Qiang Li

The deviation often appears in the feeding device of machine because of the screw spindle geometry torsional moment and the wear. The automatic compensation of the changes was proposed by means of a ball screw pretightening device by using adjustable force measurement and control. The detail design and simulation were conducted for the specific device. A case study was presented for the CNC lathe’s application. Testing results have shown that the device can be easily operated with an acceptable precision for positioning.


2011 ◽  
Vol 179-180 ◽  
pp. 824-829 ◽  
Author(s):  
Xian Min Wei

Software architecture plays a more and more important role in measurement and control program design and development. It affects not only the progress of design and development, but also the gradual evolution potentiality of measurement and control system. This paper presents a COM/DCOM based N-layer software architecture and its usage in the design and development of the WFD2000 operating program. The application of this architecture greatly improves the reliability, configurability, flexibility and portability of the pressure measurement system.


2014 ◽  
Vol 672-674 ◽  
pp. 1016-1021
Author(s):  
Qing Zhao Zeng ◽  
Jin Chuan Song ◽  
Su Zhuo Wu

VxWorks operating system provides the technical foundation for the products development of DC protective measurement and control device for mass transit. According to technical requirements of products of DC protective measurement and control device for mass transit, this paper set up software and hardware implementation scheme and deeply analyzed the key technology such as task function division, message management, interrupt management and protection task realization.The successful application experience of this technology scheme has the guide meaning for the development of the similar products.


2021 ◽  
Vol 2108 (1) ◽  
pp. 012031
Author(s):  
Yicheng Xiong ◽  
Qian Liu ◽  
Maojun Deng ◽  
Zhilei Niu

Abstract This paper studies the design scheme of a substation remote monitoring system based on GPRS, and gives the solution about poor real-time and imperfect function of centralized substation monitoring system. The working principle diagram of the measurement and control device is introduced in detail, and the modules of analog acquisition and switching input are designed. The substation remote monitoring software based on GPRS communication is developed to realize the remote real-time monitoring of electrical and switching parameters and other functions, such as data query, fault early warning and energy efficiency analysis. The experimental results show that the system has the characteristics of real-time, multi-function and high reliability. It is of great significance to implement defensive maintenance, improve power supply quality, save energy and reduce consumption.


Author(s):  
Sunday F. Iyere ◽  
Bernard O. A. Ozigi ◽  
Joseph K. Yeboah

This article focuses on the thermistor as a device that is widely used for temperature measurement and control in most electrical and electronic devices and appliances. The research is based on the type of thermistor used in photocopiers with particular reference to Minolta Bizhub (model-210) photocopier. The resistance and temperature were recorded by the application of conventional heat to deduce the response curves of resistance versus temperature and resistance/time. Results obtained from the characteristics show that the thermistor employed in the photocopier is a negative temperature coefficient (NTC) device. Also, there was a time variation in the response of the thermistor resistance to temperature changes, which indicates that the thermistor under test functions as a temperature control device. The shape of resistance versus temperature curve appeared to be similar to that of a typical NTC thermistor characteristics.