Low-Velocity Subcooled Nucleate Flow Boiling at Various Orientations

1995 ◽  
Vol 117 (2) ◽  
pp. 380-386 ◽  
Author(s):  
K. M. Kirk ◽  
H. Merte ◽  
R. Keller

Subcooled forced convection nucleate boiling experiments with R-113 were conducted at low velocities using both thin film semitransparent gold-on-quartz and gold-coated copper substrate flat heaters at various orientations. The experiments demonstrate that if buoyancy is significant relative to bulk liquid momentum, then a decrease in the buoyant force normal to and away from the heater surface enhances the heat transfer, with the effect being greatest at low values of heat flux. Furthermore, the effect of the bulk liquid velocity is shown to be dependent on the surface orientation.

Author(s):  
A. Mukherjee

Flow boiling through microchannels is characterized by nucleation and growth of vapor bubbles that fills the entire channel cross-sectional area. As the bubble nucleates and grows inside the microchannel, a thin film of liquid or a microlayer gets trapped between the bubble and the channel walls. The heat transfer mechanism present at the channel walls during flow boiling is studied numerically. These mechanisms are compared to the heat transfer mechanisms present during nucleate boiling and in a moving evaporating meniscus. It is shown that the thermal and the flow fields present inside the microchannels around the bubbles are fundamentally different compared to nucleate boiling or in a moving evaporating meniscus. It is explained that how thin film evaporation is responsible for creating an apparent nucleate boiling heat transfer mechanism inside the microchannels.


2017 ◽  
Vol 139 (6) ◽  
Author(s):  
Viral K. Patel ◽  
Jamal Seyed-Yagoobi

This paper extends previous liquid film flow boiling studies by including the effect of an additional electrohydrodynamic (EHD) force, namely, the dielectrophoretic (DEP) force. Rather than using only EHD conduction pumping of the liquid film to electro-wet the heater surface, a localized nonuniform electric field above the heater surface is established to generate a DEP force for improved vapor bubble extraction during the nucleate boiling regime. The effects of liquid film height and applied potential are studied as a function of heater superheat and heat flux. A brief analytical study is also used to estimate the expected DEP force magnitude to explain the results. All of the above studies are also used to quantify the enhancement in heat transfer that can be achieved when heat transport systems are driven or augmented by these two EHD mechanisms. The results show remarkable enhancement of up to 1217% in boiling heat transfer coefficient at a given superheat when both mechanisms are used simultaneously. The experimental data are important for applications in thermal management in terrestrial and space conditions.


1993 ◽  
Vol 115 (1) ◽  
pp. 78-88 ◽  
Author(s):  
C. O. Gersey ◽  
I. Mudawar

The effects of chip protrusion on the forced-convection boiling and critical heat flux (CHF) of a dielectric coolant (FC-72) were investigated. The multi-chip module used in the present study featured a linear array of nine, 10 mm x 10 mm, simulated microelectronic chips which protruded 1 mm into a 20-mm wide side of a rectangular flow channel. Experiments were performed in vertical up flow with 5-mm and 2-mm channel gap thicknesses. For each configuration, the velocity and subcooling of the liquid were varied from 13 to 400 cm/s and 3 to 36° C, respectively. The nucleate boiling regime was not affected by changes in velocity and subcooling, and critical heat flux generally increased with increases in either velocity or subcooling. Higher single-phase heat transfer coefficients and higher CHF values were measured for the protruded chips compared to similar flush-mounted chips. However, adjusting the data for the increased surface area and the increased liquid velocity above the chip caused by the protruding chips yielded a closer agreement between the protruded and flush-mounted results. Even with the velocity and area adjustments, the most upstream protruded chip had higher single-phase heat transfer coefficients and CHF values for high velocity and/or highly-subcooled flow as compared the downstream protruded chips. The results show that, except for the most upstream chip, the performances of protruded chips are very similar to those of flush-mounted chips.


Author(s):  
Viral K. Patel ◽  
Jamal Seyed-Yagoobi

The research in this paper extends previous liquid film flow boiling studies by including the effect of an additional electrohydrodynamic (EHD) force, namely the dielectrophoretic (DEP) force. Rather than using only EHD conduction pumping of the liquid film to electro-wet the heater surface, a localized non-uniform electric field above the heater surface is also used to generate a dielectrophoretic force for improved vapor bubble extraction during the nucleate boiling regime. The effect of liquid film height and applied potential are studied as a function of heater superheat and heat flux. The study considers the sole and combined effect of DEP with EHD conduction pumping. A brief analytical study is also used to estimate the expected dielectrophoretic force magnitude and explain the results. All of the above studies are also used to quantify the enhancement in heat transfer that can be achieved when heat transport systems are driven or augmented by these electrohydrodynamic phenomena. The results show remarkable enhancement of up to 1217% in heat flux and boiling heat transfer coefficient for a given superheat when both mechanisms are used simultaneously. The experimental data are important for applications in thermal management in terrestrial and micro-gravity conditions.


1999 ◽  
Author(s):  
Yasuo Koizumi ◽  
Hiroyasu Ohtake ◽  
Manabu Mochizuki

Abstract The effect of solid particle introduction on subcooled-forced flow boiling heat transfer and a critical heat flux was examined experimentally. In the experiment, glass beads of 0.6 mm diameter were mixed in subcooled water. Experiments were conducted in a range of the subcooling of 40 K, a velocity of 0.17–6.7 m/s, a volumetric particle ratio of 0–17%. When particles were introduced, the growth of a superheated liquid layer near a heat trasnsfer surface seemed to be suppressed and the onset of nucleate boiling was delayed. The particles promoted the condensation of bubbles on the heat transfer surface, which shifted the initiation of a net vapor generation to a high heat flux region. Boiling heat trasnfer was augmented by the particle introduction. The suppression of the growth of the superheated liquid layer and the promotion of bubble condensation and dissipation by the particles seemed to contribute that heat transfer augmentation. The wall superheat at the critical heat flux was elevated by the particle introduction and the critical heat flux itself was also enhanced. However, the degree of the critical heat flux improvement was not drastic.


2021 ◽  
Author(s):  
Ji Hwan Lim ◽  
Minkyu Park

Abstract The onset of nucleate boiling (ONB) is the point at which the heat transfer mechanism in fluids changes and is one of the thermo-hydraulic factors that must be considered when establishing a cooling system operation strategy. Because the high heat flux of several MW/m2, which is loaded within a tokamak, is applied under a one-side heating condition, it is necessary to determine a correlative relation that can predict ONB under special heating conditions. In this study, the ONB of a one-side-heated screw tube was experimentally analyzed via a subcooled flow boiling experiment. The helical nut structure of the screw tube flow path wall allows for improved heat transfer performance relative to smooth tubes, providing a screw tube with a 53.98% higher ONB than a smooth tube. The effects of the system parameters on the ONB heat flux were analyzed based on the changes in the heat transfer mechanism, with the results indicating that the flow rate and degree of subcooling are proportional to the ONB heat flux because increasing these factors improves the forced convection heat transfer and increases the condensation rate, respectively. However, it was observed that the liquid surface tension and latent heat decrease as the pressure increases, leading to a decrease in the ONB heat flux. An evaluation of the predictive performance of existing ONB correlations revealed that most have high error rates because they were developed based on ONB experiments on micro-channels or smooth tubes and not under one-side high heat load conditions. To address this, we used dimensional analysis based on Python code to develop new ONB correlations that reflect the influence of system parameters.


Author(s):  
Jun Yeong Jung ◽  
Yong Hoon Jeong

In-Vessel Retention by External Reactor Vessel Cooling (IVR-ERVC) is method of removing the decay heat by cooling reactor vessel after corium relocation, and is also one of severe accident management strategies. Estimating heat transfer coefficients (HTCs) is important to evaluate heat transfer capability of the ERVC. In this study, the HTCs of outer wall of reactor vessel lower head were experimentally measured under the IVR-ERVC situation of Large Loss of Coolant Accident (LLOCA) condition. Experimental equipment was designed to simulate flow boiling condition of ERVC natural circulation, and based on APR+ design. This study focused on effects of real reactor vessel geometry (2.5 m of radius curvature) and material (SA508) for the HTCs. Curved rectangular water channel (test section) was design to simulate water channel which is between the reactor vessel lower head outer wall and thermal insulator. Radius curvature, length, width and gap size of the test section were respectively 2.5 m, 1 m, 0.07 m and 0.15 m. Two connection parts were connected at inlet and outlet of the test section to maintain fluid flow condition, and its cross section geometry was same with one of test section. To simulate vessel lower head outer wall, thin SA508 plate was used as main heater, and test section supported the main heater. Thickness, width, length and radius curvature of the main heater were 1.2 mm, 0.07 m, 1 m and 2.5 m respectively. The main heater was heated by DC rectifier, and applied heat flux was under CHF value. The test section was changed for each experiment. The HTCs of whole reactor vessel lower head (bottom: 0 ° and top: 90 °) were measured by inclining the test section, and experiments were conducted at four angular ranges; 0–22.5, 22.5–45, 45–67.5 and 67.5–90 °. DI water was used as working fluid in this experiment, and all experiments were conducted at 400 kg/m2s of constant mass flux with atmospheric pressure. The working fluid temperatures were measured at two point of water loop by K-type thermocouple. The main heater surface temperatures were measured by IR camera. The main heater was coated by carbon spray to make uniform surface emissivity, and the IR camera emissivity calibration was also conducted with the coated main heater. The HTCs were calculated by measured main heater surface temperature. In this research, the HTC results of 10, 30, 60 and 90 ° inclination angle were presented, and were plotted with wall super heat.


1997 ◽  
Vol 119 (4) ◽  
pp. 767-775 ◽  
Author(s):  
S. H. Najibi ◽  
H. Mu¨ller-Steinhagen ◽  
M. Jamialahmadi

Scale deposition on the heat transfer surfaces from water containing dissolved salts considerably reduces fuel economy and performance of the heat transfer equipment. In general, this problem is more serious during nucleate boiling due to the mechanisms of bubble formation and detachment. In this study, a large number of experiments were performed to determine the effect of fluid velocity, initial surface temperature, and bulk concentration on the rate of calcium carbonate deposition on heat transfer surfaces during subcooled flow boiling. A physically sound prediction model for the deposition process under these operating conditions has been developed which predicts the experimental data with good accuracy. Two previously published models are also discussed and used to predict the experimental data.


1995 ◽  
Vol 117 (2) ◽  
pp. 408-417 ◽  
Author(s):  
T. Oka ◽  
Y. Abe ◽  
Y. H. Mori ◽  
A. Nagashima

A series of pool boiling experiments have been conducted under reduced gravity condition (the order of 10−2 times the terrestrial gravity) available in an aircraft taking parabolic flight. A transparent resistant heater, a transparent indium oxide film plated on a glass plate, was employed so that the vapor/liquid behavior interacting with the heater surface could be observed from the rear side of the heater simultaneously with the side view of vapor bubbles above the heater surface. The experiments were performed for three different fluids—n-pentane, CFC-113, and water—under subcooled conditions. The critical heat fluxes for both n-pentane and CFC-113 under the reduced gravity were lowered to about 40 percent of the corresponding terrestrial values. Although the heat transfer characteristics in a low heat flux nucleate boiling regime for both n-pentane and CFC-113 showed no more than a slight change with the reduction in gravity, a significant heat transfer deterioration was noted with water in the reduced gravity boiling. The observation from the rear side of the heater suggested that this particular difference in the gravity dependency of heat transfer was ascribed to a considerable difference, between the organic fluids and water, in the behavior of attachment to the heater surface of the bubbles grown up, while the behavior of attachment must depend on the surface tension of each fluid and the wettability of the heater surface with the fluid.


Author(s):  
Hailei Wang ◽  
Richard Peterson

Flow boiling and heat transfer enhancement in four parallel microchannels using a dielectric working fluid, HFE 7000, was investigated. Each channel was 1000 μm wide and 510 μm high. A unique channel surface enhancement technique via diffusion bonding a layer of conductive fine wire mesh onto the heating wall was developed. According to the obtained flow boiling curves for both the bare and mesh channels, the amount of wall superheat was significantly reduced for the mesh channel at all stream-wise locations. This indicated that the nucleate boiling in the mesh channel was enhanced due to the increase of nucleation sites the mesh introduced. Both the nucleate boiling dominated and convective evaporation dominated regimes were identified. In addition, the overall trend for the flow boiling heat transfer coefficient, with respect to vapor quality, was increasing until the vapor quality reached approximately 0.4. The critical heat flux (CHF) for the mesh channel was also significantly higher than that of the bare channel in the low vapor quality region. Due to the fact of how the mesh was incorporated into the channels, no pressure drop penalty was identified for the mesh channels. Potential applications for this kind of mesh channel include high heat-flux electronic cooling systems and various energy conversion systems.


Sign in / Sign up

Export Citation Format

Share Document