Human thermal comfort estimation in indoor space by crowd sensing

Author(s):  
Masao Chiguchi ◽  
Hirozumi Yamaguchi ◽  
Teruo Higashino ◽  
Yoshiyuki Shimoda
2008 ◽  
Author(s):  
Mohamad Al-Othmani ◽  
Nesreen Ghaddar ◽  
Kamel Ghali

In this work, human transient thermal responses and comfort are studied in non-uniform radiant heating and convective heating environments. The focus was on a change from walking activity of human in outdoor cold environment at high clothing insulation to warm indoor environment at sedentary activity level associated with lower clothing insulation. A transient multi-segmented bioheat model sensitive to radiant asymmetry is used to compare how fast the human body approaches steady state thermal conditions in both radiative and convective warm environments. A space thermal model is integrated with the bioheat model to predict the transient changes in skin and core temperature of a person subject to change in metabolic rate and clothing insulation when entering conditioned indoor space. It was found that overall thermal comfort and neutrality were reached in 6.2 minutes in the radiative environment compared to 9.24 minutes in convective environment. The local thermal comfort of various body segments differed in their response to the convective system where it took more than 19 minutes for extremities to reach local comfort unlike the radiative system where thermal comfort was attained within 7 minutes.


ICCREM 2020 ◽  
2020 ◽  
Author(s):  
Boshuai Dong ◽  
Chunjing Shang ◽  
Ming Tong ◽  
Jianhong Cai

2017 ◽  
Vol 16 (9) ◽  
pp. 2097-2111 ◽  
Author(s):  
Mohanadoss Ponraj ◽  
Yee Yong Lee ◽  
Mohd Fadhil Md Din ◽  
Zainura Zainon Noor ◽  
Kenzo Iwao ◽  
...  

Energies ◽  
2020 ◽  
Vol 13 (12) ◽  
pp. 3061 ◽  
Author(s):  
Shazia Noor ◽  
Hadeed Ashraf ◽  
Muhammad Sultan ◽  
Zahid Mahmood Khan

This study provides comprehensive details of evaporative cooling options for building air-conditioning (AC) in Multan (Pakistan). Standalone evaporative cooling and standalone vapor compression AC (VCAC) systems are commonly used in Pakistan. Therefore, seven AC system configurations comprising of direct evaporative cooling (DEC), indirect evaporative cooling (IEC), VCAC, and their possible combinations, are explored for the climatic conditions of Multan. The study aims to explore the optimum AC system configuration for the building AC from the viewpoints of cooling capacity, system performance, energy consumption, and CO2 emissions. A simulation model was designed in DesignBuilder and simulated using EnergyPlus in order to optimize the applicability of the proposed systems. The standalone VCAC and hybrid IEC-VCAC & IEC-DEC-VCAC system configurations could achieve the desired human thermal comfort. The standalone DEC resulted in a maximum COP of 4.5, whereas, it was 2.1 in case of the hybrid IEC-DEC-VCAC system. The hybrid IEC-DEC-VCAC system achieved maximum temperature gradient (21 °C) and relatively less CO2 emissions as compared to standalone VCAC. In addition, it provided maximum cooling capacity (184 kW for work input of 100 kW), which is 85% higher than the standalone DEC system. Furthermore, it achieved neutral to slightly cool human thermal comfort i.e., 0 to −1 predicted mean vote and 30% of predicted percentage dissatisfied. Thus, the study concludes the hybrid IEC-DEC-VCAC as an optimum configuration for building AC in Multan.


2021 ◽  
pp. 152808372098654
Author(s):  
Linghui Peng ◽  
Lingling Shen ◽  
Weiren Fan ◽  
Zichuan Liu ◽  
Hongbo Qiu ◽  
...  

Due to the effects of climate changing, the importance of outdoor thermal comfort has been recognized, and has gained more and more research attentions. Unlike indoor space where air conditioning can be easily implemented, outdoor thermal comfort can only be achieved by localized thermal management. Using textile is a simple but energy-saving way to realize outdoor thermal comfort. Herein, we report the design of a smart thermal management film with the silver/vanadium dioxide/silver (Ag/VO2/Ag) sandwich structure prepared by one-dimensional (1 D) nanowires. It was found that the Ag/VO2/Ag sandwich film was able to lower the temperature by around 10 °C under intense infrared (IR) radiation. In addition, the Ag/VO2/Ag sandwich structure film showed a thermo-responsive electrical conductivity and an outstanding bending stability, due to network structure formed by nanowires. It was experimentally proved that this sandwich structure was superior to other layer structures in IR shielding performance and thermo-responsive electrical conductivity. The as-prepared Ag/VO2/Ag sandwich structure film has great potential for various applications such as wearable devices, flexible electronics, medical monitors and smart IR radiation management.


2011 ◽  
Vol 243-249 ◽  
pp. 4905-4908
Author(s):  
Xue Min Sui ◽  
Xu Zhang ◽  
Guang Hui Han

Relative humidity is an important micro-climate parameter in radiant cooling environment. Based on the human thermal comfort model, this paper studied the effect on PMV index of relative humidity, and studied the relationship of low mean radiant temperature and relative humidity, drew the appropriate design range of indoor relative humidity for radiant cooling systems.The results show that high relative humidity can compensate for the impact on thermal comfort of low mean radiant temperature, on the premise of achieving the same thermal comfort requirements. However, because of the limited compensation range of relative humidity, together with the constraints for it due to anti-condensation of radiant terminal devices, the design range of relative humidity should not be improved, and it can still use the traditional air-conditioning design standards.


2014 ◽  
Vol 2014 ◽  
pp. 1-7
Author(s):  
Yu-Tuan Chou ◽  
Shao-Yi Hsia ◽  
Bi-Wen Lee

Thermal comfort providing is one of the biggest uses of energy in building. For giving better human comfort, the suitable operation conditions of air-conditioner are the most important. The quick and right approach is necessary. In this paper, a small office is studied to improve office staff staying for a long period of time and achieve the thermal comfort environment for reducing energy consumption. Commercial software, Solidworks, is utilized for modeling the facilities and the Flow Simulation module for analyzing the air properties of the indoor space. Four types of air-conditioner operation are applied to set the simulated conditions, including exterior temperature, outlet temperature and wind speed of air-conditioner, and location of air-conditioner. Predicted mean vote (PMV) and predicted percent dissatisfied (PPD) at specific office areas are further acquired through dynamic anthropometry. For seeking the optimal control factors, both of the full factorial method and Taguchi method are utilized to obtain the PMV of specified location. The analyzed result shows the evaluation speed of indoor thermal comfort by Taguchi method is faster than the full-factorial method. It is concluded that software simulation with Taguchi method shows the successful implementation and higher efficiency for thermal comfort assessment.