Wick Technique: Reference Method for Implanted Glucose Sensors

2008 ◽  
Vol 13 (5) ◽  
pp. 453-457 ◽  
Author(s):  
Uwe Fischer ◽  
Rainer Ertle ◽  
Kerstin Rebrin ◽  
Ernst-Joachim Freyse
Author(s):  
Lorna K. Mayo ◽  
Kenneth C. Moore ◽  
Mark A. Arnold

An implantable artificial endocrine pancreas consisting of a glucose sensor and a closed-loop insulin delivery system could potentially replace the need for glucose self-monitoring and regulation among insulin dependent diabetics. Achieving such a break through largely depends on the development of an appropriate, biocompatible membrane for the sensor. Biocompatibility is crucial since changes in the glucose sensors membrane resulting from attack by orinter action with living tissues can interfere with sensor reliability and accuracy. If such interactions can be understood, however, compensations can be made for their effects. Current polymer technology offers several possible membranes that meet the unique chemical dynamics required of a glucose sensor. Two of the most promising polymer membranes are polytetrafluoroethylene (PTFE) and silicone (Si). Low-voltage scanning electron microscopy, which is an excellent technique for characterizing a variety of polymeric and non-conducting materials, 27 was applied to the examination of experimental sensor membranes.


1994 ◽  
Vol 72 (01) ◽  
pp. 084-088 ◽  
Author(s):  
E M Duncan ◽  
C R Casey ◽  
B M Duncan ◽  
J V Lloyd

SummaryThe aim of this study was to determine whether the concentration of trisodium citrate used to anticoagulate blood has an effect on the INR of the sample and the ISI of the thromboplastin. Five thromboplastins including and Australian reference material were used to measure the prothrombin time of normal and patient samples collected into two concentrations of trisodium citrate - 109 mM and 129 mM. There was no effect of citrate concentration on the INRs determined with the reference material. However for the other four thromboplastins there was a significant difference between INRs for the two citrate groups. The prothrombin times of the samples collected into 129 mM were longer than those collected into 109 mM. This difference was only slight in normal plasma but more marked in patients receiving oral anticoagulants, causing the INRs for patient plasmas collected into 129 mM citrate to be higher then the corresponding samples collected into 109 mM citrate.From orthogonal regression of log prothrombin times by the reference method against each thromboplastin, we found that the ISI for each thromboplastin was approximately 10% lower when determined with samples collected into 129 mM citrate than with samples collected into 109 mM. These results suggest that the concentration of trisodium citrate used for collection of blood samples can affect the calculation of the INR and the calibration of the ISI of thromboplastin. This was found both for commercial thromboplastins prepared by tissue extraction and for a recombinant tissue factor.


1983 ◽  
Vol 50 (04) ◽  
pp. 881-884 ◽  
Author(s):  
J T Christenson ◽  
P Qvarfordt ◽  
S-E Strand ◽  
D Arvidsson ◽  
T Sjöberg ◽  
...  

SummaryThrombogenicity of graft material is involved in early graft failure in small diameter grafts. The frequently seen postoperative swelling of the leg after distal revascularization may cause an increased intramuscular pressure and early graft failure.Pairs of 4 mm polytetrafluoroethylene (PTFE) grafts were implanted. Autologous platelets were labeled with mIn-oxine. Platelet adhesiveness onto the grafts were analyzed from gamma camera images. Intramuscular pressures were measured with wick technique. Blood flow was measured. One graft served as control the other as test graft. Ninety minutes after declamping the i. m. pressure was increased in the test-leg to 30 mmHg, and later to 60 mmHg.In the control-graft platelet uptake increased to a maximum 60 min after declamping. Blood flow and i.m. pressure remained uneffected. The test-grafts were initially similar but when i.m. pressure was increased to 30 mmHg activity in the grafts increased significantly. Blood flow decreased with 12% of initial flow. When i. m. pressure was raised to 60 mmHg platelet uptake continued to increase.An increased intramuscular pressure of 30 mmHg or more significantly increase the amount of platelets adhering onto PTFE grafts, emphasizing the need for measuring intramuscular pressures after lower limb vascular revascularizations.


2017 ◽  
Vol 20 (1) ◽  
pp. 22-27
Author(s):  
O. Tsakanyan ◽  
◽  
V. Goloshchapov ◽  
S. Koshel ◽  
N. Ganzha ◽  
...  
Keyword(s):  

2007 ◽  
Vol 3 (1) ◽  
pp. 89-113
Author(s):  
Zoltán Gillay ◽  
László Fenyvesi

There was a method developed that generates the three-dimensional model of not axisymmetric produce, based on an arbitrary number of photos. The model can serve as a basis for calculating the surface area and the volume of produce. The efficiency of the reconstruction was tested on bell peppers and artificial shapes. In case of bell peppers 3-dimensional reconstruction was created from 4 images rotated in 45° angle intervals. The surface area and the volume were estimated on the basis of the reconstructed area. Furthermore, a new and simple reference method was devised to give precise results for the surface area of bell pepper. The results show that this 3D reconstruction-based surface area and volume calculation method is suitable to determine the surface area and volume of definite bell peppers with an acceptable error.


2020 ◽  
pp. 3-14
Author(s):  
O. M. Samoylenko ◽  
O. V. Adamenko ◽  
B. P. Kukareka

Reference method for simultaneous calibration of the three and more measurement standards for vertical angle measurement is developed. This method can to use for obtaining the systematic biases of the vertical angles measurements for each of the measuring standards relative of the horizontal plain was averaged from measurement results in time their calibration or comparison. For realization of the reference method was developed the autocollimationel electronic measurement standard for the automatization measurement of the vertical angles SeaLineZero_Standard™ (SLZ_S™). Summary standard deviation (k=1) of the vertical angle measurement relative the horizontal plane, from the results of their calibration by reference method, is not more 0,07ʺ…0,15ʺ. This result was obtained without the use the systematic biases, for each measurement standards, as measurements corrections (with opposite sign). The measuring standards, that were developed and researched, are necessary for obtaining the systematic biases of the vertical angle measurement for total stations and theodolites, that have the normed standard error 0,5ʺ and 1ʺ, when these instruments are calibrating.


Sign in / Sign up

Export Citation Format

Share Document