Numerical Investigation of the Steady-State Operation of a Cylindrical Capillary Pumped Loop Evaporator

2003 ◽  
Vol 125 (2) ◽  
pp. 251-260 ◽  
Author(s):  
Y. H. Yan ◽  
J. M. Ochterbeck

A cylindrical capillary pumped loop evaporator operating under steady-state conditions was studied using a two-dimensional numerical model. Parameters affecting the phase conditions in the wick structure and thermal-fluid behavior in the evaporator liquid core were studied. The influences of heat load, liquid subcooling, and effective thermal conductivity of the wick structure were specifically selected to evaluate evaporator performance. Either increasing the applied heat flux and/or degree of inlet liquid subcooling resulted in decreased liquid core temperature, which is favorable for proper evaporator operation. This helps prevent conditions that may allow vapor formation in the liquid core as well as result in decreased length of the two-phase region in the wick structure. Decreasing the effective thermal conductivity of the wick also decreases the temperature in the liquid core. For a given liquid subcooling, a minimum heat flux exists below which vapor will generate in the liquid core and render the evaporator nonoperational. Additionally, for a given heat flux, a minimum required liquid subcooling exists as conditions are such that vapor potentially may form in the liquid core when the liquid subcooling is less than a minimum value.

2000 ◽  
Author(s):  
Y. H. Yan ◽  
J. M. Ochterbeck

Abstract A two-dimensional numerical model was established to study the behavior of a cylindrical capillary pumped loop evaporator under steady-state operations. The influence of heat load, liquid subcooling and effective thermal conductivity of the wick structure on the evaporator performance were studied. It was found that increasing the applied heat flux and degree of liquid subcooling resulted in a decrease the temperature in the liquid core. This helped to prevent the vapor from generating in the liquid core and decreased the length of the two phase region in the wick structure. Decreasing the effective thermal conductivity also decreases the temperature in the liquid core as related to the back wick condition. It was observed that for a given liquid subcooling, a minimum heat flux exists below which vapor will generate in the liquid core and render the evaporator non-operational. It was also observed that for a given heat flux, a minimum required liquid subcooling exists. Vapor may form in the liquid core when the liquid subcooling is less than the minimum value.


1971 ◽  
Vol 45 (4) ◽  
pp. 759-768 ◽  
Author(s):  
M. M. R. Williams

The effect of a temperature gradient in a gas inclined at an angle to a boundary wall has been investigated. For an infinite half-space of gas it is found that, in addition to the conventional temperature slip problem, the component of the temperature gradient parallel to the wall induces a net mass flow known as thermal creep. We show that the temperature slip and thermal creep effects can be decoupled and treated quite separately.Expressions are obtained for the creep velocity and heat flux, both far from and at the boundary; it is noted that thermal creep tends to reduce the effective thermal conductivity of the medium.


2000 ◽  
Vol 123 (1) ◽  
pp. 63-64 ◽  
Author(s):  
S. S. Sazhin ◽  
V. A. Gol'dshtein ◽  
M. R. Heikal

Newton's law of cooling is shown to underestimate the heat flux between a spherical body (droplet) and a homogeneous gas after this body is suddenly immersed into the gas. This problem is rectified by replacing the gas thermal conductivity by the effective thermal conductivity. The latter reduces to the gas thermal conductivity in the limit of t→∞, but can be substantially higher in the limit of t→0. In the case of fuel droplet heating in a medium duty truck Diesel engine the gas thermal conductivity may need to be increased by more than 100 percent at the initial stage of calculations to account for transient effects during the process of droplet heating.


1995 ◽  
Vol 117 (1) ◽  
pp. 75-81 ◽  
Author(s):  
A. K. Mallik ◽  
G. P. Peterson

An experimental investigation of vapor deposited micro heat pipe arrays was conducted using arrays of 34 and 66 micro heat pipes occupying 0.75 and 1.45 percent of the cross-sectional area, respectively. The performance of wafers containing the arrays was compared with that of a plain silicon wafer. All of the wafers had 8 × 8 mm thermofoil heaters located on the bottom surface to simulate the active devices in an actual application. The temperature distributions across the wafers were obtained using a Hughes Probeye TVS Infrared Thermal Imaging System and a standard VHS video recorder. For wafers containing arrays of 34 vapor deposited micro heat pipes, the steady-state experimental data indicated a reduction in the maximum surface temperature and temperature gradients of 24.4 and 27.4 percent, respectively, coupled with an improvement in the effective thermal conductivity of 41.7 percent. For wafers containing arrays of 66 vapor deposited micro heat pipes, the corresponding reductions in the surface temperature and temperature gradients were 29.0 and 41.7 percent, respectively, and the effective thermal conductivity increased 47.1 percent, for input heat fluxes of 4.70 W/cm2. The experimental results were compared with the results of a previously developed numerical model, which was shown to predict the temperature distribution with a high degree of accuracy, for wafers both with and without the heat pipe arrays.


2004 ◽  
Vol 7 (1) ◽  
pp. 129-138 ◽  
Author(s):  
J. C. Thoméo ◽  
M. V. A. Costa ◽  
J. F. Lopes Filho

2000 ◽  
Vol 122 (3) ◽  
pp. 450-459 ◽  
Author(s):  
T. J. Martin ◽  
G. S. Dulikravich

An inverse computational method has been developed for the nonintrusive and nondestructive evaluation of the temperature-dependence of thermal conductivity. The methodology is based on an inverse computational procedure that can be used in conjunction with an experiment. Given steady-state heat flux measurements or convection heat transfer coefficients on the surface of the specimen, in addition to a finite number of steady-state surface temperature measurements, the algorithm can predict the variation of thermal conductivity over the entire range of measured temperatures. Thus, this method requires only one temperature probe and one heat flux probe. The thermal conductivity dependence on temperature (k-T curve) can be completely arbitrary, although a priori knowledge of the general form of the k-T curve substantially improves the accuracy of the algorithm. The influence of errors of measured surface temperatures and heat fluxes on the predicted thermal conductivity has been evaluated. It was found that measurement errors of temperature up to five percent standard deviation were not magnified by this inverse procedure, while the effect of errors in measured heat fluxes were even lower. The method is applicable to two-dimensional and three-dimensional solids of arbitrary shape and size. [S0022-1481(00)01703-5]


2021 ◽  
Vol 2096 (1) ◽  
pp. 012165
Author(s):  
Yu P Zarichnyak ◽  
A Yu Gorbunova ◽  
V A Korablev ◽  
V A Ivanov ◽  
N V Pilipenko ◽  
...  

Abstract A model of a tube with a square cross-section was compiled for the mathematical analysis of the mesotube in Cartesian coordinates, with the selection of an element of a representative volume. To estimate the effective thermal conductivity of the structure, the generalized theory of conductivity with linearization of heat flux streamlines was used. The presence of anisotropy leads to the division of the problem into a separate estimate of the longitudinal and transverse thermal conductivity. The cross-section of the model was divided into elementary sections by a system of auxiliary adiabatic and isothermal planes, then the sections of the model were presented in the form of thermal resistances connected in chains - electrical circuits. Using the analogy of the identity of thermal and electrical resistances, the total conductivity of the sections and the effective thermal conductivity of the structure were determined. This methodology satisfies the test for limit transitions.


Author(s):  
Weilin Zhao ◽  
Jun Xu ◽  
Jinkai Li

Abstract The graphene oxide-deionized water (GO-DW) and graphene oxide-ethylence glycol (GO-EG) nanofluids were synthesized. The better suspension of nanofluids was achieved. The thermal conductivity of both nanofluids was analyzed. It indicates that GO nanoparticles can strengthen the thermal conductivity of DW base fluids by 22.6%–61.7% and EG base fluids by 15.3%–32.8%. Four copper heat pipes charged with GO-DW and GO-EG nanofluids as well as DW and EG base fluids were experimentally researched, it is discovered that the addition of GO nonoparticles in heat pipe can elevate the condenser wall temperature and reduce the temperature difference. Future analysis finds that, with respect to DW and EG fluids heat pipe, the thermal resistances of GO-DW and GO-EG nanofluids heat pipe are respectively decreased 42.6–52.4% and 31.9%–38.4% for air cooling, and 15.5–16.7% and 11.5%–18.9% for water cooling at condenser section. Besides, the wick structure of GO-DW nanofluids heat pipe was examined by Scanning Electron Microscope, and the effective thermal conductivity of fluid-wick combination was evaluated. The outcomes demonstrate that the evaporator wick surface contains about 0375–1.24μm coating film of GO nanoparticles. Assumed the coating film is 0.75μm, the effective thermal conductivity of fluid-wick combination is respectively enhanced by 66.92 % for GO-DW nonofluids heat pipe and 37.32% for GO-EG nonofluids heat pipe at 70 °C.


Sign in / Sign up

Export Citation Format

Share Document