Thrombin generation: a comparison of assays using platelet-poor and -rich plasma and whole blood samples from healthy controls and patients with a history of venous thromboembolism

2007 ◽  
Vol 139 (1) ◽  
pp. 106-112 ◽  
Author(s):  
Kerry A. Tappenden ◽  
Michael J. Gallimore ◽  
Gillian Evans ◽  
Ian J. Mackie ◽  
David W. Jones
Blood ◽  
2020 ◽  
Vol 136 (Supplement 1) ◽  
pp. 10-11
Author(s):  
Elena Monzón Manzano ◽  
Ihosvany Fernandez-Bello ◽  
Raul Justo Sanz ◽  
Ángel Robles Marhuenda ◽  
Paula Acuña ◽  
...  

NETosis is a process suffered by neutrophils that consists in the loss of their function and the release of their nuclear material as large web-like structure called neutrophil extracelular traps (NETs). Many authors demonstrated that NETs participate in the pathogenesis of autoimmune diseases, such as systemic lupus erythematosus (SLE), because the release of autoantigens amplifies inflammatory responses, perpetuating the exacerbation of autoimmunity. On the other hand, NETs may play a prominent role in thrombosis because they serve as a negative charge scaffold to trap platelets and coagulation factors, promoting blood clot formation. Objetive: to determine participation of NETs in the hypercoagulable state of patients with SLE. Methods: 32 patients with SLE without antiphospholipid antibodies and without history of thrombotic events were included after signing informed consent; 88 sex- and age-matched healthy controls were also recruited. Blood samples were drawn in citrate tubes (3.2%). Neutrophils were isolated by centrifugation of whole blood with a Percoll gradient at 500 g, 25 min, 5ºC. To induce NETs formation, 2.5x105 isolated neutrophils were incubated in RPMI-1640 medium with or without 100 nM phorbol 12-myristate 13-acetate (PMA) for 45 min, 37ºC. To verify NETs formation, neutrophils were seeded on cover glasses pretreated with poly-L-lysine in RPMI-1640 medium with or without 100 nM PMA for 45 min, 37ºC. Samples were fixed and later incubated first, with an anti-human myeloperoxidase and then, with Alexa Fluor 488 goat anti-rabbit IgG. Finally, samples were embedded in mounting medium with DAPI and were observed by fluorescence microscopy with a Nikon Eclipse 90i microscope. Cell free DNA (cfDNA) was determined in poor platelet plasma obtained by centrifugation of whole blood (2500 g for 15 min), using the Quant-iT™ Pico Green dsDNA assay (Thermo Fisher Scientific, Waltham, MA, USA) according to the manufacturer's instructions. To assess thrombin generation associated to NETs, 2.5x105 neutrophils from patients with SLE or from controls were incubated with either buffer or 100 nM PMA during 45 min. Then they were centrifuged at 5000g, 3 min and resuspended in 40-μL of rich platelet rich plasma (PRP) from healthy controls adjusted to 106 platelets/µL obtained from blood samples drawn either in citrate or citrate plus corn trypsin inhibitor (CTI) tubes. CTI is an inhibitor of FXIIa. Calibrated automated thrombogram (CAT) was performed without addition of any trigger. Results: We observed that plasma from patients with SLE had increased free nucleic acids (cfDNA in fluorescence units, controls: 94.90±21.29, SLE patients: 112.4±26.59; P=0.0211). In accordance with this observation, analyses by fluorescence microscopy showed that neutrophils from SLE patients, but not from controls, had NETs even in basal conditions. Moreover, neutrophils from these patients generated more NETs in presence of 100 nM PMA (Figure 1). To evaluate whether the increment of NETs observed in patients with SLE had consequences on the hemostasis of these patients, we tested thrombin generation of neutrophils from either patients with SLE or controls in the presence of platelets from healthy controls. Neutrophils from patients with SLE produced more thrombin than those from healthy controls under basal conditions and after stimulation with 100 nM PMA. These increments were avoided when PRP was collected from blood samples drawn with CTI (Figure 2). Conclusions: Neutrophils from SLE patients without antiphospholipid antibodies and with no history of thrombotic seemed more prone to form NETs than those from healthy controls. NETs might be considered as a key element in the prothrombotic profile of patients with SLE and their analyses by thrombin generation test might be useful to detect risk of occurrence of thrombotic events in these patients and to prevent its occurrence by therapeutic management. This work was supported by grants from FIS-FONDOS FEDER (PI19/00772). EMM holds a predoctoral fellowship from Fundación Española de Trombosis y Hemostasia (FETH-SETH). Disclosures Fernandez-Bello: Stago: Speakers Bureau; Pfizer: Speakers Bureau; SOBI,: Research Funding; Roche: Speakers Bureau; Novartis: Speakers Bureau; Takeda: Research Funding, Speakers Bureau; NovoNordisk: Current Employment, Research Funding, Speakers Bureau. Justo Sanz:Takeda: Current Employment. Alvarez Román:Bayer: Consultancy; Grifols: Research Funding; Pfizer,: Research Funding, Speakers Bureau; SOBI,: Consultancy, Research Funding, Speakers Bureau; Takeda: Research Funding, Speakers Bureau; NovoNordisk,: Research Funding, Speakers Bureau; Roche: Speakers Bureau; Novartis: Speakers Bureau. García Barcenilla:Novartis: Speakers Bureau; Roche: Speakers Bureau; Pfizer,: Speakers Bureau; NovoNordisk: Research Funding, Speakers Bureau; Takeda: Research Funding, Speakers Bureau; Bayer: Speakers Bureau. Canales:Sandoz: Speakers Bureau; Roche: Honoraria; Sandoz: Honoraria; Karyopharm: Honoraria; Roche: Speakers Bureau; Takeda: Speakers Bureau; Roche: Honoraria; Takeda: Speakers Bureau; Novartis: Honoraria; Sandoz: Speakers Bureau; Karyopharm: Honoraria; Roche: Speakers Bureau; Janssen: Honoraria; Janssen: Speakers Bureau; iQone: Honoraria; Sandoz: Honoraria; Gilead: Honoraria; Janssen: Speakers Bureau; Celgene: Honoraria; Janssen: Honoraria; Novartis: Honoraria. Jimenez-Yuste:F. Hoffman-La Roche Ltd, Novo Nordisk, Takeda, Sobi, Pfizer: Consultancy; F. Hoffman-La Roche Ltd, Novo Nordisk, Takeda, Sobi, Pfizer, Grifols, Octapharma, CSL Behring, Bayer: Honoraria; Grifols, Novo Nordisk, Takeda, Sobi, Pfizer: Research Funding. Butta:Novartis: Speakers Bureau; NovoNordisk: Speakers Bureau; Takeda: Research Funding, Speakers Bureau; SOBI: Speakers Bureau; Grifols: Research Funding; ROCHE: Research Funding, Speakers Bureau; Pfizer: Speakers Bureau.


Blood ◽  
2014 ◽  
Vol 124 (21) ◽  
pp. 4215-4215
Author(s):  
Christina K Baumgartner ◽  
Jonathan C Roberts ◽  
Paula M Jacobi ◽  
Sandra L Haberichter ◽  
Qizhen Shi ◽  
...  

Abstract Monitoring the correction of abnormal bleeding tendencies during the treatment of patients with hemostatic disorders is essential to evaluate success of therapy. While single clotting factor assays provide valuable information, global coagulation assays are desirable to better understand the overall hemostatic condition of patients. In Hemophilia A, severity of the clotting defect is traditionally evaluated by determining FVIII activity using chromogenic or clotting assays. Evaluation of thrombin generation in plasma samples for the assessment of bleeding tendencies in hemophilic patients has been suggested. Discriminating between samples with FVIII levels below 1%, however, has been challenging using FVIII activity and thrombin generation assays. We previously reported a native whole blood thrombin generation assay (nWB-TGA) that uses recalcification of whole blood samples without the addition of tissue factor to initiate clotting. We have shown that this assay is sensitive to varying levels of FVIII in vitroand to platelet targeted FVIII gene therapy in a murine model of Hemophilia A. The objective of the present study was to determine if the nWB-TGA can be used to monitor Hemophilia A patients during FVIII therapy and if this assay allows discrimination of whole blood samples with FVIII levels below 1%. Using the nWB-TGA we evaluated thrombin generation in a severe hemophilia A patient carrying an intron 22 inversion. Numerous data points were obtained from 15 different FVIII infusions, each targeting a FVIII level of 50%. Samples collected at least 72 hours (hrs) post infusion (>6 half-lives, calculated FVIII levels <1%) significantly differed from healthy control samples in all thrombin generation parameters. Compared with healthy controls (6.9 ± 0.6 min; mean ± SEM) the hemophilic patient had a lag time (LT) of 24.8 ± 3.4 min. Peak time in healthy controls and the patient was 10.1 ± 1 min and 35 ± 5 min, peak thrombin was 528 ± 78 nM and 124 ± 20 nM, endogenous thrombin potential (ETP) was 1949 ± 117 nM and 1201 ± 50 nM, and thrombin generation rate was 196 ± 58 nM/min and 21 ± 6 nM/min, respectively. While previous studies on thrombin generation in plasma samples mainly reported on differences in peak thrombin and ETP, spiking of hemophilic blood with increasing concentration of recombinant FVIII in vitro revealed that the LT was FVIII dose dependent in our assay. When hemophilic blood was reconstituted with FVIII to a 2%, 5% and 50% level, the LT was 22.5 ± 1.6 min, 16.1 ± 1.7 min and 8.8 ± 0.6 min, respectively. All other thrombin generation parameters were FVIII dose dependent as well. A FVIII dependent LT was also apparent in vivo, when we monitored the patient after FVIII infusions. LT was 6.4 ± 0.2 min at 15 min, 8.5 ± 0.4 min at 24 hrs, and 13.8 ± 0.5 min at 48 hrs post FVIII treatment. We identified the lack of tissue factor as being key to a FVIII dose dependent LT. At all post infusion time points the LT was approximately 5 min when tissue factor was added to the assay. To our surprise, looking at specific time points equal to or greater than 72 hrs post infusion enabled us to discriminate these samples based on the LT (72 hrs: LT= 13.0 ± 0.6 min, 84 hrs: LT= 19.5 ± 0.8 min, 96 hrs: 36.0 ± 4.4 min). The ETP, commonly used as a variable parameter in previous thrombin generation reports, however, was not different among 72, 84 and 96 hrs post FVIII infusion samples. Strikingly, FVIII activity determined by chromogenic and one stage clotting assay was below detection limit (1% FVIII:C) in samples obtained 72 hrs post infusion or later. Thus, the patient in our study displayed considerable thrombin generation determined by the nWB-TGA at post FVIII infusion time points when FVIII levels were considered undetectable with currently available technology. Our data suggest that the different LT observed in 72, 84 and 94 hrs post infusion samples is possibly related to differences in residual FVIII levels below 1%. In conclusion, the nWB-TGA provides a useful tool to monitor efficacy of FVIII replacement therapy and might assist in tailoring individual FVIII treatment regimens. This close to physiological whole blood assay allows distinguishing blood samples with FVIII levels below 1% in vivo, and might help to explain the heterogeneity in bleeding phenotypes observed in severe hemophilia A patients. This assay may also be useful in assessing therapeutic benefit of “long acting” FVIII or FIX products. Disclosures No relevant conflicts of interest to declare.


2009 ◽  
Vol 55 (3) ◽  
pp. 505-512 ◽  
Author(s):  
Charles Thuerlemann ◽  
André Haeberli ◽  
Lorenzo Alberio

Abstract Background: Complete investigation of thrombophilic or hemorrhagic clinical presentations is a time-, apparatus-, and cost-intensive process. Sensitive screening tests for characterizing the overall function of the hemostatic system, or defined parts of it, would be very useful. For this purpose, we are developing an electrochemical biosensor system that allows measurement of thrombin generation in whole blood as well as in plasma. Methods: The measuring system consists of a single-use electrochemical sensor in the shape of a strip and a measuring unit connected to a personal computer, recording the electrical signal. Blood is added to a specific reagent mixture immobilized in dry form on the strip, including a coagulation activator (e.g., tissue factor or silica) and an electrogenic substrate specific to thrombin. Results: Increasing thrombin concentrations gave standard curves with progressively increasing maximal current and decreasing time to reach the peak. Because the measurement was unaffected by color or turbidity, any type of blood sample could be analyzed: platelet-poor plasma, platelet-rich plasma, and whole blood. The test strips with the predried reagents were stable when stored for several months before testing. Analysis of the combined results obtained with different activators allowed discrimination between defects of the extrinsic, intrinsic, and common coagulation pathways. Activated protein C (APC) predried on the strips allowed identification of APC-resistance in plasma and whole blood samples. Conclusions: The biosensor system provides a new method for assessing thrombin generation in plasma or whole blood samples as small as 10 μL. The assay is easy to use, thus allowing it to be performed in a point-of-care setting.


2020 ◽  
Vol 35 (8) ◽  
pp. 1309-1316
Author(s):  
Fahimeh Akbarian ◽  
Mohammad Amin Tabatabaiefar ◽  
Vahid Shaygannejad ◽  
Mohammad Mahdi Shahpouri ◽  
Negin Badihian ◽  
...  

2021 ◽  
Author(s):  
Olga Lucia Herrán Ramírez ◽  
Huarrisson Azevedo Santos ◽  
Patrícia Gonzaga Paulino ◽  
Carolina Soares van der Meer ◽  
José Luis Rodríguez Bautista ◽  
...  

Abstract A cross-sectional study was conducted in Colombia to recover Brucella spp. DNA from bovine whole-blood samples through probe-based real-time PCR (Probe-qPCR) and by an SNP-based assay, differentiating vaccine strains from field strains. The associated factors for the presence of Brucella-DNA were reported and evaluated using logistical regression models. A total of 656 random cows from 40 herds were selected. Template DNA was obtained based on a modified salting-out protocol. The Probe- qPCR assay using bcsp31 gene amplification showed an efficiency of 92.35%, with a slope of -3.52 reached in the standard curve. The qPCR assay detected 9.5% (n = 62/656; 95% CI: 7.3,12.0) of the animals with Brucella-DNA presence, and 62.5% (n = 25/40; 95% CI: 45.8,77.3) of the herds with Brucella-DNA presence. Using the SNP-based assay, all positive samples were identified as field Brucella strains. In the final regression model at the animal-level, five variables were associated with Brucella-DNA presence: the use of bulls for mating, recorded history of reproductive problems, pregnant cows, parlor milking, and cows belonging to farms ≤ 200 m from the main road. At the herd-level, two variables were associated with Brucella-DNA presence: recorded history of reproductive problems and bulls' use for mating. Given the fluctuant brucellosis prevalence in endemic areas, updated epidemiological studies are necessary to evaluate the disease dynamic, and if established prevention and control measures have been effective or need to be adjusted. The increase in the prevalence of brucellosis in animal reservoirs creates an important risk of transmission in humans.


2010 ◽  
Vol 41 (02) ◽  
Author(s):  
N Shazi ◽  
A Böss ◽  
HJ Merkel ◽  
F Scharbert ◽  
D Hannak ◽  
...  

Separations ◽  
2021 ◽  
Vol 8 (6) ◽  
pp. 78
Author(s):  
Sevasti Karampela ◽  
Jessica Smith ◽  
Irene Panderi

An ever-increasing need exists within the forensic laboratories to develop analytical processes for the qualitative and quantitative determination of a broad spectrum of new psychoactive substances. Phenylethylamine derivatives are among the major classes of psychoactive substances available on the global market and include both amphetamine analogues and synthetic cathinones. In this work, an ultra-high-performance liquid chromatography-positive ion electrospray ionization tandem mass spectrometric method (UHPLC-ESI-MS/MS) has been developed and fully validated for the determination of 19 psychoactive substances, including nine amphetamine-type stimulants and 10 synthetic cathinone derivatives, in premortem and postmortem whole blood. The assay was based on the use of 1 mL premortem or postmortem whole blood, following solid phase extraction prior to the analysis. The separation was achieved on a Poroshell 120 EC-C18 analytical column with a gradient mobile phase of 0.1% formic acid in acetonitrile and 0.1% formic acid in water in 9 min. The dynamic multiple reaction monitoring used in this work allowed for limit of detection (LOD) and lower limit of quantitation (LOQ) values of 0.5 and 2 ng mL−1, respectively, for all analytes both in premortem and postmortem whole blood samples. A quadratic calibration model was used for the 12 quantitative analytes over the concentration range of 20–2000 ng mL−1, and the method was shown to be precise and accurate both in premortem and postmortem whole blood. The method was applied to the analysis of real cases and proved to be a valuable tool in forensic and clinical toxicology.


Sign in / Sign up

Export Citation Format

Share Document