scholarly journals Conflict and performance in research teams: how principal investigator can influence this relationship

2021 ◽  
Author(s):  
María‐José Foncubierta‐Rodríguez ◽  
Fernando Martín‐Alcázar ◽  
José‐Luis Perea‐Vicente
2020 ◽  
Author(s):  
Frank W. Pfrieger

AbstractAdvances in biomedicine and other fields of science and technology depend on research teams and their peer-reviewed publications. The scientific literature represents an invaluable socioeconomic resource guiding future research. Typically, this growing body of information is explored by queries in bibliographic databases concerning topics of interest and by subsequent scrutiny of matching publications. This approach informs readily about content, but leaves the workforce driving the field largely unexplored. The hurdle can be overcome by a transparent team-centered analysis that visualizes the teams working in a field of interest and that delineates their genealogic and collaborative relations. Context-specific, but citation-independent metrics gauge team impact and reveal key contributors valuing publication output, mentorship and collaboration. The new insight into the structure, dynamics and performance of the workforce driving research in distinct disciplines complements ongoing efforts to mine the scientific literature, foster collaboration, evaluate research and guide future policies and investments.


2018 ◽  
Vol 92 (7/8) ◽  
pp. 205-209
Author(s):  
Luc Quadackers ◽  
Marike Van Zanten

Based on the 2016 call for research proposals, six research projects were launched as a first beacon on the FAR research agenda, strengthening the collaboration between auditing academics and practitioners. During the second plenary session of the conference, representatives of two of the research teams presented initial insights of their studies. These presentations were provided by Therese Grohnert and Wim Gijselaers (concerning learning culture) and Anna Gold (regarding group audits). Furthermore, Olof Bik and Jan Bouwens, who are working on a FAR project in a so-called ‘joint working group’, presented their study onpartner incentives and performance. A summary of the findings of the three studies follows next, supplemented with a short overview of the discussion with the audience.


2021 ◽  
Vol 12 ◽  
Author(s):  
Feng Dong ◽  
Jian Peng ◽  
Xiao Wang ◽  
Minhui Tang

Cognitive diversity is an important concept stemming from western management research in the 1990s. With the rapid development of science and technology, there is a growing interest in the composition of an academic research team, such as team diversity. However, there is no tool available for measuring team cognitive diversity (TCD) for academic research teams. Based on Van der Vegt’s theoretical model of TCD, an Academic Research Team Cognitive Diversity Scale (ATCDS) is developed and validated for an academic research team in our research with two studies (N=737). In Study One, in-depth interviews and panel discussions were conducted to generate a preliminary questionnaire. In Study Two, the questionnaire was administered among academic research teams. Exploratory factor analysis revealed four factors regarding cognitive diversity: (1) the way of thinking, (2) knowledge and skills, (3) the view of the world, and (4) beliefs about what is right and wrong. The factor structure was further validated by confirmatory factor analysis. Moreover, correlation and regression analyses showed that academic research TCD was positively related to team creativity (r =0.306, p <0.01) and performance (r =0.204, p <0.10). To sum up, our newly developed 15-item ATCDS is sufficiently reliable and valid to be used for understanding cognitive diversity among academic research teams.


2018 ◽  
Vol 92 (7/8) ◽  
pp. 205-209
Author(s):  
Luc Quadackers ◽  
Marike Van Zanten

Based on the 2016 call for research proposals, six research projects were launched as a first beacon on the FAR research agenda, strengthening the collaboration between auditing academics and practitioners. During the second plenary session of the conference, representatives of two of the research teams presented initial insights of their studies. These presentations were provided by Therese Grohnert and Wim Gijselaers (concerning learning culture) and Anna Gold (regarding group audits). Furthermore, Olof Bik and Jan Bouwens, who are working on a FAR project in a so-called ‘joint working group’, presented their study onpartner incentives and performance. A summary of the findings of the three studies follows next, supplemented with a short overview of the discussion with the audience.


Author(s):  
H. M. Thieringer

It has repeatedly been show that with conventional electron microscopes very fine electron probes can be produced, therefore allowing various micro-techniques such as micro recording, X-ray microanalysis and convergent beam diffraction. In this paper the function and performance of an SIEMENS ELMISKOP 101 used as a scanning transmission microscope (STEM) is described. This mode of operation has some advantages over the conventional transmission microscopy (CTEM) especially for the observation of thick specimen, in spite of somewhat longer image recording times.Fig.1 shows schematically the ray path and the additional electronics of an ELMISKOP 101 working as a STEM. With a point-cathode, and using condensor I and the objective lens as a demagnifying system, an electron probe with a half-width ob about 25 Å and a typical current of 5.10-11 amp at 100 kV can be obtained in the back focal plane of the objective lens.


Author(s):  
Huang Min ◽  
P.S. Flora ◽  
C.J. Harland ◽  
J.A. Venables

A cylindrical mirror analyser (CMA) has been built with a parallel recording detection system. It is being used for angular resolved electron spectroscopy (ARES) within a SEM. The CMA has been optimised for imaging applications; the inner cylinder contains a magnetically focused and scanned, 30kV, SEM electron-optical column. The CMA has a large inner radius (50.8mm) and a large collection solid angle (Ω > 1sterad). An energy resolution (ΔE/E) of 1-2% has been achieved. The design and performance of the combination SEM/CMA instrument has been described previously and the CMA and detector system has been used for low voltage electron spectroscopy. Here we discuss the use of the CMA for ARES and present some preliminary results.The CMA has been designed for an axis-to-ring focus and uses an annular type detector. This detector consists of a channel-plate/YAG/mirror assembly which is optically coupled to either a photomultiplier for spectroscopy or a TV camera for parallel detection.


Author(s):  
Joe A. Mascorro ◽  
Gerald S. Kirby

Embedding media based upon an epoxy resin of choice and the acid anhydrides dodecenyl succinic anhydride (DDSA), nadic methyl anhydride (NMA), and catalyzed by the tertiary amine 2,4,6-Tri(dimethylaminomethyl) phenol (DMP-30) are widely used in biological electron microscopy. These media possess a viscosity character that can impair tissue infiltration, particularly if original Epon 812 is utilized as the base resin. Other resins that are considerably less viscous than Epon 812 now are available as replacements. Likewise, nonenyl succinic anhydride (NSA) and dimethylaminoethanol (DMAE) are more fluid than their counterparts DDSA and DMP- 30 commonly used in earlier formulations. This work utilizes novel epoxy and anhydride combinations in order to produce embedding media with desirable flow rate and viscosity parameters that, in turn, would allow the medium to optimally infiltrate tissues. Specifically, embeding media based on EmBed 812 or LX 112 with NSA (in place of DDSA) and DMAE (replacing DMP-30), with NMA remaining constant, are formulated and offered as alternatives for routine biological work.Individual epoxy resins (Table I) or complete embedding media (Tables II-III) were tested for flow rate and viscosity. The novel media were further examined for their ability to infilftrate tissues, polymerize, sectioning and staining character, as well as strength and stability to the electron beam and column vacuum. For physical comparisons, a volume (9 ml) of either resin or media was aspirated into a capillary viscocimeter oriented vertically. The material was then allowed to flow out freely under the influence of gravity and the flow time necessary for the volume to exit was recored (Col B,C; Tables). In addition, the volume flow rate (ml flowing/second; Col D, Tables) was measured. Viscosity (n) could then be determined by using the Hagen-Poiseville relation for laminar flow, n = c.p/Q, where c = a geometric constant from an instrument calibration with water, p = mass density, and Q = volume flow rate. Mass weight and density of the materials were determined as well (Col F,G; Tables). Infiltration schedules utilized were short (1/2 hr 1:1, 3 hrs full resin), intermediate (1/2 hr 1:1, 6 hrs full resin) , or long (1/2 hr 1:1, 6 hrs full resin) in total time. Polymerization schedules ranging from 15 hrs (overnight) through 24, 36, or 48 hrs were tested. Sections demonstrating gold interference colors were collected on unsupported 200- 300 mesh grids and stained sequentially with uranyl acetate and lead citrate.


Author(s):  
D. E. Newbury ◽  
R. D. Leapman

Trace constituents, which can be very loosely defined as those present at concentration levels below 1 percent, often exert influence on structure, properties, and performance far greater than what might be estimated from their proportion alone. Defining the role of trace constituents in the microstructure, or indeed even determining their location, makes great demands on the available array of microanalytical tools. These demands become increasingly more challenging as the dimensions of the volume element to be probed become smaller. For example, a cubic volume element of silicon with an edge dimension of 1 micrometer contains approximately 5×1010 atoms. High performance secondary ion mass spectrometry (SIMS) can be used to measure trace constituents to levels of hundreds of parts per billion from such a volume element (e. g., detection of at least 100 atoms to give 10% reproducibility with an overall detection efficiency of 1%, considering ionization, transmission, and counting).


1986 ◽  
Vol 50 (5) ◽  
pp. 264-267 ◽  
Author(s):  
GH Westerman ◽  
TG Grandy ◽  
JV Lupo ◽  
RE Mitchell

Sign in / Sign up

Export Citation Format

Share Document